York BCH 036 General, Safety Considerations, Inspection, Reference, Renewal Parts, Approvals

Page 4
GENERAL

177820-YIM-A-0506

GENERAL

YORK Model BCH units are single package heat pumps. These are designed for outdoor installation on a rooftop or slab.

The units are completely assembled on rigid, perma- nently attached base rails. All piping, refrigerant charge, and electrical wiring is factory installed and tested. The units require electric power, duct connec- tions, installation of fixed outdoor air intake damper (units without economizer or motorized damper option only) at the point of installation.

The supplemental field installed electric heaters have nickel-chrome elements and utilize single point power connection.

SAFETY CONSIDERATIONS

Due to system pressure, moving parts and electrical components, installation and servicing of air condition- ing equipment can be hazardous. Only qualified, trained, service personnel should install, repair, main- tain or service this equipment.

Observe all precautions in the literature, on labels and tags accompanying the equipment whenever working on air conditioning equipment. Be sure to follow all other safety precautions that apply.

Wear safety glasses and work gloves, and follow all safety codes. Use a quenching cloth and have a fire extinguisher available for all brazing operations.

INSPECTION

As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the car- rier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. Refer to Form 50.15-NM for additional information.

REFERENCE

Additional information on the design, installation, oper- ation and service of this equipment is available in the following reference forms:

177820 -General Installation

255036 - Technical Guide

RENEWAL PARTS

Contact your local York® parts distribution center for authorized replacement parts.

APPROVALS

Design listed by CSA as follows:

For use as a heat pump only with or without optional electric heat.

For outdoor installation only.

For installation on combustible material.

This product must be installed in strict compli- ance with the enclosed installation instructions and any applicable local, state, and national codes including, but not limited to, building, electrical, and mechanical codes.

Improper installation may create a condition where the operation of the product could cause personal injury or property damage.

The installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the installation easier. Cau- tions are given to prevent equipment damage. Warn- ings are given to alert installer that personal injury and/ or equipment damage may result if installation proce- dure is not handled properly.

4

Unitary Products Group

Image 4
Contents BCH INSTALLATION MANUALCONTENTS SUNLINE SINGLE PACKAGE HEAT PUMPSEQUENCE OF OPERATIONS OVERVIEW TABLE OF CONTENTSCOOLING SEQUENCE OF OPERATION LIST OF FIGURES LIST OF TABLESSAFETY CONSIDERATIONS GENERALINSPECTION REFERENCEINSTALLATION INSTALLATION SAFETY INFORMATIONPRODUCT NOMENCLATURE LIMITATIONSTABLE 1 UNIT APPLICATION DATA BCH LOCATIONRIGGING AND HANDLING CLEARANCESDUCTWORK CONDENSATE DRAINFIGURE 1 - RECOMMENDED DRAIN PIPING COMPRESSORS FIGURE 2 - COMPRESSOR RESTRAINING BRACKETSERVICE ACCESS FILTERSTYPICAL POWER WIRING TYPICAL CONTROL WIRINGFIGURE 3 - TYPICAL FIELD POWER & CONTROL WIRING COOLING / HEATING 24 VOLT THERMOSTATPOWER AND CONTROL WIRING TABLE 2 CONTROL WIRE SIZESOPTIONS/ACCESSORIES THERMOSTATTABLE 3 ELECTRIC HEATER CFM LIMITATIONS ECONOMIZER/MOTORIZED DAMPER AND RAIN HOODFIGURE 4 - ENTHALPY SETPOINT ADJUSTMENT FIGURE 5 - HONEYWELL ECONOMIZER CONTROL W7212MINIMUM POSITION ADJUSTMENT ENTHALPY SET POINT ADJUSTMENTTABLE 5 BCH 4 POINT LOADS WEIGHT DISTRIBUTION TABLE 6 BCH 6 POINT LOADS WEIGHT DISTRIBUTIONFIGURE 6 - FOUR AND SIX POINT LOADING TABLE 4 CENTER OF GRAVITY ALL MODELSTABLE 8 OPERATING WEIGHTS LBS TABLE 7 PHYSICAL DATACOMPRESSORS Unitary Products Group None Unitary Products Group TABLE 11 ELECTRIC HEAT CORRECTION FACTORS TABLE 12 VOLTAGE LIMITATIONS1POWER SUPPLY NOMINAL VOLTAGEDETAIL “A” FIGURE 8 - UNIT WITH ECONOMIZER RAINHOODDETAIL “B” FIGURE 10 - UNIT DIMENSIONS REAR VIEW FIGURE 11 - DISCONNECT/BLOWER ACCESS LOCATIONTABLE 13 UTILITIES ENTRY TABLE 14 MINIMUM CLEARANCESUnitary Products Group Page Unitary Products Group 177820-YIM-A-0506 TABLE 19 BELT DRIVE BLOWER MOTOR AND DRIVE DATAUnitary Products Group FIGURE 12 - BELT ADJUSTMENT TABLE 20 STATIC RESISTANCESPHASING 5.Afteradjusting,re-tightennutsAOPERATION FIGURE 13 - PRESSURE DROP ACROSS COILSEQUENCE OF OPERATIONS OVERVIEW COOLING SEQUENCE OF OPERATIONCOOLING OPERATION ERRORS ECONOMIZER SINGLE OR DUAL WITH POWER EXHAUSTHIGH-PRESSURELIMIT SWITCH INTERMITTENT BLOWERSAFETY CONTROLS COMPRESSOR PROTECTIONLOW-PRESSURELIMIT SWITCH FREEZESTATSAFETY CONTROLS TABLE 21 ELECTRIC HEAT LIMIT CONTROL SETTING START-UPCOOLINGHEAT ANTICIPATOR SETPOINTS TABLE 22 ELECTRIC HEAT ANTICIPATOR SETPOINTSTROUBLESHOOTING COOLING TROUBLESHOOTING GUIDEOPERATING INSTRUCTIONS POST START CHECK LISTa.24 volts at the thermostat Y1 terminal 177820-YIM-A-0506Unitary Products Group MAINTENANCE NORMAL MAINTENANCEUNIT FLASH CODES TABLE 23 UNIT CONTROL BOARD FLASH CODESMOTORS OUTDOOR COIL177820-YIM-A-0506 Unitary Products GroupUnitary 5005Norman Products