York BHP024 Condensate PAN, Condensate Drain, Durable Finish, Full Perimeter Base Rails, Controls

Page 2

CONDENSATE PAN

Anon-corrosive, long-lasting, water-tight pan is posi- tioned below the evaporator coil to collect and drain all condensate; less collection of stagnate condensate will build-up. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality).

CONDENSATE DRAIN

The heavy duty, inch NPTI copper connection is more tolerable during installation and is more durable over time. The connection is rigidly mounted to assure proper fit and leak tight seal.

DURABLE FINISH

With a heavy duty cabinet made of powder-painted, galvanized steel, the neutral color blends into sur- rounding areas. The powered paint provides a better paint to steel bond, which resists corrosion and rust creep. The special primer formulas and glossy earth tone finish insure less fading when exposed to sunlight and offers a more attractive on site appearance. This paint finish exceeds ASTM-B117 standards for 750 hours salt spray rating, the highest in the industry.

FULL PERIMETER BASE RAILS

The easily removable base rails provide a solid founda- tion for the entire unit and protects the unit during ship- ment. The rails provide fork lift access from all sides.

Rigging holes are, provided also so that an overhead crane can be used to place the unit on a roof. On appli- cations when the unit is placed on a pad, the base will keep the unit off the pad to deter corrosion. On applica- tions where height is limited, the 2-3/8 inch high base rails may be removed on location.

MORE ATTRACTIVE APPEARANCE

A single piece “Water Shed” top cover containing a top discharge condenser fan arrangement requires less square footage on installation and provides a wider variety of installations. The one piece design adds greater water integrity. Rounded corners with water drip edges add to the attractive appearance. The cabi- net panels have a non-fibrous insulation that reduces insulation fibers into conditioned area.

036-21528-003-A-0703

TOP DISCHARGE

The top discharge condenser fan does not disrupt neighboring areas and does not dry-out vegetation sur- rounding the unit. The warm air from the top mounted fan is blown up away from the structure and any land- scaping. This allows compact location on multi-unit applications.

OUTDOOR COIL GRILLE

Amulti-piece totally enclosed, rigidly mounted outdoor coil grille provides protection from objects and person- nel after installation. It also provides protection during transit and installation.

LOW OPERATING SOUND LEVEL

The upward air flow carries the normal operating noise up and away from the living area. The rigid top panel effectively isolates any motor sound. Isolator mounted compressor and the rippled fins of the condenser coil, muffle the normal fan motor and compressor operating sounds. The unique formed base pan also aids in sound alterations with it's “Super-Structure” design. This design strategically places embossments in the pan for optimum strength and rigidity.

FAN SYSTEM

All models operate over a wide range of design condi- tions with an (E.C.M.) electronically commutated motor that automatically adjusts the blower speed to meet a wide range of static requirements. These units easily match all types of applications and provides greater on site flexibility to match comfort requirements.

SIMPLE CONTROL CIRCUIT

A low voltage printed circuit board contains a low volt- age terminal strip. The electrical control box is not located in the compressor compartment. All wiring internal to the unit is color/number coded.

CONTROLS

Reliable demand defrost control provides defrost. Defrost control also provides an “X” terminal to provide a 24 volt signal for room thermostat “LED” indication of unit lockout, plus, built in 5 minute anti-short cycle pro- tection.

2

Unitary Products Group

Image 2 Contents
On Site Flexibility Lower Installation CostOperating Efficiency Utility Connections Made EasyDurable Finish Condensate PANCondensate Drain Full Perimeter Base RailsEasy Service Access LOW MaintenanceSecured Service Access Ports Replacement PartsRoof Curbs Table of ContentsRectangle to Round Adapters Manual Outdoor DamperHSPF1 RATING2 MBH COP Single Phase Three PhasePhysical Data Nominal Capacity KW BHP MBH Seer EEROutdoor Coil WB F Temperature of AIR on Indoor Coil Temperature AIR onCooling Capacities 2 TON BHP024 Cooling Capacities 2-1/2 TON BHP030 Cooling Capacities 3 TON BHP036 Cooling Capacities 3-1/2 TON BHP042 Cooling Capacities 4 TON BHP048 Heating Capacities 2-1/2 TON BHP030 CFM Return CAP1 Outdoor AIR TEMPERATURE, F 72% RH AIR FHeating Capacities 2 TON BHP024 Heating Capacities 3 TON BHP036 Heating Capacities 3-1/2 TON BHP042Heating Capacities 4 TON BHP048 Additional Static Resistance RESISTANCE, IWG Description CFMField Wiring Diagram Electrical Data Basic Unit Electrical Data 13 Seer Heat Pump / Electric Heat RLA LRAModel BHP B1HP Shipping Operating Corner Weights Unit SizeApplication Data Unit Dimensions Typical Applications Roof Curb Dimensions Typical Wiring Diagram 208/230-1-60 Power Supply Typical Wiring Diagram 230-3-60 Power Supply Typical Wiring Diagram 460-3-60 Power Supply General Description Indoor Supply FAN AssemblyOutdoor FAN Assembly Unit CabinetElectrical Requirements Unit Operating CharacteristicsElectric Heating Section 036-21528-003-A-0703 Unitary 5005 Norman Products York Group Drive 73069
Related manuals