12.Remove casing rings (3-003-9) from impeller (4-002-0).

13.Remove set screw (3-902-9) from shaft nuts. Remove shaft nuts (3-015-9), O-rings (3-914-9), sleeves (3-009-9), interstage bushing (3-231-0), and impellers (4-002-0).

NOTE: Apply heat uniformly to the shaft sleeve to loosen the sealant between the shaft and sleeve.

CAUTION:

DO NOT EXCEED 275°F. Failure to follow these instructions could result in injury or property damage.

To further assist in removing the sleeves, hold the shaft vertically and drop it on a block of wood. The impeller weight should force both the impellers and sleeves from the shaft.

25

Image 25
Contents Series Base Mounted Centrifugal Fire Pumps Table of Contents Operational Limits DescriptionMaximum Working Pressure Seal Operating LimitsSafety Instructions Safety InstructionsElectrical Safety Additional Safety RequirementsThermal Safety Mechanical SafetyPump Location InstallationReceiving Pump Location Temporary StorageFoundation Grouting Procedure Base Plate Setting Before PipingSee ANSI/OSHA Coupler Guard REMOVAL/INSTALLATION Alignment ProcedureInstallation ANSI/OSHA Coupler Guard REMOVAL/INSTALLATIONRemoval Correct Alignment Incorrect AlignmentAngulardial Parallelindicator AlignmentDoweling Suction and Discharge PipingSuction Piping Suction Installations Piping Supports not ShownDischarge Piping Valves in Suction PipingValves in Discharge Piping Pump Insulation Pressure GaugesStuffing BOX Lubrication Controlled Pressure System PRE-START Checks OperationPriming StartingField Testing MaintenanceGeneral Maintenance Maintenance of Pump DUE to Flood DamageBearing Lubrication Grease Cleaning Without Dismantling PumpPacking Seal Every Month Months Every Year Maintenance Time TableCauses Trouble ShootingCures No Liquid DeliveredNot Enough Pressure Causes Cures Pump Takes Too Much PowerPump Operates For Short Time, Then Stops Clockwise Rotation Viewed from the Coupling END Changing RotationCounterclockwise Rotation Viewed from the Coupling END Disassembly and Reassembly Procedures Service InstructionsDismantling Pump with Packing Page Dimension a = Assembly Pump with Packing 350 FT.LBS MIN. Torque Required Page Casing Data Appendix a Engineering DataStuffing BOX Data Impeller Design DataExploded View 8200 Series Fire Pump Clockwise Rotation Appendix BPart Number Part Name Quantity Replacement Parts ListInstructions for Ordering Parts Appendix C Field Test Report Useful Formulas Single Phase Motor Three Phase MotorFire Pump Canada

8200 Series specifications

The AC International 8200 Series represents a cutting-edge advancement in the realm of commercial and industrial automation. Tailored for efficiency and flexibility, this series is designed to meet the rigorous demands of modern applications across various sectors such as manufacturing, logistics, and energy management.

One of the standout features of the AC International 8200 Series is its robust control system. Equipped with an advanced microprocessor, the system ensures high performance, enabling real-time data processing and decision-making. This feature enhances the capability of users to manage complex operations while maintaining optimal productivity levels.

The 8200 Series integrates seamlessly with the latest communication protocols, such as Ethernet/IP and Modbus, allowing for smooth integration into existing infrastructures. This interoperability ensures that organizations can adopt the new series without incurring significant costs associated with overhauling their current systems.

Energy efficiency is another key characteristic of the 8200 Series. It incorporates a variety of smart technologies, including power monitoring and energy-saving modes, which help organizations reduce their operational costs and environmental footprint. These features are especially beneficial in industries where energy consumption is a significant concern.

In terms of user interface, the AC International 8200 Series offers a customizable touchscreen display that provides operators with real-time insights into their systems. This user-friendly interface facilitates quick troubleshooting and comprehensive monitoring, thereby promoting operational efficiency.

Furthermore, the series boasts enhanced safety features, including emergency stop functions and overload protection mechanisms. These safety characteristics are critical in environments where machinery operates at high capacities, ensuring the well-being of personnel and minimizing risks associated with operational failure.

With its modular design, the 8200 Series allows for easy scalability. This means that businesses can expand their systems according to growth and evolving demands without compromising performance or requiring extensive modifications.

Finally, AC International backs the 8200 Series with unparalleled customer support and comprehensive training resources, ensuring that businesses can fully harness the potential of their investments. As industries continue to evolve and embrace digital transformation, the AC International 8200 Series stands out as an essential solution for those looking to improve efficiency, safety, and sustainability in their operations.