MAINTENANCE TIME TABLE

EVERY MONTH

EVERY 3

MONTHS

EVERY 6

MONTHS

EVERY YEAR

Check bearing temperature with a thermometer, not by hand. If bearings are running hot (over 180°F), it may be the result of too much lubricant. If changing the lubricant does not correct the condition, disassembly and inspect the bearings. Lip seals bearing on the shaft may also cause the housing to run hot. Lubricate lip seals to correct.

Check grease lubricated bearings for saponification. This condition is usually caused by the infiltration of water or other fluid past the bearing shaft seals and can be noticed immediately upon inspection, since it gives the grease a whitish color. Wash out the bearings with a clean industrial solvent and replace the grease with the proper type as recommended.

Check the packing and replace if necessary. Use the grade recommended. Be sure the seal cages are centered in the stuffing box at the entrance of the stuffing box piping connection.

Take vibration readings on the bearing housings. Compare the readings with the last set of readings to check for possible pump component failure (e.g. bearings)

Check shaft or shaft sleeve for scoring. Scoring accelerates packing wear.

Check alignment of pump and motor. Shim up units if necessary. If misalignment reoccurs frequently, inspect the entire piping system. Unbolt piping at suction and discharge flanges to see if it springs away, thereby indicating strain on the casing. Inspect all piping supports for soundness and effective support of load. Correct as necessary.

Remove the upper half of the casing. Inspect the pump thoroughly for wear, and order replacement parts if necessary.

Check wear ring clearances. Replace when clearances become three (3) times their normal clearance or when a significant decrease in discharge pressure for the same flow rate is observed. See Engineering Data Section for standard clearances.

Remove any deposit or scaling. Clean out stuffing box piping.

Measure total dynamic suction and discharge head as a test of pump performance and pipe condition. Record the figures and compare them with the figures of the last test. This is important, especially where the fluid being pumped tends to form a deposit on internal surfaces. Inspect foot valves and check valves, especially the check valve which safeguards against water hammer when the pump stops. A faulty foot or check valve will reflect also in poor performance of the pump while in operation.

NOTE: The above time table is based on the assumption that after start-up, the unit had been constantly monitored and such a schedule was found to be consistent with operation, as shown by stable readings. Extreme or unusual applications or conditions should be taken into consideration when establishing the maintenance intervals.

19

Image 19
Contents Series Base Mounted Centrifugal Fire Pumps Table of Contents Seal Operating Limits DescriptionOperational Limits Maximum Working PressureSafety Instructions Safety InstructionsMechanical Safety Additional Safety RequirementsElectrical Safety Thermal SafetyPump Location InstallationReceiving Pump Location Temporary StorageFoundation Alignment Procedure Base Plate Setting Before PipingGrouting Procedure See ANSI/OSHA Coupler Guard REMOVAL/INSTALLATIONInstallation ANSI/OSHA Coupler Guard REMOVAL/INSTALLATIONRemoval Correct Alignment Incorrect AlignmentSuction and Discharge Piping Parallelindicator AlignmentAngulardial DowelingSuction Piping Suction Installations Piping Supports not ShownDischarge Piping Valves in Suction PipingValves in Discharge Piping Pump Insulation Pressure GaugesStuffing BOX Lubrication Controlled Pressure System Starting OperationPRE-START Checks PrimingMaintenance of Pump DUE to Flood Damage MaintenanceField Testing General MaintenanceBearing Lubrication Grease Cleaning Without Dismantling PumpPacking Seal Every Month Months Every Year Maintenance Time TableNo Liquid Delivered Trouble ShootingCauses CuresNot Enough Pressure Causes Cures Pump Takes Too Much PowerPump Operates For Short Time, Then Stops Clockwise Rotation Viewed from the Coupling END Changing RotationCounterclockwise Rotation Viewed from the Coupling END Disassembly and Reassembly Procedures Service InstructionsDismantling Pump with Packing Page Dimension a = Assembly Pump with Packing 350 FT.LBS MIN. Torque Required Page Impeller Design Data Appendix a Engineering DataCasing Data Stuffing BOX DataExploded View 8200 Series Fire Pump Clockwise Rotation Appendix BPart Number Part Name Quantity Replacement Parts ListInstructions for Ordering Parts Appendix C Field Test Report Useful Formulas Single Phase Motor Three Phase MotorFire Pump Canada

8200 Series specifications

The AC International 8200 Series represents a cutting-edge advancement in the realm of commercial and industrial automation. Tailored for efficiency and flexibility, this series is designed to meet the rigorous demands of modern applications across various sectors such as manufacturing, logistics, and energy management.

One of the standout features of the AC International 8200 Series is its robust control system. Equipped with an advanced microprocessor, the system ensures high performance, enabling real-time data processing and decision-making. This feature enhances the capability of users to manage complex operations while maintaining optimal productivity levels.

The 8200 Series integrates seamlessly with the latest communication protocols, such as Ethernet/IP and Modbus, allowing for smooth integration into existing infrastructures. This interoperability ensures that organizations can adopt the new series without incurring significant costs associated with overhauling their current systems.

Energy efficiency is another key characteristic of the 8200 Series. It incorporates a variety of smart technologies, including power monitoring and energy-saving modes, which help organizations reduce their operational costs and environmental footprint. These features are especially beneficial in industries where energy consumption is a significant concern.

In terms of user interface, the AC International 8200 Series offers a customizable touchscreen display that provides operators with real-time insights into their systems. This user-friendly interface facilitates quick troubleshooting and comprehensive monitoring, thereby promoting operational efficiency.

Furthermore, the series boasts enhanced safety features, including emergency stop functions and overload protection mechanisms. These safety characteristics are critical in environments where machinery operates at high capacities, ensuring the well-being of personnel and minimizing risks associated with operational failure.

With its modular design, the 8200 Series allows for easy scalability. This means that businesses can expand their systems according to growth and evolving demands without compromising performance or requiring extensive modifications.

Finally, AC International backs the 8200 Series with unparalleled customer support and comprehensive training resources, ensuring that businesses can fully harness the potential of their investments. As industries continue to evolve and embrace digital transformation, the AC International 8200 Series stands out as an essential solution for those looking to improve efficiency, safety, and sustainability in their operations.