Lochinvar SNR200-100, SNA500-125, SNA285-125, SNR150-100, SNA400-125 service manual LOW Voltage

Page 71

TM

Installation & Service Manual

14 Diagrams (continued)

Figure 14-2Wiring Diagram

DISPLAY

LOW VOLTAGE

WARNING

120 VAC

 

DISCONNECT POWER

 

HIGH VOLTAGE

 

 

BEFORE SERVICING

 

 

 

 

 

INTEGRATED CONTROL

 

 

 

 

 

 

 

 

 

 

 

X3

 

 

 

 

 

 

 

 

 

JUNCTION

 

BOX DEPICTS

PC

 

 

 

 

 

 

 

 

 

 

 

 

 

BOX

 

 

 

 

 

 

X8

 

 

 

 

 

 

 

 

 

OPTIONAL ITEMS

INTERFACE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION BOARD

 

 

 

 

 

 

 

OR

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DHW

 

 

 

 

 

 

 

W

 

 

W

N

GND

 

 

 

 

CN1

CN2

 

 

 

X1-5

 

 

 

 

PUMP

 

 

 

 

 

 

PUMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

EXTERNAL

 

1

CN2-9

OR

X6-10

 

 

1

2

 

 

 

 

 

 

 

 

BK

 

 

 

4

 

 

 

 

 

 

 

LIMITS

 

2

CN2-3

X6-5

 

X1-3

OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X1-6

BK

 

 

BK

L

 

 

L

120V

 

 

 

 

 

 

 

 

 

 

 

W

N

GND

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PR

 

 

 

 

 

 

 

TERMINAL STRIP

 

 

 

ALARM

 

5

CN2-7

 

X3-4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTACTS

 

6

CN2-1

PR

 

X3-2

X1-8

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

RUN-TIME

 

3

CN2-8

 

X3-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

CONTACTS

 

 

 

R

 

 

X1-1

 

 

 

 

 

 

 

 

 

4

CN2-2

 

X3-3

 

R W G

 

 

 

 

 

 

 

 

 

 

 

BLOWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2 3 4

5

 

 

 

 

 

 

 

 

 

 

 

 

 

X5-5

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5-13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

CN5

 

 

 

 

X5-6

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24 VAC

CN5-1

CN2-6

X6-2

 

X5-12

 

 

 

 

 

 

 

 

 

GY

 

BL

 

 

 

BL

 

 

 

 

LOW

 

 

CN5-3

CN2-12

X6-7

 

X5-7

 

 

 

 

MANUAL RESET

 

 

BR

 

PR

 

 

 

PR

 

WATER

 

 

CN5-4

CN2-11

X6-9

 

X5-14

 

 

 

 

HI-LIMIT

 

CUT-OFF

 

 

 

 

 

 

 

 

OR/BK

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

AIR PRESSURE

 

COM

CN5-2

CN2-4

X6-3

 

 

 

 

 

 

OR

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

CN2-10

X6-8

 

 

OR/BK

 

 

 

 

SWITCH

 

 

 

 

 

 

 

X5-11

 

 

 

OR

 

BLOCKED

 

GAS

 

 

 

 

 

 

P

 

 

 

P

 

 

 

CN4-3

 

 

 

 

X5-3

 

 

 

 

DRAIN

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

 

 

 

P

 

 

X5-4

OR

 

 

 

OR

 

 

 

 

SWITCH

 

CN4-6

CN2-5

X6-4

 

 

 

 

 

AUTO RESET

 

 

 

 

GY

 

 

 

GY

 

 

 

 

 

 

 

 

 

 

X5-10

 

 

 

 

HI-LIMIT

 

 

 

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5-8

 

 

 

 

 

S2

INLET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

S1

SENSOR

 

TANK

 

S4

CN4-1

 

 

 

 

X5-1

 

 

 

 

 

OUTLET

 

 

 

 

 

 

 

 

 

 

 

 

 

SENSOR

 

 

CN4-4

CN3

 

X4

 

X5-2

W

 

 

 

 

 

S3

SENSOR

 

 

 

 

 

 

 

 

 

 

 

FLUE

 

EXTERNAL

+

 

CN4-5

 

 

 

 

Y

 

 

 

 

 

 

0-10V

 

 

 

 

X5-9

 

 

 

 

 

 

SENSOR

 

CN4-2

 

 

 

 

 

 

 

 

 

 

 

CONTROL

-

 

 

 

 

 

 

BK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X2-2

 

 

 

GAS

 

 

 

 

 

 

CN4

CN3

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

X2-1

 

 

 

VALVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W/R

FLAME

 

 

 

 

 

 

 

 

 

 

 

 

 

X1-7

ROD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TR1

 

SPARK

 

G

 

 

 

 

 

 

 

 

 

 

 

 

ROD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION HIGH VOLTAGE SPARK LEAD

Notes:

1.All wiring must be installed in accordance with: local, state, provincial and national code requirements per either N.E.C. in USA or C.S.A. in Canada.

2.If any original equipment wire as supplied with the appliance must be replaced, it must be replaced with wire having same wire gauge (AWG) and rated for a minimum of 105°C. Exceptions: Replacement high voltage spark lead and ribbon cables must be purchased from the factory. Use of a non-approved spark lead or ribbon cables can lead to operational problems which could result in non-repairable damage to the integrated controller or other components.

3.Actual connector block locations may vary from those shown on diagrams. Refer to actual components for proper connector block locations when using diagrams to troubleshoot unit.

