Lochinvar 151 operation manual Concentric

Page 29

Installation & Operation Manual

4 Sidewall direct venting (continued)

Sidewall termination – optional concentric vent: Models 151 - 601

Figure 4-10Concentric Vent Dimensional Drawing -

Figure 4-11 Concentric

Vent

Dimensional

Drawing

-

Models 151 - 200

Models 286 - 501

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"A"

 

 

 

 

 

 

 

 

 

"C" DIA.

"B" DIA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3"

 

 

"D"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(76 MM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"E"

 

 

 

"G"

 

 

 

"H" DIA.

 

 

 

 

 

 

"B" DIA. PVC

 

 

 

 

 

 

 

 

 

"F"

 

 

VENT / EXHAUST

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

 

D

 

E

F

 

G

H

 

 

60"

4"

6"

21 1/8"

 

10"

7 5/8"

 

3"

6 5/8"

 

 

(1524 MM)

(102 MM)

(152 MM)

(537 MM)

(254 MM)

(194 MM)

(76 MM)

(168 MM)

NOTICE

Instead of cementing the smaller pipe to

the rain cap, a field-supplied stainless steel

 

screw may be used to secure the two (2)

 

components together when field disassembly

 

is desired for cleaning (see FIG. 4-12).

6.Install the Y concentric fitting and pipe assembly through the structure’s hole.

Do not allow insulation or other materials to NOTICE accumulate inside the pipe assembly when

installing through the hole.

￿WARNING

￿WARNING

When using the alternate screw assembly method, drill a clearance hole in the rain cap and a pilot hole in the vent pipe for the screw size being used. Failure to drill adequate holes may cause cracking of PVC components, allowing combustion products to be recirculated. Failure to follow this warning could result in personal injury or death.

Do not operate the appliance with the rain cap removed or recirculation of combustion products may occur. Water may also collect inside the larger combustion air pipe and flow to the burner enclosure. Failure to follow this warning could result in product damage or improper operation, personal injury, or death.

7.Install the rain cap and small diameter pipe assembly into the Y concentric fitting and large pipe assembly. Ensure small diameter pipe is bottomed and cemented in the Y concentric fitting for #CVK3003 installations and fastened tightly into the rubber adapter for #CVK3007 installations.

8.Secure the assembly to the structure as shown in FIG. 4-13 using field-supplied metal strapping or equivalent support material.

NOTICE

Ensure termination location clearance

dimensions are as shown in FIG. 4-7.

 

If assembly needs to be extended to allow

NOTICE

sidewall thickness requirement, the two (2)

 

 

pipes supplied in the kit may be replaced

 

by using the same diameter, field-supplied

 

SDR-26 PVC (D2241) pipe for CVK3003

 

and standard schedule 40 PVC for CVK3007.

Figure 4-12Rain Cap to Vent Pipe Alternate Assembly

 

Do not extend dimension D* more than 60

 

inches (see FIG.’s 4-10 and 4-11).

 

If assembly depth needs to be reduced,

NOTICE

dimension D can be as short as possible.

 

