York Cooling Capacities 2 TON BHP024, Temperature of AIR on Indoor Coil Temperature AIR on

Page 6

036-21528-003-A-0703

TABLE 3: COOLING CAPACITIES - 2 TON (BHP024)

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE OF AIR ON INDOOR COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEMPERATURE AIR ON

 

 

 

800 CFM

 

 

 

900 CFM

 

 

OUTDOOR COIL

 

 

 

 

 

WB °F

 

 

 

WB °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

 

62

57

72

67

 

62

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

29.1

26.0

 

23.8

23.4

29.7

26.6

 

24.3

23.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

1.93

1.91

 

1.88

1.87

1.95

1.93

 

1.91

1.90

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

 

86

19.2

23.1

 

23.8

23.4

20.9

25.1

 

24.3

23.9

 

MBH

 

DryEntering

°FBulb

 

83

16.9

20.8

 

23.8

23.4

18.3

22.5

 

24.3

23.9

 

 

 

 

 

 

 

 

 

85 °F

 

1

 

 

 

 

80

14.5

18.5

 

21.9

22.7

15.6

19.8

 

23.4

23.6

 

 

 

 

 

 

 

77

12.2

16.1

 

19.5

20.3

12.9

17.2

 

20.7

20.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

9.9

13.8

 

17.2

18.0

10.3

14.5

 

18.0

18.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

11.5

 

14.9

15.7

#N/A

11.9

 

15.4

15.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

9.1

 

12.5

13.3

#N/A

9.2

 

12.7

12.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

27.2

24.2

 

22.1

22.0

27.7

24.6

 

22.5

22.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

2.07

2.06

 

2.02

2.02

2.09

2.08

 

2.05

2.04

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86

18.6

22.3

 

22.1

22.0

20.1

23.7

 

22.5

22.4

 

CapacitySensible

MBH

 

DryEntering

°FBulb

 

83

16.2

20.0

 

22.1

22.0

17.5

21.5

 

22.5

22.4

 

 

 

 

 

 

 

 

 

95 °F

 

1

 

 

 

 

80

13.9

17.7

 

20.8

21.4

14.8

18.9

 

21.8

22.1

 

 

 

 

 

 

 

77

11.6

15.3

 

18.4

19.0

12.2

16.2

 

19.2

19.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

9.2

13.0

 

16.1

16.7

9.5

13.5

 

16.5

16.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

10.7

 

13.8

14.4

#N/A

10.9

 

13.8

14.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

8.3

 

11.4

12.0

#N/A

8.2

 

11.2

11.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

23.8

22.4

 

20.5

20.6

24.2

22.8

 

20.8

20.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

2.20

2.21

 

2.17

2.16

2.24

2.24

 

2.20

2.19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

 

86

19.5

21.5

 

20.5

20.6

20.4

22.3

 

20.8

20.9

 

MBH

 

DryEntering

°FBulb

 

83

17.2

19.2

 

20.5

20.6

18.5

20.7

 

20.8

20.9

 

 

 

 

 

 

 

 

 

105 °F

 

1

 

 

 

 

80

14.9

16.9

 

19.7

20.0

15.9

18.1

 

20.4

20.6

 

 

 

 

 

 

 

77

12.6

14.6

 

17.4

17.7

13.3

15.4

 

17.8

18.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

10.2

12.2

 

15.1

15.3

10.6

12.7

 

15.1

15.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

9.9

 

12.7

13.0

#N/A

10.1

 

12.4

12.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

7.6

 

10.4

10.7

#N/A

7.4

 

9.8

10.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

20.4

20.7

 

18.9

19.2

20.6

20.9

 

19.1

19.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

2.34

2.36

 

2.32

2.31

2.38

2.40

 

2.36

2.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

86

20.4

20.7

 

18.9

19.2

20.6

20.9

 

19.1

19.4

 

CapacitySensible

MBH

 

DryEntering

°FBulb

 

83

18.2

18.5

 

18.9

19.2

19.5

19.8

 

19.1

19.4

 

 

 

 

 

 

 

 

 

115 °F

 

1

 

 

 

 

80

15.9

16.1

 

18.7

18.6

17.0

17.3

 

19.0

19.1

 

 

 

 

 

 

 

77

13.6

13.8

 

16.4

16.3

14.4

14.6

 

16.4

16.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

11.2

11.5

 

14.1

14.0

11.7

11.9

 

13.7

13.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

9.1

 

11.7

11.6

#N/A

9.3

 

11.1

11.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

6.8

 

9.4

9.3

#N/A

6.6

 

8.4

8.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NET CAP. MBH

 

17.0

18.9

 

17.3

17.8

17.0

19.0

 

17.5

17.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER INPUT kW

 

2.47

2.51

 

2.46

2.45

2.52

2.56

 

2.51

2.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CapacitySensible

 

 

 

 

 

86

21.3

19.9

 

17.3

17.8

20.8

19.5

 

17.5

17.9

 

MBH

 

DryEntering

°FBulb

 

83

19.2

17.7

 

17.3

17.8

20.6

18.9

 

17.5

17.9

 

 

 

 

 

 

 

 

 

125 °F

 

1

 

 

 

 

80

16.9

15.4

 

17.7

17.3

18.1

16.5

 

17.6

17.7

 

 

 

 

 

 

 

77

14.6

13.0

 

15.4

15.0

15.4

13.8

 

15.0

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

74

12.2

10.7

 

13.1

12.6

12.8

11.1

 

12.3

12.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

71

#N/A

8.4

 

10.7

10.3

#N/A

8.5

 

9.7

9.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

68

#N/A

6.0

 

8.4

8.0

#N/A

5.8

 

7.0

7.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.These capacities are net capacities - indoor fan heat deducted.

ALL SENSIBLE CAPACITY

6

Unitary Products Group

Image 6 Contents
On Site Flexibility Lower Installation CostOperating Efficiency Utility Connections Made EasyDurable Finish Condensate PANCondensate Drain Full Perimeter Base RailsEasy Service Access LOW MaintenanceSecured Service Access Ports Replacement PartsRoof Curbs Table of ContentsRectangle to Round Adapters Manual Outdoor DamperHSPF1 RATING2 MBH COP Single Phase Three PhasePhysical Data Nominal Capacity KW BHP MBH Seer EERTemperature of AIR on Indoor Coil Temperature AIR on Cooling Capacities 2 TON BHP024Outdoor Coil WB F Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR F Heating Capacities 2 TON BHP024Heating Capacities 2-1/2 TON BHP030 Heating Capacities 3 TON BHP036 Heating Capacities 3-1/2 TON BHP042Heating Capacities 4 TON BHP048 Additional Static Resistance RESISTANCE, IWG Description CFMField Wiring Diagram Electrical Data Basic Unit Electrical Data 13 Seer Heat Pump / Electric Heat RLA LRAB1HP Shipping Operating Corner Weights Unit Size Application DataModel BHP Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply General Description Indoor Supply FAN AssemblyOutdoor FAN Assembly Unit CabinetUnit Operating Characteristics Electric Heating SectionElectrical Requirements 036-21528-003-A-0703 Unitary 5005 Norman Products York Group Drive 73069