ASSEMBLY (PUMP WITH PACKING)

All bearings, O-rings, seals, gaskets, impeller rings, and casing wear rings should be replaced with new parts during assembly. All reusable parts should be cleaned of all foreign matter before reassembling. The main casing joint gasket can be made using the upper or lower half as a template. Lay the gasket material on the casing joint and mark it by pressing it against the edges of the casing. Trim the gasket so that it is flush with the inside edges of the casing.

NOTE: Precut casing gaskets (2-153-5, -6) can be ordered to minimize the amount of trimming.

1.Place impeller key (3-911-1) in shaft (3- 007-0).

2.Identify the first and second stage impellers (4-002-0) by the cast label. For clockwise rotation, locate the second stage impeller on the shaft per Figure 11 dimension ‘A’. For counter-clockwise rotation, locate the first stage impeller per Figure 12 dimension ‘A’.

3.Pre-assemble interstage bushing (3-034-

0)and diaphragm (3-231-0) assembly as follows:

a)Install O-rings (3-914-7, -8) in the three grooves on the interstage bushing.

b)Lightly press the bushing into the diaphragm, locating the hole in the bushing over the pin in the diaphragm. Install snap ring (3-915-0) to secure assembly.

4.Slide interstage busing assembly over shaft and place over the rear hub of the impeller.

5.Place the other impeller on the shaft and slide under the interstage bushing until it touches the impeller already installed.

Verify dimension ‘A’ is maintained. See Figure 11 or 12.

6.Apply RTV (Dow Corning Silicone Sealant or equivalent) uniformly about shaft sleeve (3-009-9) inside diameter, covering an area of about 1/2 inch at each impeller end of sleeve. Also, apply sealant to the face of the impellers.

7.Slide shaft sleeves onto shaft, rotating the sleeves to evenly distribute the sealant applied in above step. Rotate until pin in

sleeve engages into keyway of impellers and push sleeves against impeller face until the sleeve is flush against the face. Wipe off any excess sealant.

8.Place the sleeve O-ring (3-914-9) onto shaft and place in sleeve counterbore. Verify that dimension ‘A’ is maintained, then using a pin spanner wrench and hammer, securely tighten the shaft sleeve nuts (3-015-9). Drill a shallow recess in the shaft through the set screw hole in each of the shaft sleeve nuts. Stake each shaft sleeve nut in position with cup point set screws (3-902-9).

9.Slide casing rings (3-003-9) onto the impellers.

10.Place two O-rings (6-914-9) on each stuffbox bushing (6-008-0), then slide over shaft sleeve with the beveled end facing the impeller.

11.Start heating bearings (3-026-3, -4) so they will be ready to use in a later step. Use dry heat from induction heat lamps or electric furnace, or a 10 - 15% soluble oil and water solution.

CAUTION:

DO NOT EXCEED 275°F. Failure to follow these instructions could result in injury or property damage.

CAUTION:

These are precision, high quality bearings. Exercise care at all times to keep them clean and free from foreign matter. Failure to follow these instructions could result in injury or property damage.

12.Assemble lip seal (3-177-9) in each bearing cap (5-018-0). Seal lip or pressure side of seal must point away from the end of the shaft the lip seal is assembled on.

13.Slide deflectors (3-136-9) and bearing caps on the shaft. Install snap ring (5-915- 3) on the inboard side of shaft. Install the split ring (5-050-4) and retaining collar (5- 421-4) on the outboard side of shaft.

14.Using gloves, install the double row ball bearing on the inboard side and locate against snap ring.

15.Using gloves, install the two angular contact bearings on the outboard end of shaft. These bearings must be installed “back to back” (wide shoulders of outer

27

Image 27
Contents Series Base Mounted Centrifugal Fire Pumps Table of Contents Seal Operating Limits DescriptionOperational Limits Maximum Working PressureSafety Instructions Safety InstructionsMechanical Safety Additional Safety RequirementsElectrical Safety Thermal SafetyInstallation Pump LocationReceiving Pump Temporary Storage LocationFoundation Alignment Procedure Base Plate Setting Before PipingGrouting Procedure See ANSI/OSHA Coupler Guard REMOVAL/INSTALLATIONANSI/OSHA Coupler Guard REMOVAL/INSTALLATION InstallationRemoval Correct Alignment Incorrect AlignmentSuction and Discharge Piping Parallelindicator AlignmentAngulardial DowelingSuction Piping Suction Installations Piping Supports not ShownValves in Suction Piping Discharge PipingValves in Discharge Piping Pressure Gauges Pump InsulationStuffing BOX Lubrication Controlled Pressure System Starting OperationPRE-START Checks PrimingMaintenance of Pump DUE to Flood Damage MaintenanceField Testing General MaintenanceCleaning Without Dismantling Pump Bearing Lubrication GreasePacking Seal Every Month Months Every Year Maintenance Time TableNo Liquid Delivered Trouble ShootingCauses CuresNot Enough Pressure Pump Takes Too Much Power Causes CuresPump Operates For Short Time, Then Stops Changing Rotation Clockwise Rotation Viewed from the Coupling ENDCounterclockwise Rotation Viewed from the Coupling END Service Instructions Disassembly and Reassembly ProceduresDismantling Pump with Packing Page Dimension a = Assembly Pump with Packing 350 FT.LBS MIN. Torque Required Page Impeller Design Data Appendix a Engineering DataCasing Data Stuffing BOX DataExploded View 8200 Series Fire Pump Clockwise Rotation Appendix BPart Number Part Name Quantity Replacement Parts ListInstructions for Ordering Parts Appendix C Field Test Report Useful Formulas Single Phase Motor Three Phase MotorFire Pump Canada

8200 Series specifications

The AC International 8200 Series represents a cutting-edge advancement in the realm of commercial and industrial automation. Tailored for efficiency and flexibility, this series is designed to meet the rigorous demands of modern applications across various sectors such as manufacturing, logistics, and energy management.

One of the standout features of the AC International 8200 Series is its robust control system. Equipped with an advanced microprocessor, the system ensures high performance, enabling real-time data processing and decision-making. This feature enhances the capability of users to manage complex operations while maintaining optimal productivity levels.

The 8200 Series integrates seamlessly with the latest communication protocols, such as Ethernet/IP and Modbus, allowing for smooth integration into existing infrastructures. This interoperability ensures that organizations can adopt the new series without incurring significant costs associated with overhauling their current systems.

Energy efficiency is another key characteristic of the 8200 Series. It incorporates a variety of smart technologies, including power monitoring and energy-saving modes, which help organizations reduce their operational costs and environmental footprint. These features are especially beneficial in industries where energy consumption is a significant concern.

In terms of user interface, the AC International 8200 Series offers a customizable touchscreen display that provides operators with real-time insights into their systems. This user-friendly interface facilitates quick troubleshooting and comprehensive monitoring, thereby promoting operational efficiency.

Furthermore, the series boasts enhanced safety features, including emergency stop functions and overload protection mechanisms. These safety characteristics are critical in environments where machinery operates at high capacities, ensuring the well-being of personnel and minimizing risks associated with operational failure.

With its modular design, the 8200 Series allows for easy scalability. This means that businesses can expand their systems according to growth and evolving demands without compromising performance or requiring extensive modifications.

Finally, AC International backs the 8200 Series with unparalleled customer support and comprehensive training resources, ensuring that businesses can fully harness the potential of their investments. As industries continue to evolve and embrace digital transformation, the AC International 8200 Series stands out as an essential solution for those looking to improve efficiency, safety, and sustainability in their operations.