York BHP024 manual Physical Data, HSPF1 RATING2, Nominal Capacity KW BHP MBH Seer EER

Page 5

036-21528-003-A-0703

BACK AND BOTTOM

RETURN AIR

AND SUPPLY AIR

DUCT OPENING

HIGH VOLTAGE

TERMINAL BLOCK

LOW VOLTAGE

TERMINAL BLOCK

LONG-LASTING

POWDER PAINT

FINISH

HIGH-EFFICIENCY

COMPRESSOR

RIGIDLY

MOUNTED

DIRECT DRIVE

CONDENSER

FAN MOTOR

HIGHLY EFFICIENT ENHANCED COPPER TUBE/ALUMINUM FIN INDOOR COIL

HIGHLY EFFICIENT

ENHANCED COPPER

TUBE/ALUMINUM FIN

OUTDOOR COIL

DECORATIVE

PROTECTIVE

COIL GUARD

ECM DIRECT DRIVE BLOWER MOTOR WITH SLIDE-OUT BLOWER ASSEMBLY

HEAVY GAUGE

REMOVABLE

BASE RAILS

FIGURE 1 - UNIT CUT AWAY

TABLE 1: RATINGS

MODEL

COOLING CAPACITY1

 

SOUND

NET HEATING CAPACITY

AVAILABLE ELECTRIC HEAT

 

80 / 67-95°F

 

HSPF1

RATING2

@47°F

@17°F

NOMINAL CAPACITY KW

 

BHP

 

 

 

 

MBH

SEER

 

EER

 

(dbels)

MBH

COP

MBH

COP

SINGLE PHASE

THREE PHASE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024

24.4

13.0

 

11.3

7.6

79

21.8

3.40

11.0

2.00

5.0, 7.5, 10.0

N / A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

030

30.0

13.0

 

11.3

7.6

77

28.2

3.40

16.5

2.20

5.0, 7.5, 10.0, 15.0

10.0,

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

35.5

13.0

 

11.3

7.6

77

32.0

3.30

18.9

2.20

5.0, 7.5, 10.0, 15.0

10.0,

15.0

042

42.0

13.0

 

11.3

7.6

83

42.0

3.40

23.0

2.20

10.0, 15.0

10.0,

15.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

47.0

13.0

 

11.3

7.6

82

45.0

3.30

25.8

2.20

10.0, 15.0, 20.0, 25.0

10.0, 15.0,

20.0, 25.0

1.Certified in accordance with the Uniary Small Equipment certification program, which is based on ARI Standard 210/240.

2.Rated in accordance with ARI Standard 270.

SEER =Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

COP = Coefficient of Performance - the total heating capacity provided by the refrigeration system, including circulating fan heat but excluding supple- mentary resistance (BGU’s per hour) divided by the total electric input (watts) x 3.412.

TABLE 2: PHYSICAL DATA

 

MODELS

 

 

BHP

 

 

 

 

 

 

 

 

 

 

 

024

030

036

 

042

048

 

 

 

 

 

 

 

 

INDOOR

CENTRIFUGAL BLOWER (Dia. x Wd. in.)

10 X 8

10 X 8

11 x 10

 

11 x 10

11 X 10

BLOWER

FAN MOTOR HP (ECM)

1/2

1/2

3/4

 

3/4

3/4

 

 

 

 

 

 

 

 

INDOOR

ROWS DEEP

2

3

3

 

3

3

FINS PER INCH

15

13

15

 

16

16

COIL

 

FACE AREA (Sq. Ft.)

4.38

4.38

4.38

 

5.63

5.63

 

 

 

 

 

 

 

 

 

 

OUTDOOR

PROPELLER DIA. (in.)

22

22

22

 

22

22

FAN MOTOR HP

1/4

1/4

1/4

 

1/4

1/4

FAN

 

NOM. CFM TOTAL

1,800

1,800

2,400

 

2,400

3,000

 

 

 

 

 

 

 

 

 

 

OUTDOOR

ROWS DEEP

1

1

2

 

2

2

FINS PER INCH

20

20

20

 

20

20

COIL

 

FACE AREA (Sq. Ft.)

