General Product Information

. . . .3

Special Instructions

. . . .3

Unpacking

. . . .3

Codes

. . . .3

Warranty

. . . .3

Safety Information

. . . .3

Product Identification

. . . .5

Installation

. . . .6

Locating Pool Heater

. . . .6

Clearances from Combustible Construction

. . . .6

Base for Combustible Floors

. . . .6

Freeze Protection

. . . .7

Combustion and Ventilation Air

. . . .7

Combustion Air Filter

. . . .7

Combustion Air Options

. . . .8

Exhaust Fans

. . . .9

Venting

. . .10

General Information

. . .10

Venting Support

. . .10

Vertical Vent Termination Clearances and Location

. . .10

Sidewall Vent Termination Clearances and Location

. . .11

Combustion Air Inlet Piping

. . .12

Length of Air Inlet Piping

. . .12

Sidewall Air Inlet

. . .12

Vertical Rooftop Air Inlet

. . .13

Combined Air Inlet Points

. . .13

Vent System Options

. . .14

Barometric Damper Location

. . .14

1. Conventional Negative Draft Venting

. . .14

2. Vertical DirectAireVenting

. . .16

3. Sidewall Venting

. . .17

4. Horizontal DirectAireVenting

. . .20

5. Direct Venting

. . .21

6. Outdoor Installation Venting

. . .25

Connecting to Gas Supply

. . .26

Gas Pressure Test

. . .26

Gas Piping

. . .27

Connecting Gas Piping to the Pool Heater

. . .27

Gas Train and Controls

. . .27

Combination Gas Valves

. . .28

Venting of Combination Gas Valves

. . .28

Checking Gas Supply Pressure

. . .28

Gas Manifold Pressure Adjustment

. . .30

Pool Heater Piping Installation

. . .31

Auxiliary Mixed Water Limit Control

. . .31

Pumped Bypass

. . .31

Outdoor Operation - Outdoor 3-Way Valve Cover . .

. . .31

Manual Operation of the 3-Way Valve Actuator . . . .

. . .32

Table of Contents

 

 

Relief Valve

. . . . . . .

.34

Water Flow Switch

. . . . . . .

.34

Pump Purge Delay Option

. . . . . . .

.36

Service Indicator Option

. . . . . . .

.36

Connecting to Electrical Supply

. . . . . . .

.36

3-Way Valve Wiring

. . . . . . .

.36

Terminal Strip Connection Options

. . . . . . .

.37

Operation

. . . . . . .

.38

Lighting Instructions

. . . . . . .

.38

To Turn Off Gas To Pool Heater

. . . . . . .

.39

Pre-Start Checklist

. . . . . . .

.39

Starting the Filter System

. . . . . . .

.39

Operating Temperature Control

. . . . . . .

.40

Programming Mode

. . . . . . .

.41

Error Messages -- Temperature Control

. . . . . . .

.41

Hot Surface Ignition System

. . . . . . .

.42

Operation and Diagnostic Lights

. . . . . . .

.43

Water Chemistry

. . . . . . .

.44

Pipe Size Requirements

. . . . . . .

.45

Circulating Pump

. . . . . . .

.46

Minimum Pump Performance

. . . . . . .

.46

Heat Exchanger

. . . . . . .

.46

High Water Temperature Limit Control

. . . . . . .

.46

Cleaning and Maintenance

. . . . . . .

.47

Heat Exchanger Cleaning

. . . . . . .

.48

Combustion and Ventilation Air

. . . . . . .

.48

Adjusting Differential Air Pressure

. . . . . . .

.49

Set-Up Procedure

. . . . . . .

.49

Adjustment Procedure

. . . . . . .

.50

Servicing Hot Surface Igniter and Ignition Module

.50

Ignition System Checkout

. . . . . . .

.50

Energy Saving Recommendations

. . . . . . .

.51

Sequence of Operation

. . . . . . .

.51

Glossary

. . . . . . .

.52

Wiring Box Connections

. . . . . . .

.54

Ladder Diagram

. . . . . . .

.56

Control Box Connections

. . . . . . .

.57

Appendix A_Unit Start Up Checklist

. . . . . . .

.58

Appendix B_Adjust Menu Settings for Operating Modes .

