York BHP024 manual Field Wiring Diagram

Page 15

036-21528-003-A-0703

THERMOSTAT

** = Minimum wire size of 18 AWG

R

 

 

 

 

 

 

 

wire should be used for all field

 

 

 

 

 

 

installed 24 volt wire.

G

 

 

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROGRAMMABLE

 

 

 

 

 

 

 

THERMOSTAT ONLY

 

 

 

 

 

 

 

 

 

O

 

 

 

 

* = Only required on units with

 

 

 

 

 

C

 

 

 

supplemental electric heat.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT TERMINAL STRIP

 

**

R

NOTE:

 

 

HEAT ANTICIPATOR

 

G

SHOULD BE SET AT 0.25

 

AMPS FOR ALL MODELS

 

 

 

Y

 

*

W2

24 VOLT TRANSFORMER

W1

O

C

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

FIGURE 2 - FIELD WIRING DIAGRAM

Unitary Products Group

15

Image 15
Contents Utility Connections Made Easy Lower Installation CostOperating Efficiency On Site FlexibilityFull Perimeter Base Rails Condensate PANCondensate Drain Durable FinishReplacement Parts LOW MaintenanceSecured Service Access Ports Easy Service AccessManual Outdoor Damper Table of ContentsRectangle to Round Adapters Roof CurbsNominal Capacity KW BHP MBH Seer EER MBH COP Single Phase Three PhasePhysical Data HSPF1 RATING2Temperature of AIR on Indoor Coil Temperature AIR on Cooling Capacities 2 TON BHP024Outdoor Coil WB F Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR F Heating Capacities 2 TON BHP024Heating Capacities 2-1/2 TON BHP030 Heating Capacities 3-1/2 TON BHP042 Heating Capacities 3 TON BHP036Heating Capacities 4 TON BHP048 RESISTANCE, IWG Description CFM Additional Static ResistanceField Wiring Diagram Electrical Data Basic Unit RLA LRA Electrical Data 13 Seer Heat Pump / Electric HeatB1HP Shipping Operating Corner Weights Unit Size Application DataModel BHP Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Unit Cabinet Indoor Supply FAN AssemblyOutdoor FAN Assembly General DescriptionUnit Operating Characteristics Electric Heating SectionElectrical Requirements 036-21528-003-A-0703 Unitary 5005 Norman Products York Group Drive 73069
Related manuals
Manual 28 pages 34.15 Kb

BHP024 specifications

The York BHP024 is a robust and efficient air conditioning unit designed to meet the needs of residential and commercial spaces. As part of the York BHP series, this model is tailored for environments requiring reliable cooling solutions, ensuring occupant comfort across varied climate conditions.

One of the standout features of the York BHP024 is its high-efficiency rating. The unit employs advanced cooling technology that allows it to deliver exceptional performance while consuming less energy, making it an environmentally-friendly choice. With a seasonal energy efficiency ratio (SEER) that exceeds industry standards, the BHP024 not only helps in reducing electricity bills but also contributes to lower greenhouse gas emissions.

The unit is equipped with a variable speed compressor that intelligently adjusts its operation based on the cooling demand. This not only enhances comfort by maintaining consistent temperatures but also minimizes energy wastage. The compressor, paired with a high-efficiency evaporator coil, optimizes heat exchange processes, further improving overall performance.

In terms of build quality, the York BHP024 features a durable cabinet constructed from corrosion-resistant materials, ensuring longevity even in challenging weather conditions. The unit’s design includes sound-dampening technologies, resulting in quieter operation, which is particularly important for residential applications.

Another notable characteristic of this model is its user-friendly control interface. The BHP024 comes with a programmable thermostat, enabling users to customize their cooling preferences and schedule operations according to their lifestyles. This smart control capability aligns with modern energy management practices, making it easier for users to optimize comfort and efficiency.

Installation versatility is also a key benefit of the York BHP024. The unit can be configured in various setups, accommodating different indoor layouts and requirements. This flexibility ensures that customers can find a suitable installation method that works for their space.

In conclusion, the York BHP024 is a cutting-edge air conditioning solution characterized by efficiency, durability, and user-friendly technology. Its advanced features make it a top choice for those seeking reliable and effective cooling solutions, whether for residential or light commercial applications. With its combination of high performance and robust construction, the BHP024 stands out as an ideal option for anyone looking to enhance their indoor climate control.