11.7

11.7

11.7

 

16.4

16.4

 

 

 

 

 

 

 

 

 

 

CHARGE

REFRIGERANT 22 (lbs./oz.)

5 / 5

5 / 15

8 / 4

 

9 / 14

12 / 0

 

 

 

 

 

 

 

 

FILTER

FACE AREA (Sq. Ft. / Qty. / Size)

 

4.28 / 2 / 14 x 22

 

 

 

 

 

 

 

 

 

 

COMPRESSOR

Hermetic Type, Qty. = 1

Reciprocating

Scroll

Scroll

 

Scroll

Scroll

 

 

 

 

 

 

 

 

Unitary Products Group

5

Image 5
Contents Operating Efficiency Lower Installation CostOn Site Flexibility Utility Connections Made EasyCondensate Drain Condensate PANDurable Finish Full Perimeter Base RailsSecured Service Access Ports LOW MaintenanceEasy Service Access Replacement PartsRectangle to Round Adapters Table of ContentsRoof Curbs Manual Outdoor DamperPhysical Data MBH COP Single Phase Three PhaseHSPF1 RATING2 Nominal Capacity KW BHP MBH Seer EEROutdoor Coil WB F Temperature of AIR on Indoor Coil Temperature AIR onCooling Capacities 2 TON BHP024 Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2-1/2 TON BHP030 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR FHeating Capacities 2 TON BHP024 Heating Capacities 3-1/2 TON BHP042 Heating Capacities 3 TON BHP036Heating Capacities 4 TON BHP048 RESISTANCE, IWG Description CFM Additional Static ResistanceField Wiring Diagram Electrical Data Basic Unit RLA LRA Electrical Data 13 Seer Heat Pump / Electric HeatModel BHP B1HP Shipping Operating Corner Weights Unit SizeApplication Data Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply Outdoor FAN Assembly Indoor Supply FAN AssemblyGeneral Description Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section 036-21528-003-A-0703 Unitary 5005 Norman Products York Group Drive 73069
Related manuals
Manual 28 pages 34.15 Kb

BHP024 specifications

The York BHP024 is a robust and efficient air conditioning unit designed to meet the needs of residential and commercial spaces. As part of the York BHP series, this model is tailored for environments requiring reliable cooling solutions, ensuring occupant comfort across varied climate conditions.

One of the standout features of the York BHP024 is its high-efficiency rating. The unit employs advanced cooling technology that allows it to deliver exceptional performance while consuming less energy, making it an environmentally-friendly choice. With a seasonal energy efficiency ratio (SEER) that exceeds industry standards, the BHP024 not only helps in reducing electricity bills but also contributes to lower greenhouse gas emissions.

The unit is equipped with a variable speed compressor that intelligently adjusts its operation based on the cooling demand. This not only enhances comfort by maintaining consistent temperatures but also minimizes energy wastage. The compressor, paired with a high-efficiency evaporator coil, optimizes heat exchange processes, further improving overall performance.

In terms of build quality, the York BHP024 features a durable cabinet constructed from corrosion-resistant materials, ensuring longevity even in challenging weather conditions. The unit’s design includes sound-dampening technologies, resulting in quieter operation, which is particularly important for residential applications.

Another notable characteristic of this model is its user-friendly control interface. The BHP024 comes with a programmable thermostat, enabling users to customize their cooling preferences and schedule operations according to their lifestyles. This smart control capability aligns with modern energy management practices, making it easier for users to optimize comfort and efficiency.

Installation versatility is also a key benefit of the York BHP024. The unit can be configured in various setups, accommodating different indoor layouts and requirements. This flexibility ensures that customers can find a suitable installation method that works for their space.

In conclusion, the York BHP024 is a cutting-edge air conditioning solution characterized by efficiency, durability, and user-friendly technology. Its advanced features make it a top choice for those seeking reliable and effective cooling solutions, whether for residential or light commercial applications. With its combination of high performance and robust construction, the BHP024 stands out as an ideal option for anyone looking to enhance their indoor climate control.