Example: Scanning
Using "Trig Out"
and " Event In"
Ports
This example uses the HP E1300A/E1301A mainframe "Trig Out" and "Event In" ports to synchronize RF multiplexer channel closures with an external measurement device. See the figure below for typical user connections. For this example, the mainframe and instrument are connected via
With this example, since synchronization with the computer cannot be ensured, the external instrument must have internal memory capacity to store the readings. Also, you must add the appropriate instrument commands to line 10. The sequence of operation is:
1.INIT (line 50) closes channel 100.
2.The channel closure causes a trigger output from the "Trig Out" port.
3.Trigger to Ext Trig In starts channel 100 measurement.
4.Channel 100 measurement result is stored in instrument.
5.Trigger is then output from multimeter’s "MEASUREMENT COMPLETE" port.
6.Trigger to "Event In" port advances scan to channel 101.
7.Steps
10 | OUTPUT 722;"TRIG EXT;..." | ! Configure instrument |
20 | OUTPUT 70915;"OUTP ON" | ! Enables "Trig Out" port |
30 | OUTPUT 70915;"TRIG:SOUR EXT" | ! Event In triggering |
40 | OUTPUT 70915;"SCAN (@100:102)" | ! Scan channels |
50 | OUTPUT 70915;"INIT" | ! Enable scan |
60 | END |
|
Figure 4-4. Scan Using "Trig Out" and "Event In" Ports
Chapter 4 | Understanding the HP E1366A/E1367A RF Multiplexers 35 |