York 048 & 060 Typical Power Wiring, Typical Control Wiring, Typical Field Power & Control Wiring

Page 9
TYPICAL POWER WIRING

177820-YIM-A-0506

TYPICAL POWER WIRING

REFER TO THE ELECTRICAL DATA

TABLES TO SIZE THE DISCONNECT

SWITCH, OVERCURRENT PROTEC-

TION AND WIRING.

TYPICAL CONTROL WIRING

COOLING / HEATING (24 VOLT THERMOSTAT)

THERMOSTAT1

TERMINALS

 

 

UNIT TERMINAL

 

 

RH

STRIP TB1

 

ADD

 

 

 

 

 

JUMPER

RC

R

 

 

Y

Y1

24 VOLT

 

 

 

 

 

 

TRANSFORMER

 

 

Y2

 

WW1

W2

GG

C

124 VOLT THERMOSTAT 2ET07701024. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO HAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE THERMOSTAT 2TH0471024.

COOLING / HEATING (ELECTRONIC THERMOSTAT)

MULTI STAGE

 

THERMOSTAT1

 

 

COOLING / HEATING (ELECTRONIC THERMOSTAT)

 

TERMINALS

 

UNIT TERMINAL

ADD

 

RC

 

 

STRIP TB1

24 VOLT

 

SINGLE STAGE

 

RH

 

 

R

TRANSFORMER

 

 

JUMPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y1

 

 

Y1

 

THERMOSTAT1

 

 

 

Y2

 

2

Y2

 

TERMINALS

UNIT TERMINAL

 

 

 

 

 

 

 

 

 

W1

 

 

W1

 

 

STRIP TB1

 

4

W2

 

3

W2

 

RH

 

 

 

 

 

 

 

 

 

 

 

 

G

 

 

G

 

RC

R

 

 

B

 

 

C

ADD

Y

Y1

 

 

 

 

JUMPER

 

 

LED 1

 

 

X

W

W1

 

 

 

 

 

 

 

LED 2

NOT

 

OCC

 

G

G

 

 

 

USED

 

 

 

 

 

COM

4

 

 

 

C

 

 

A1

 

 

 

 

 

ADD

 

 

 

 

 

 

24 VOLT

JUMPER

 

A2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

TO REMOTE SENSOR

 

 

TRANSFORMER

TTYPICAL CONTROL WIRING 2TH040702224 IF USED

 

 

1ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET07701024 (INCLUDES SUBBASE).

1

ELECTRONIC PROGRAMMABLE THERMOSTAT 2ET04700224 (INCLUDES SUBBASE).

TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE THERMOSTAT

2

SECOND STAGE COOLING IS NOT REQUIRED ON UNITS LESS ECONOMIZER.

2TH04700224.

3SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER.

4REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PLUG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS A1 AND A2 PROVIDE A RELAY OUT-PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SET-BACK POSITION.

FIGURE 3 - TYPICAL FIELD POWER & CONTROL WIRING

Unitary Products Group

9

Image 9
Contents INSTALLATION MANUAL BCHCONTENTS SUNLINE SINGLE PACKAGE HEAT PUMPTABLE OF CONTENTS SEQUENCE OF OPERATIONS OVERVIEWCOOLING SEQUENCE OF OPERATION LIST OF TABLES LIST OF FIGURESGENERAL SAFETY CONSIDERATIONSINSPECTION REFERENCEINSTALLATION SAFETY INFORMATION INSTALLATIONPRODUCT NOMENCLATURE LIMITATIONSLOCATION TABLE 1 UNIT APPLICATION DATA BCHRIGGING AND HANDLING CLEARANCESCONDENSATE DRAIN DUCTWORKFIGURE 1 - RECOMMENDED DRAIN PIPING COMPRESSORS FIGURE 2 - COMPRESSOR RESTRAINING BRACKETFILTERS SERVICE ACCESSTYPICAL CONTROL WIRING TYPICAL POWER WIRINGFIGURE 3 - TYPICAL FIELD POWER & CONTROL WIRING COOLING / HEATING 24 VOLT THERMOSTATTABLE 2 CONTROL WIRE SIZES POWER AND CONTROL WIRINGOPTIONS/ACCESSORIES THERMOSTATECONOMIZER/MOTORIZED DAMPER AND RAIN HOOD TABLE 3 ELECTRIC HEATER CFM LIMITATIONSFIGURE 5 - HONEYWELL ECONOMIZER CONTROL W7212 FIGURE 4 - ENTHALPY SETPOINT ADJUSTMENTMINIMUM POSITION ADJUSTMENT ENTHALPY SET POINT ADJUSTMENTTABLE 6 BCH 6 POINT LOADS WEIGHT DISTRIBUTION TABLE 5 BCH 4 POINT LOADS WEIGHT DISTRIBUTIONFIGURE 6 - FOUR AND SIX POINT LOADING TABLE 4 CENTER OF GRAVITY ALL MODELSTABLE 7 PHYSICAL DATA TABLE 8 OPERATING WEIGHTS LBSCOMPRESSORS Unitary Products Group None Unitary Products Group TABLE 12 VOLTAGE LIMITATIONS1 TABLE 11 ELECTRIC HEAT CORRECTION FACTORSPOWER SUPPLY NOMINAL VOLTAGEFIGURE 8 - UNIT WITH ECONOMIZER RAINHOOD DETAIL “A”DETAIL “B” FIGURE 11 - DISCONNECT/BLOWER ACCESS LOCATION FIGURE 10 - UNIT DIMENSIONS REAR VIEWTABLE 13 UTILITIES ENTRY TABLE 14 MINIMUM CLEARANCESUnitary Products Group Page Unitary Products Group TABLE 19 BELT DRIVE BLOWER MOTOR AND DRIVE DATA 177820-YIM-A-0506Unitary Products Group TABLE 20 STATIC RESISTANCES FIGURE 12 - BELT ADJUSTMENTPHASING 5.Afteradjusting,re-tightennutsAFIGURE 13 - PRESSURE DROP ACROSS COIL OPERATIONSEQUENCE OF OPERATIONS OVERVIEW COOLING SEQUENCE OF OPERATIONECONOMIZER SINGLE OR DUAL WITH POWER EXHAUST COOLING OPERATION ERRORSHIGH-PRESSURELIMIT SWITCH INTERMITTENT BLOWERCOMPRESSOR PROTECTION SAFETY CONTROLSLOW-PRESSURELIMIT SWITCH FREEZESTATSAFETY CONTROLS START-UPCOOLING TABLE 21 ELECTRIC HEAT LIMIT CONTROL SETTINGHEAT ANTICIPATOR SETPOINTS TABLE 22 ELECTRIC HEAT ANTICIPATOR SETPOINTSCOOLING TROUBLESHOOTING GUIDE TROUBLESHOOTINGOPERATING INSTRUCTIONS POST START CHECK LIST177820-YIM-A-0506 a.24 volts at the thermostat Y1 terminalUnitary Products Group NORMAL MAINTENANCE MAINTENANCEUNIT FLASH CODES TABLE 23 UNIT CONTROL BOARD FLASH CODESOUTDOOR COIL MOTORS177820-YIM-A-0506 Unitary Products Group5005 UnitaryNorman Products