NOTE If the file name or path includes a space, enclose the file name or path in quotation marks. For example, type put “C:\MY DOCUMENTS\LJ\P3005FW.RFU”
The following series of messages appears in the command window:
200 PORT command successful
150 Opening BINARY mode data connection
226 Ready
226 Processing Job
226 Transfer complete
Then, a message that contains the
10.The download process begins and the firmware is updated on the device. This can take approximately five minutes. Let the process finish without further interaction with the device or computer.
NOTE The device automatically turns off and then on again after processing the upgrade.
11.At the command prompt, type: bye to exit the FTP command.
12.At the command prompt, type: exit to return to the Windows interface.
NOTE The device can receive an .RFU file update as long as it is in a "ready" state.
The elapsed time for an update depends on the I/O transfer time, as well as the time that it takes for the device to reinitialize. The I/O transfer time depends on a number of things, including the speed of the host computer that is sending the update. If the remote firmware update process is interrupted before the firmware is downloaded (while Receiving Upgrade appears on the
Use HP Web Jetadmin to upgrade the firmware
This procedure requires that you install HP Web Jetadmin Version 7.0 or later on the computer.
1.Start HP Web Jetadmin.
2.Open the Device Management folder in the
3.Expand the Device Lists folder and select All Devices. Locate the device in the list, and then click to select it.
If you need to upgrade the firmware for multiple devices, select all of them by pressing the Ctrl key as you click the name of each device.
4.Locate the
ENWW | Upgrade the firmware 169 |