Lochinvar 151 Stainlesssteelairintake/ventconnections, Flue Intake Air Adapter Termination

Page 21

 

 

 

 

 

 

 

Installation & Operation Manual

3 General venting (continued)

 

 

 

 

 

Table 3B Approved Stainless Steel Terminations and Adapters

 

 

 

 

 

 

 

ProTech

 

Heat Fab

 

 

Z Flex

 

Model

 

FasNSeal

 

Saf-T Vent

 

 

Z-Vent

 

 

Flue

Intake

 

Intermediate

Flue

Intake

 

Flue

Intake Air

 

 

 

 

 

**Adapter

Air

**Adapter

Air

**Adapter

 

 

Termination

Termination

 

Adapter

Termination

Termination

 

Termination

Termination

151 - 200

300715

FSBS3

303889

KB80210

9353BUREZ-1*

9392

9314TERM

2SVSLA03

2SVSTP03

2SVSTEX0390

 

 

FSRC3(R.C)

 

 

 

5300CI

 

 

2SVSRCX03

 

286-601

F303759

FSBS4

FSAIH04

KB285600

9454BUREZ-1*

9492

9414TERM

2SVSLA04

2SVSTP04

2SVSTEX0490

 

 

FSRC4(R.C)

303888

 

 

5400CI

 

 

2SVSRCX04

 

701-801

F303759

 

FSAIH04

 

 

 

 

 

 

 

(Intake

FSBS6

 

 

 

 

 

 

 

303888

 

 

 

 

 

 

 

 

Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*= This adapter must be used in addition to the water heater adapter for Saf-T vent pipe as shown in FIG. 3-12, unless approved vent other than standard diameter is used. Consult a Heat Fab representative for questions.

**The stainless steel venting option is only available in 3" vent diameters.

Table 3C Stainless Steel Vent Termination Kit(s)

Model

Kit Number

701 - 801

KIT3137

Stainlesssteelairintake/ventconnections

1.Combustion Air Intake Connector (FIG.’s 3-12 thru 3-14) - Used to provide combustion air directly to the unit from outdoors. A fitting is provided on the unit for final connection. Combustion air piping must be supported per guidelines listed in the National Mechanical Code, Section 305, Table 305.4 or as local codes dictate.

2.Vent Connector (FIG.’s 3-12 thru 3-14) - Used to provide a passageway for conveying combustion gases to the outside. A transition fitting is provided on the unit for final connection. Vent piping must be supported per the National Building Code, Section 305, Table 305.4 or as local codes dictate.

Figure 3-12Near Water Heater Stainless Steel Venting Models 151 - 200

VENT

3" S.S. ADAPTER

3" S.S. INTERMEDIATE (FOR SAF-T VENT ONLY)

