York BHP024 manual Electrical Data Basic Unit

Page 16

036-21528-003-A-0703

TABLE 15: ELECTRICAL DATA (BASIC UNIT)

 

 

VOLTAGE

 

COMPRESSOR

OUTDOOR

SUPPLY AIR

MINIMUM

MAX

MAX.

UNIT

 

 

 

LIMITATIONS

1

HACR

 

MODEL

POWER

 

 

FAN

BLOWER

FUSE

TRANSFORMER

 

 

 

CIRCUIT

BREAKER

POWER

BHP

SUPPLY

 

 

 

 

 

MOTOR,

MOTOR,

SIZE,

SIZE (VA)

 

 

 

 

 

AMPACITY

SIZE,

FACTOR

 

 

MIN.

MAX.

RLA

LRA

FLA

FLA

AMPS2

 

 

 

 

AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

208/230-1-60

187

253

 

9.3

57.0

1.1

5.0

17.7

25

25

0.96

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-1-60

187

253

 

15.0

72.5

1.1

5.0

24.9

35

35

0.96

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

208/230-3-60

187

253

 

10.0

63.0

1.1

5.0

18.6

25

25

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-3-60

414

504

 

5.0

31.0

0.6

5.0

11.9

15

15

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-1-60

187

253

 

17.2

94.0

1.1

7.3

29.9

45

45

0.96

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

208/230-3-60

187

253

 

11.4

78.0

1.1

7.3

22.7

30

30

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-3-60

414

504

 

5.7

40.0

0.6

7.3

15.4

20

20

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-1-60

187

253

 

20.0

104.0

1.1

7.3

33.4

50

50

0.96

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

208/230-3-60

187

253

 

13.9

88.0

1.1

7.3

25.8

35

35

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-3-60

414

504

 

6.4

44.0

0.6

7.3

16.1

20

20

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-1-60

187

253

 

23.4

126.0

1.5

7.3

38.1

60

60

0.96

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

208/230-3-60

187

253

 

13.0

93.0

1.5

7.3

25.1

35

35

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460-3-60

414

504

 

6.4

46.5

0.8

7.3

16.3

20

20

0.96

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Rated in accordance with ARI Standard 100, utilization range “A”.

2.Dual element, time delay type.

 

NOMINAL VOLTAGE

VOLTAGE

KW CAP. MULTIPLIER

ELECTRIC HEAT

 

 

 

 

208

0.75

CORRECTION

240

230

0.92

FACTORS

 

 

 

 

 

480

460

0.92

 

 

 

 

16

Unitary Products Group

Image 16 Contents
Lower Installation Cost Operating EfficiencyOn Site Flexibility Utility Connections Made EasyCondensate PAN Condensate DrainDurable Finish Full Perimeter Base RailsLOW Maintenance Secured Service Access PortsEasy Service Access Replacement PartsTable of Contents Rectangle to Round AdaptersRoof Curbs Manual Outdoor DamperMBH COP Single Phase Three Phase Physical DataHSPF1 RATING2 Nominal Capacity KW BHP MBH Seer EERCooling Capacities 2 TON BHP024 Temperature of AIR on Indoor Coil Temperature AIR onOutdoor Coil WB F Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2 TON BHP024 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR FHeating Capacities 2-1/2 TON BHP030 Heating Capacities 3 TON BHP036 Heating Capacities 3-1/2 TON BHP042Heating Capacities 4 TON BHP048 Additional Static Resistance RESISTANCE, IWG Description CFMField Wiring Diagram Electrical Data Basic Unit Electrical Data 13 Seer Heat Pump / Electric Heat RLA LRAApplication Data B1HP Shipping Operating Corner Weights Unit SizeModel BHP Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Indoor Supply FAN Assembly Outdoor FAN AssemblyGeneral Description Unit CabinetElectric Heating Section Unit Operating CharacteristicsElectrical Requirements 036-21528-003-A-0703 Unitary 5005 Norman Products York Group Drive 73069