oUnscrew the injector and replace it with the stipulated injector for the new gas supply (see table below).
Burner | Types | Pressure | Injector | Gas |
| Power | ||
| of gas | (mbar) | Marking | consumption | (kW) | |||
|
|
| (1/100 | g/h |
| l/h | Max. | Min. |
|
|
| mm) |
|
|
|
|
|
Auxiliary | Natural | 20 | 72 | - |
| 95 | 1.00 | 0.48 |
| (G20) |
|
|
|
|
|
|
|
| Butane | 30 | 50 | 73 |
| - |
|
|
| (G30) |
|
|
|
|
|
|
|
| Propane | 37 | 50 | 71 |
| - |
|
|
| (G31) |
|
|
|
|
|
|
|
Semi- | Natural | 20 | 97 | - |
| 167 | 1.75 | 0.60 |
rapid | (G20) |
|
|
|
|
|
|
|
| Butane | 30 | 65 | 127 |
| - |
|
|
| (G30) |
|
|
|
|
|
|
|
| Propane | 37 | 65 | 125 |
| - |
|
|
| (G31) |
|
|
|
|
|
|
|
Rapid | Natural | 20 | 115 | - |
| 286 | 3.00 | 1.05 |
| (G20) |
|
|
|
|
|
|
|
| Butane | 30 | 85 | 254 |
| - |
|
|
| (G30) |
|
|
|
|
|
|
|
| Propane | 37 | 85 | 250 |
| - |
|
|
| (G31) |
|
|
|
|
|
|
|
Wok | Natural | 20 | 135 | - |
| 286 | 3.50 | 1.80 |
| (G20) |
|
|
|
|
|
|
|
| Butane | 30 | 95 | 218 |
| - |
|
|
| (G30) |
|
|
|
|
|
|
|
| Propane | 37 | 95 | 214 |
| - |
|
|
| (G31) |
|
|
|
|
|
|
|
oReassemble all the burners carefully; in particular you should make sure that the flame spreader is correctly placed on the burner.
IMPORTANT: After changing the injectors YOU MUST follow the minimum flow adjustment section on the next page.
31