APPENDIX “A” ENGINEERING DATA

Pump Size

A

8x6x14F-S

H8x6x14F-S

8x6x14F-L

H8x6x14F-L

8x6x18

H8x6x18

 

 

8200

8200

8200

8200

8200

8200

 

 

 

 

 

 

 

 

Number of Stages

 

2

2

2

2

2

2

Approval Flow Rate (GPM)

 

500/750

500/750

500/750

500/750

500/750

500/750

 

 

/1000

/1000

/1000

/1000

/1000

/1000

 

 

 

 

 

 

 

 

CASING DATA

(All Dimensions in Inches)

Flange Rating ASA

Suction

125 or 250

125 or 250

125 or 250

125 or 250

125

250

Standard

Discharge

250

800

250

800

250

250

Casing Material

 

Cast Iron

Ductile Iron

Cast Iron

Ductile Iron

Cast Iron

Ductile Iron

 

 

ASTM A48

ASTM A536

ASTM A48

ASTM A536

ASTM A48

ASTM A536

 

 

Class 35

Gr. 65-45-12

Class 35

Gr. 65-45-12

Class 35

Gr. 65-45-12

Max. Working Pressure (PSIG)

 

500

800

500

800

375

500

Max. Suction Pressure (PSIG)

 

100

300

100

300

100

200

Max. Hydrostatic Pressure (PSIG)

750

1200

750

1200

563

750

Standard Hydrostatic Test

 

625

1000

625

1000

468

625

Pressure (PSIG)

 

 

 

 

 

 

 

Casing Wall Thickness

 

.75

.75

.75

.75

.75

.75

STUFFING BOX DATA

(All Dimensions in Inches)

Bore

3.75

3.75

3.75

3.75

3.75

3.75

Depth

4.06

4.06

4.06

4.06

4.06

4.06

Packing: No. Rings/Size Square

5/.50

5/.50

5/.50

5/.50

5/.50

5/.50

Seal Cage Width

.94

.94

.94

.94

.94

.94

Shaft Sleeve O.D.

2.75

2.75

2.75

2.75

2.75

2.75

IMPELLER DESIGN DATA

(All Dimensions in Inches)

No. of Vanes

6

6

6

6

6

6

Inlet Area (Sq. Inches)

26.75

26.75

33.14

33.14

28.72

28.72

Maximum Diameter

14.0

14.0

14.0

14.0

18.0

18.0

Minimum Diameter

9.0

9.0

9.0

9.0

13.5

13.5

Maximum Sphere

.50

.50

.63

.63

.63

.63

WR for Max. Dia. (Lbs-Ft)

8.5

8.5

8.0

8.0

20.0

20.0

Wear Ring Clearance - Diametral

.015-.017

.015-.017

015-.017

015-.017

015-.017

015-.017

SHAFT AND BEARING DATA

(All Dimensions in Inches)

Diameter Thru Impeller

 

2.437

2.437

2.437

2.437

2.437

2.437

Diameter Thru Sleeve

 

2.375

2.375

2.375

2.375

2.375

2.375

Diameter at Coupling

 

2.125

2.125

2.125

2.125

2.125

2.125

Shaft Span – Brg. to Brg.

 

33.45

33.45

33.45

33.45

33.45

33.45

Ball Bearings

Inboard Brg. No.

5311

5311

5311

5311

5311

5311

 

Dia. Thru Brg.

2.1654

2.1654

2.1654

2.1654

2.1654

2.1654

 

Outboard Brg. No.

7311 BG (2)

7311 BG (2)

7311 BG (2)

7311 BG (2)

7311 BG (2)

7311 BG (2)

 

Dia. Thru Brg.