.59

Revision Notes

Back Cover

2

Image 2
Contents GAS Heaters for Commercial Pool Applications Do not try to light any applianceCommercial Pool Heaters General Product Information Commercial Pool Heaters Product Identification Clearances from Combustible Construction Base for Combustible FloorsCFK3304 CFK3302CFK3303 Combustion Air FilterInstallation Combustion Air OptionsOutside Combustion Air, Using Ducts Exhaust FansVertical Vent Termination Clearances and Location General InformationVenting Support Sidewall Vent Termination Clearances and Location Table BSidewall Air Inlet Combustion Air Inlet PipingLength of Air Inlet Pipe Vertical Rooftop Air Inlet Combined Air Inlet PointsNegative Draft Vent System OptionsConventional Negative Draft Venting Flue Outlet Piping Common Venting SystemsInspection of a Masonry Chimney Masonry Chimney InstallationsVertical DirectAire Venting Sidewall Venting Vent KitsVenting of Flue Products Sidewall Venting Without Fan Sidewall FanSidewall Venting Termination Masonry Chimney Installation Horizontal DirectAire Venting TABLE-EDirect Venting Combustion Air Inlet Piping Horizontal DV Venting TerminationFlue Pipe Materials Air Inlet Piping Materials Connecting the Air Inlet Pipe to the Pool HeaterLength of Air Inlet Pipe Sealing Type-B Doublewall Vent Pipe or Galvanized Vent PipeCombined Combustion Air Inlet Points Vertical Rooftop Air InletHorizontal Combustion Air Inlet Clearances Outdoor Installation VentingVertical Combustion Air Inlet Clearances Outdoor Vent/Air Inlet LocationGas Pressure Test Combustion Air Fan Adjustment for startup3-Way Valve Cover Installation Outdoor Vent Cap KitGas Train and Controls Connecting Gas Piping to the Pool HeaterGas Piping Checking Gas Supply Pressure Combination Gas ValvesVenting of Combination Gas Valves TABLE-JMultiple Unit Installations Gas Supply Pipe Sizing Table KGas Manifold Pressure Adjustment To adjust to the proper manifold gas pressureAuxiliary Mixed Water Limit Control Pumped Automatic BypassWay Valve Cover Heater is Within 15 Feet of Pool Piping Heaters are within 15 feet Perpendicular of Pool Piping Automatic Chlorinator and Chemical Feeders Water Flow SwitchRelief Valve Way Automatic Bypass Valve Wiring Pump Purge Delay OptionService Indicator Option Terminal Strip Connection Options TABLE-MOperation Lighting InstructionsStarting the Filter System Pre-Start ChecklistTo Turn Off Gas To Pool Heater Operation Programming Mode Error Messages Displayed by Temperature ControllerHot Surface Ignition Control Module Diagnostic Status IndicationHot Surface Igniter and Ignition Control Module Ignition Module Lockout FunctionsIgnition and Control Timings Access to Internal Control PanelTABLE-N Water Chemistry TABLE-OPipe Size Requirements TABLE-QMinimum Pump Performance High Water Temperature Limit ControlCirculating Pump Heat ExchangerWater Circulating Pump Flue Gas Passageways Cleaning ProceduresAppliance Area Burner FlamesElectrical Burner Removal and CleaningHeat Exchanger Cleaning Combustion and Ventilation AirCombustion Air Fan Adjustment Adjusting Differential Air PressureFan Cleaning Set-Up ProcedureIgnition System Checkout Adjustment ProcedureServicing Hot Surface Igniter and Ignition Module Sequence of Operation Glossary Igniter WARM-UP and Proving Wiring BOX Connections Main Unit Connections Ladder Diagram Control BOX Connections Commercial Pool Heaters Appendix a Appendix B

F0600187510 specifications

The Lochinvar F0600187510 stands out as a premium combination boiler that caters to the heating and hot water needs of residential properties. Known for its energy efficiency and advanced technology, this model is ideal for homeowners seeking both comfort and cost savings.

One of the primary features of the Lochinvar F0600187510 is its exceptional energy efficiency. With an impressive AFUE (Annual Fuel Utilization Efficiency) rating, this boiler redefines performance standards, effectively converting a high percentage of the energy it consumes into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making it an environmentally responsible choice.

The F0600187510 is equipped with Lochinvar's advanced control system, which allows for precise temperature regulation. This system includes a user-friendly digital display, enabling homeowners to easily adjust settings for their specific heating and hot water requirements. The boiler also offers weather compensation features that optimize performance based on outdoor temperatures, ensuring maximum efficiency throughout the year.

In terms of hot water production, this model features a built-in indirect water heater design, which provides an abundant supply of domestic hot water on demand. This is ideal for households with high hot water usage, as the system can deliver multiple gallons per minute without interruption.

Moreover, the compact design of the Lochinvar F0600187510 allows for flexible installation options, making it suitable for various settings, including tight spaces. Its robust construction ensures durability and reliability, giving homeowners peace of mind regarding long-term performance.

Safety is another significant characteristic of this combination boiler. It comes with multiple built-in safety features, including flame detection, pressure sensors, and overheat protection, ensuring the system operates securely and efficiently.

Finally, the Lochinvar F0600187510 is backed by a solid warranty, providing homeowners with additional assurance of quality and support. Overall, this boiler represents a harmonious blend of innovative technology, efficiency, and reliability, making it a top choice for modern residential heating and hot water solutions.