WIRING DIAGRAM

LBL20025 REV A

71

Image 71
Contents What to do if YOU Smell GAS Installation & Service ManualContents Hazard definitions Please read before proceedingBlower Shield How it worksModels SNR150-100 -- SNA285-125 Model SNA500-125 Model SNA400-125CSA RatingsBefore locating the water heater, check Installation must comply withCloset and alcove installations Determine water heater location1Closet Installation Minimum Required Clearances Prevent combustion air contamination Flooring and foundationRemove water heater from wood pallet Do not install the Shield water heater into 3Combustion Air Direct from Outside Minimum Recommended Combustion AIR Supply to Equipment Room Direct venting options General ventingVent pipe and fittings Venting and combustion airCanada Air inlet pipe materials Air intake/vent connectionsVent and air piping Vent LengthRemoving from existing vent Vent Size If using the alternate sidewall terminationSidewall direct venting Vent/air termination sidewall2Clearance to Gravity Air Inlets Termination and fittings Prepare wall penetrationsPrepare wall penetrations Alternate Field Supplied Option 5AMultiple Vent Terminations must also comply with -1A Multiple vent/air terminationsDescription and usage Sidewall termination installationSidewall termination optional concentric vent 9Concentric Vent Dimensional Drawing Multiventing sidewall terminations 12Concentric Vent Sidewall AttachmentVent/air termination vertical Vertical direct venting2Vertical Terminations with Multiple Water Heaters Prepare roof penetrationsVertical termination optional concentric vent Vertical termination installationMultiventing vertical terminations 6Concentric Vent Roof Installation1Vertical Direct Venting w/Room Air Conventional and sidewall ventingGeneral piping information System pipingSystem water piping methods ScaldingDelta T Piping componentsWater chemistry Single Unit 3Multiple Units Water Tank Supply Gas connections Connecting gas supply pipingPropane gas Natural gasLength of Pipe in Straight Feet for 1/2 PSI Natural Gas Pipe Capacity ChartCheck inlet gas supply Gas pressure Gas valve replacementField wiring 3Low Voltage Field Wiring Connections Inputs Condensate drain Condensate disposalFinal checks before starting the water heater Start-upCheck for gas leaks Inspect/fill condensate system Check flame and combustion Start the water heaterIf water heater does not start correctly Check system and water heater2Operating Instructions Models SNR150-100 -- SNA285-125 3Operating Instructions Models SNA400-125 -- SNA500-125 General Temperature controlProtection features Operating informationSaving parameters Water heater temperature regulationAdjustable control parameters HTR Ignition Sequence of operation1Control Panel Shield control moduleStatus Display Screens Status display screensStatus Display Screens cont’d Owner maintenance Maintenance Maintenance and annual startupService technician Maintenance Check water heater relief valve Flue vent system and air pipingCheck water system Check expansion tankCheck flame signal Check ignition ground wiring Check burner flameCheck all water heater wiring Check control settingsNiosh stated First Aid Cleaning heat exchangerHandling ceramic fiber materials Oiled bearing circulatorsCheck the following TroubleshootingBefore troubleshooting Check control module fusesAbove 50% No DisplayNo Burner Operation Unit Does Not ModulateTemperature F Resistance Ω Checking temperature sensorsTroubleshooting No Flame Ign FlameSequence Fail No FlameRunning GV/RelayFan Speed Low Manual ResetHigh Limit Fan LowSensor Open SwitchFan High Fan Speed HighProgr ParametersWrite EEProm Service BlkWatch Dog Error Low 24 VACGas Supply Pressure Combustion Analysis ProcedureGas Valve Adjustment Or ObstructionModel SNA500-125 Gas valve adjustment procedureModels SNR150-100 -- SNA285-125 Model SNA400-125120 VAC DiagramsLOW Voltage

SNA400-125, SNR150-100, SNA285-125, SNR200-100, SNA500-125 specifications

Lochinvar has established itself as a leader in the realm of high-efficiency heating solutions, and its line of condensing boilers, including the SNA500-125, SNR200-100, SNA400-125, SNA285-125, and SNR150-100, exemplifies the brand’s commitment to innovation, efficiency, and reliability.

The SNA500-125 model stands out with its impressive heating capacity, designed for larger commercial applications. Featuring advanced modulating burners, it can precisely adjust its output based on real-time demand, significantly enhancing energy efficiency. The stainless steel heat exchanger ensures robust durability and improved thermal performance, while the integrated controls offer advanced diagnostic capabilities and user-friendly operation.

Next in the lineup, the SNR200-100 serves as a versatile option for mid-sized applications. Its compact design allows for flexible installation, making it a valuable choice for facilities with limited space. The boiler incorporates a high-efficiency combustion system that maximizes fuel utilization, while its low NOx emissions technology aligns with environmental standards, reducing the carbon footprint of users.

The SNA400-125 delivers a robust solution for diverse heating needs, equipped with state-of-the-art modulation technology that not only optimizes efficiency but also offers quiet operation – a crucial feature for facilities where noise reduction is paramount. This model also includes built-in redundancy options, enhancing reliability during peak operational periods.

The SNA285-125 provides a balance of performance and efficiency for smaller commercial settings. Its innovative control system offers precise temperature management and easy integration with existing systems. Energy Star certified, this model is not only cost-effective but supports sustainability efforts in various industries.

Lastly, the SNR150-100 is ideally suited for light commercial applications, featuring a compact footprint and excellent heat transfer capabilities. The user-friendly interface and robust safety features make it an excellent choice for operators prioritizing both ease of use and reliability.

All these models incorporate Lochinvar's commitment to superior design and advanced technologies, setting a benchmark in the high-efficiency heating market. With a focus on long-term performance and compliance with modern environmental standards, Lochinvar continues to deliver top-tier solutions tailored to meet diverse customer needs. Whether for large-scale operations or smaller settings, these boilers represent a significant advancement in commercial heating technology.