2.1654

2.1654

2.1654

2.1654

2.1654

2.1654

Frame Number

 

F27-A1

F27-A1

F27-A1

F27-A1

F27-A1

F27-A1

Instruction Book Number

 

AC2675

AC2675

AC2675

AC2675

AC2675

AC2675

A (H) Prefix indicates High Pressure Casing

 

 

 

 

 

 

30

Image 30
Contents Series Base Mounted Centrifugal Fire Pumps Table of Contents Maximum Working Pressure DescriptionOperational Limits Seal Operating LimitsSafety Instructions Safety InstructionsThermal Safety Additional Safety RequirementsElectrical Safety Mechanical SafetyInstallation Pump LocationReceiving Pump Temporary Storage LocationFoundation See ANSI/OSHA Coupler Guard REMOVAL/INSTALLATION Base Plate Setting Before PipingGrouting Procedure Alignment ProcedureANSI/OSHA Coupler Guard REMOVAL/INSTALLATION InstallationRemoval Incorrect Alignment Correct AlignmentDoweling Parallelindicator AlignmentAngulardial Suction and Discharge PipingSuction Installations Piping Supports not Shown Suction PipingValves in Suction Piping Discharge PipingValves in Discharge Piping Pressure Gauges Pump InsulationStuffing BOX Lubrication Controlled Pressure System Priming OperationPRE-START Checks StartingGeneral Maintenance MaintenanceField Testing Maintenance of Pump DUE to Flood DamageCleaning Without Dismantling Pump Bearing Lubrication GreasePacking Seal Maintenance Time Table Every Month Months Every YearCures Trouble ShootingCauses No Liquid DeliveredNot Enough Pressure Pump Takes Too Much Power Causes CuresPump Operates For Short Time, Then Stops Changing Rotation Clockwise Rotation Viewed from the Coupling ENDCounterclockwise Rotation Viewed from the Coupling END Service Instructions Disassembly and Reassembly ProceduresDismantling Pump with Packing Page Dimension a = Assembly Pump with Packing 350 FT.LBS MIN. Torque Required Page Stuffing BOX Data Appendix a Engineering DataCasing Data Impeller Design DataAppendix B Exploded View 8200 Series Fire Pump Clockwise RotationReplacement Parts List Part Number Part Name QuantityInstructions for Ordering Parts Appendix C Field Test Report Single Phase Motor Three Phase Motor Useful FormulasFire Pump Canada

8200 Series specifications

The AC International 8200 Series represents a cutting-edge advancement in the realm of commercial and industrial automation. Tailored for efficiency and flexibility, this series is designed to meet the rigorous demands of modern applications across various sectors such as manufacturing, logistics, and energy management.

One of the standout features of the AC International 8200 Series is its robust control system. Equipped with an advanced microprocessor, the system ensures high performance, enabling real-time data processing and decision-making. This feature enhances the capability of users to manage complex operations while maintaining optimal productivity levels.

The 8200 Series integrates seamlessly with the latest communication protocols, such as Ethernet/IP and Modbus, allowing for smooth integration into existing infrastructures. This interoperability ensures that organizations can adopt the new series without incurring significant costs associated with overhauling their current systems.

Energy efficiency is another key characteristic of the 8200 Series. It incorporates a variety of smart technologies, including power monitoring and energy-saving modes, which help organizations reduce their operational costs and environmental footprint. These features are especially beneficial in industries where energy consumption is a significant concern.

In terms of user interface, the AC International 8200 Series offers a customizable touchscreen display that provides operators with real-time insights into their systems. This user-friendly interface facilitates quick troubleshooting and comprehensive monitoring, thereby promoting operational efficiency.

Furthermore, the series boasts enhanced safety features, including emergency stop functions and overload protection mechanisms. These safety characteristics are critical in environments where machinery operates at high capacities, ensuring the well-being of personnel and minimizing risks associated with operational failure.

With its modular design, the 8200 Series allows for easy scalability. This means that businesses can expand their systems according to growth and evolving demands without compromising performance or requiring extensive modifications.

Finally, AC International backs the 8200 Series with unparalleled customer support and comprehensive training resources, ensuring that businesses can fully harness the potential of their investments. As industries continue to evolve and embrace digital transformation, the AC International 8200 Series stands out as an essential solution for those looking to improve efficiency, safety, and sustainability in their operations.