21

Image 21
Contents What to do if YOU Smell GAS Installation&OperationManual Models 151Contents Please read before proceeding When servicing the water heaterStainless steel heat exchanger Armor Water Heater How it worksModels 151 Models 601 Models 400CSA RatingsCloset and alcove installations Installation must comply withDetermine water heater location Before locating the water heater, check1Closet Installation Minimum Required Clearances Provide air openings to room Residential garage installationVent and air piping Flooring and foundationAreas likely to have contaminants Products to avoidDetermine water heater location Gas conversions Prepare water heaterRemove water heater from wood pallet Models 151Model 3Installing Propane Orifice ModelLeveling the water heater Models 601Direct venting options Sidewall Vent General ventingDirect venting options Vertical Vent, Sidewall Air Direct venting options Vertical VentRequirements for installation in Canada Install vent and combustion air pipingInstalling vent or air piping PVC/CPVC Vent piping materialsVent Pipe, and Fittings PVC/CPVC Air intake/vent connectionsStainless steel vent Air inlet pipe materialsFlue Stainlesssteelairintake/ventconnectionsFlue Intake Air Adapter Termination Model Kit NumberRemoving from existing vent Model Air Intake VentVent and air system Vent, air piping and termination Optional room airModel Kit Number Description Air contaminationSidewall direct venting If using the alternate sidewall terminationVent/air termination sidewall Determine location3AClearance to Gravity Air Inlets Seal all wall cavities Prepare wall penetrationsPrepare wall penetrations Alternate Field Supplied Option Multiple vent/air terminationsTermination and fittings Sidewall termination installation Sidewall termination optional concentric vent Models 151Description and usage 11 Concentric Multiventing sidewall terminations 13Concentric Vent Sidewall AttachmentVent/air termination vertical Vertical direct ventingMultiple vent/air terminations Prepare roof penetrationsVertical termination optional concentric vent Models 151 Vertical termination installationMinimum Combustion AIR Typical Multiventing vertical terminationsConcentric Venting Arrangement Alternate vertical concentric venting10Existing Vent as a Chase Existing vent as a chaseFlow switch adjustment Flow switch and relief valve installationSystem piping System water piping methodsScalding Piping componentsWater chemistry 4Single Heater Single Tank 2 Temperature Cold Water Supply Cold Water Supply Number of Units Model 8Double Heater Double Tank Gas connections Connecting gas supply pipingPropane gas Natural gasSingle Unit Natural Gas Pipe Capacity Chart Check inlet gas supplyLength of Pipe in Straight Feet for 1/2 PSI Gas pressure Gas valve replacementInstallation must comply with Field wiringLine voltage connections Low voltage connectionsLouver proving switch Tank thermostat Low gas pressure switchHigh gas pressure switch Flow switchAlarm contacts Wiring of the cascadeRuntime contacts 3Low Voltage Field Wiring Connections Condensate drain Condensate disposalCheck for gas leaks Inspect/fill condensate system Start-upChlorine concentration less than 200 ppm Inspect/check condensate lines and fittingsStart the water heater Final checks before starting the water heaterIf water heater does not start correctly Check system and water heaterFor Your Safety Read Before Operating 3Operating Instructions Models 400 Verify WHR circulator mode Set tank set point temperatureSet water heater operation Natural Gas PropaneSet clock Configuration of the cascadeGeneral Operating informationWater heater temperature regulation Cascade InstallerSequence of the cascade UserOperation Display Sequence of operation1Control Panel Armor water heater control moduleWater heater Information Dial Function Maintenance Maintenance and annual startup Service technicianOwner maintenance Maintenance Check all water heater wiring Check ignition ground wiringCheck control settings Check water systemCleaning heat exchanger Check flame signalPerform start-up and checks Check burner flameCheck Delta T Oiled bearing circulatorsModel Kit Part Component Number Description PC Interface Diagrams2Wiring Diagram Page Page AWII-I-O Rev C
Related manuals
Manual 16 pages 16.89 Kb

151 specifications

Lochinvar 151,286 is a notable model in the realm of commercial water heating solutions, designed primarily for large-scale applications. This model incorporates advanced technologies and features that set it apart in terms of efficiency, usability, and reliability.

One of the hallmark features of Lochinvar 151,286 is its high-efficiency system that leverages condensing technology. This technology enables the unit to extract additional heat from exhaust gases, allowing it to operate at an impressive annual fuel utilization efficiency (AFUE) rating. This not only reduces energy consumption, but it also significantly lowers operational costs.

The Lochinvar 151,286 is equipped with a robust stainless steel heat exchanger, which provides both durability and enhanced thermal efficiency. This design withstands the rigors of high-demand environments, making it ideal for restaurants, schools, hospitals, or any facility requiring consistent hot water supply. Its compact footprint allows it to be installed in tight spaces without sacrificing performance.

Another standout characteristic is its intelligent control system. The built-in touchscreen interface offers users an intuitive way to manage settings, monitor performance, and troubleshoot issues. This smart technology aids in simplifying maintenance and improves overall system reliability. The unit also features advanced safety protocols, including multiple sensors that monitor operation and provide alerts in case of irregular performance.

In terms of capacity, the Lochinvar 151,286 can deliver an impressive output, accommodating varying demands with ease. Its innovative modulation capabilities allow the unit to adjust its heating output based on real-time hot water needs, ensuring unmatched comfort and efficiency.

Supporting the model’s performance are versatile connectivity options. Lochinvar 151,286 can integrate seamlessly with building management systems, allowing facility managers to monitor and control heating processes remotely. This level of connectivity not only enhances control but also supports energy-saving strategies across the facility.

In conclusion, Lochinvar 151,286 stands out as a premium choice for commercial water heating needs. With its high-efficiency ratings, durable construction, intelligent control system, impressive capacity, and versatile connectivity, it ensures that hot water is delivered reliably and efficiently, meeting the demands of modern businesses while reducing energy costs. This combination of technology and design makes it an essential component for any large-scale facility focused on performance and sustainability.