York BHP024 manual Cooling Capacities 3 TON BHP036

Page 8

036-21528-003-A-0703

TABLE 5: COOLING CAPACITIES - 3 TON (BHP036)

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE OF AIR ON INDOOR COIL

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE AIR ON

 

 

1050 CFM

 

 

1200 CFM

 

 

OUTDOOR COIL

 

 

 

 

 

WB °F

 

 

 

WB °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

 

62

57

72

67

 

62

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

41.1

37.5

 

34.5

34.3

42.4

38.6

 

35.5

35.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

2.89

2.81

 

2.73

2.73

3.00

2.91

 

2.83

2.82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

 

86

25.6

32.3

 

34.5

34.3

28.2

35.5

 

35.5

35.3

 

MBH

 

DryEntering

°FBulb

 

83

22.5

29.3

 

33.5

33.6

24.7

32.0

 

35.5

35.3

 

 

 

 

 

 

 

 

 

85 °F

 

1

 

 

 

 

80

19.5

26.3

 

31.7

32.2

21.2

28.5

 

34.5

35.0

 

 

 

 

 

 

 

77

16.5

23.2

 

28.7

29.1

17.7

25.0

 

31.0

31.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

13.4

20.2

 

25.7

26.1

14.2

21.6

 

27.5

28.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

17.2

 

22.6

23.1

#N/A

18.1

 

24.0

24.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

14.1

 

19.6

20.0

#N/A

14.6

 

20.5

21.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

38.5

34.9

 

32.5

32.6

39.4

35.8

 

33.3

33.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

3.21

3.15

 

3.05

3.06

3.31

3.25

 

3.15

3.16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86

25.0

30.9

 

32.5

32.6

27.5

33.9

 

33.3

33.4

 

CapacitySensible

MBH

 

DryEntering

°FBulb

 

83

22.0

27.9

 

31.9

32.0

24.0

30.4

 

33.3

33.4

 

 

 

 

 

 

 

 

 

95 °F

 

1

 

 

 

 

80

19.0

24.8

 

30.5

30.6

20.5

26.9

 

33.0

33.1

 

 

 

 

 

 

 

77

15.9

21.8

 

27.5

27.5

17.0

23.4

 

29.5

29.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

12.9

18.8

 

24.4

24.5

13.5

19.9

 

26.0

26.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

15.7

 

21.4

21.5

#N/A

16.4

 

22.5

22.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

12.7

 

18.4

18.5

#N/A

12.9

 

19.0

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

35.6

32.1

 

29.5

30.4

36.4

32.8

 

30.2

31.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

3.61

3.52

 

3.44

3.45

3.70

3.61

 

3.53

3.54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

 

86

23.9

29.4

 

29.5

30.4

26.2

31.9

 

30.2

31.1

 

MBH

 

DryEntering

°FBulb

 

83

20.9

26.6

 

29.2

30.0

22.7

28.9

 

30.2

31.1

 

 

 

 

 

 

 

 

 

105 °F

 

1

 

 

 

 

80

17.9

23.6

 

27.8

28.6

19.2

25.4

 

30.0

30.8

 

 

 

 

 

 

 

77

14.8

20.5

 

24.8

25.5

15.7

21.9

 

26.5

27.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

11.8

17.5

 

21.8

22.5

12.2

18.4

 

23.0

23.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

14.5

 

18.7

19.5

#N/A

14.9

 

19.5

20.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

11.4

 

15.7

16.4

#N/A

11.4

 

16.0

16.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

32.6

29.3

 

26.5

28.2

33.3

29.9

 

27.0

28.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

4.01

3.88

 

3.83

3.84

4.10

3.97

 

3.91

3.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86

22.8

27.8

 

26.5

28.2

25.0

29.9

 

27.0

28.8

 

CapacitySensible

MBH

 

DryEntering

°FBulb

 

83

19.8

25.3

 

26.5

28.0

21.5

27.4

 

27.0

28.8

 

 

 

 

 

 

 

 

 

115 °F

 

1

 

 

 

 

80

16.8

22.3

 

25.2

26.5

18.0

23.9

 

27.0

28.5

 

 

 

 

 

 

 

77

13.7

19.2

 

22.2

23.5

14.5

20.4

 

23.5

25.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

10.7

16.2

 

19.1

20.5

11.0

16.9

 

20.0

21.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

13.2

 

16.1

17.4

#N/A

13.4

 

16.5

18.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

10.1

 

13.1

14.4

#N/A

9.9

 

13.0

14.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

29.7

26.4

 

23.5

26.0

30.2

26.9

 

23.9

26.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

4.41

4.25

 

4.21

4.22

4.49

4.33

 

4.29

4.30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

 

86

21.7

26.3

 

23.5

26.0

23.7

27.9

 

23.9

26.4

 

MBH

 

DryEntering

°FBulb

 

83

18.7

24.0

 

23.8

25.9

20.2

25.9

 

23.9

26.4

 

 

 

 

 

 

 

 

 

125 °F

 

1

 

 

 

 

80

15.7

21.0

 

22.6

24.5

16.7

22.4

 

24.1

26.2

 

 

 

 

 

 

 

77

12.6

17.9

 

19.5

21.5

13.2

18.9

 

20.6

22.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

9.6

14.9

 

16.5

18.4

9.7

15.4

 

17.1

19.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

11.9

 

13.5

15.4

#N/A

11.9

 

13.6

15.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#78

#N/A

8.8

 

10.4

12.4

#N/A

8.4

 

10.1

12.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.These capacities are net capacities - indoor fan heat deducted.

ALL SENSIBLE CAPACITY

8

Unitary Products Group

Image 8 Contents
Lower Installation Cost Operating EfficiencyOn Site Flexibility Utility Connections Made EasyCondensate PAN Condensate DrainDurable Finish Full Perimeter Base RailsLOW Maintenance Secured Service Access PortsEasy Service Access Replacement PartsTable of Contents Rectangle to Round AdaptersRoof Curbs Manual Outdoor DamperMBH COP Single Phase Three Phase Physical DataHSPF1 RATING2 Nominal Capacity KW BHP MBH Seer EEROutdoor Coil WB F Temperature of AIR on Indoor Coil Temperature AIR onCooling Capacities 2 TON BHP024 Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2-1/2 TON BHP030 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR FHeating Capacities 2 TON BHP024 Heating Capacities 3 TON BHP036 Heating Capacities 3-1/2 TON BHP042Heating Capacities 4 TON BHP048 Additional Static Resistance RESISTANCE, IWG Description CFMField Wiring Diagram Electrical Data Basic Unit Electrical Data 13 Seer Heat Pump / Electric Heat RLA LRAModel BHP B1HP Shipping Operating Corner Weights Unit SizeApplication Data Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Indoor Supply FAN Assembly Outdoor FAN AssemblyGeneral Description Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section 036-21528-003-A-0703 Unitary 5005 Norman Products York Group Drive 73069
Related manuals
Manual 28 pages 34.15 Kb