29

Image 29
Contents What to do if YOU Smell GAS Installation&OperationManual Models 151Contents Please read before proceeding When servicing the water heaterStainless steel heat exchanger Armor Water Heater How it worksModels 151 Models 601 Models 400CSA RatingsCloset and alcove installations Installation must comply withDetermine water heater location Before locating the water heater, check1Closet Installation Minimum Required Clearances Provide air openings to room Residential garage installationVent and air piping Flooring and foundationAreas likely to have contaminants Products to avoidDetermine water heater location Gas conversions Prepare water heaterRemove water heater from wood pallet Models 151Model 3Installing Propane Orifice ModelLeveling the water heater Models 601Direct venting options Sidewall Vent General ventingDirect venting options Vertical Vent, Sidewall Air Direct venting options Vertical VentRequirements for installation in Canada Install vent and combustion air pipingInstalling vent or air piping PVC/CPVC Vent piping materialsVent Pipe, and Fittings PVC/CPVC Air intake/vent connectionsStainless steel vent Air inlet pipe materialsFlue Stainlesssteelairintake/ventconnectionsFlue Intake Air Adapter Termination Model Kit NumberVent and air system Removing from existing ventModel Air Intake Vent Vent, air piping and termination Optional room airModel Kit Number Description Air contaminationSidewall direct venting If using the alternate sidewall terminationVent/air termination sidewall Determine location3AClearance to Gravity Air Inlets Seal all wall cavities Prepare wall penetrationsTermination and fittings Prepare wall penetrations Alternate Field Supplied OptionMultiple vent/air terminations Description and usage Sidewall termination installationSidewall termination optional concentric vent Models 151 11 Concentric Multiventing sidewall terminations 13Concentric Vent Sidewall AttachmentVent/air termination vertical Vertical direct ventingMultiple vent/air terminations Prepare roof penetrationsVertical termination optional concentric vent Models 151 Vertical termination installationMinimum Combustion AIR Typical Multiventing vertical terminationsConcentric Venting Arrangement Alternate vertical concentric venting10Existing Vent as a Chase Existing vent as a chaseFlow switch adjustment Flow switch and relief valve installationSystem piping System water piping methodsWater chemistry ScaldingPiping components 4Single Heater Single Tank 2 Temperature Cold Water Supply Cold Water Supply Number of Units Model 8Double Heater Double Tank Gas connections Connecting gas supply pipingPropane gas Natural gasLength of Pipe in Straight Feet for 1/2 PSI Single Unit Natural Gas Pipe Capacity ChartCheck inlet gas supply Gas pressure Gas valve replacementInstallation must comply with Field wiringLine voltage connections Low voltage connectionsLouver proving switch Tank thermostat Low gas pressure switchHigh gas pressure switch Flow switchRuntime contacts Alarm contactsWiring of the cascade 3Low Voltage Field Wiring Connections Condensate drain Condensate disposalCheck for gas leaks Inspect/fill condensate system Start-upChlorine concentration less than 200 ppm Inspect/check condensate lines and fittingsStart the water heater Final checks before starting the water heaterIf water heater does not start correctly Check system and water heaterFor Your Safety Read Before Operating 3Operating Instructions Models 400 Verify WHR circulator mode Set tank set point temperatureSet water heater operation Natural Gas PropaneSet clock Configuration of the cascadeGeneral Operating informationWater heater temperature regulation Cascade InstallerSequence of the cascade UserOperation Display Sequence of operation1Control Panel Armor water heater control moduleWater heater Information Dial Function Owner maintenance Maintenance Maintenance and annual startupService technician Maintenance Check all water heater wiring Check ignition ground wiringCheck control settings Check water systemCleaning heat exchanger Check flame signalPerform start-up and checks Check burner flameModel Kit Part Component Number Description Check Delta TOiled bearing circulators PC Interface Diagrams2Wiring Diagram Page Page AWII-I-O Rev C
Related manuals
Manual 16 pages 16.89 Kb

151 specifications

Lochinvar 151,286 is a notable model in the realm of commercial water heating solutions, designed primarily for large-scale applications. This model incorporates advanced technologies and features that set it apart in terms of efficiency, usability, and reliability.

One of the hallmark features of Lochinvar 151,286 is its high-efficiency system that leverages condensing technology. This technology enables the unit to extract additional heat from exhaust gases, allowing it to operate at an impressive annual fuel utilization efficiency (AFUE) rating. This not only reduces energy consumption, but it also significantly lowers operational costs.

The Lochinvar 151,286 is equipped with a robust stainless steel heat exchanger, which provides both durability and enhanced thermal efficiency. This design withstands the rigors of high-demand environments, making it ideal for restaurants, schools, hospitals, or any facility requiring consistent hot water supply. Its compact footprint allows it to be installed in tight spaces without sacrificing performance.

Another standout characteristic is its intelligent control system. The built-in touchscreen interface offers users an intuitive way to manage settings, monitor performance, and troubleshoot issues. This smart technology aids in simplifying maintenance and improves overall system reliability. The unit also features advanced safety protocols, including multiple sensors that monitor operation and provide alerts in case of irregular performance.

In terms of capacity, the Lochinvar 151,286 can deliver an impressive output, accommodating varying demands with ease. Its innovative modulation capabilities allow the unit to adjust its heating output based on real-time hot water needs, ensuring unmatched comfort and efficiency.

Supporting the model’s performance are versatile connectivity options. Lochinvar 151,286 can integrate seamlessly with building management systems, allowing facility managers to monitor and control heating processes remotely. This level of connectivity not only enhances control but also supports energy-saving strategies across the facility.

In conclusion, Lochinvar 151,286 stands out as a premium choice for commercial water heating needs. With its high-efficiency ratings, durable construction, intelligent control system, impressive capacity, and versatile connectivity, it ensures that hot water is delivered reliably and efficiently, meeting the demands of modern businesses while reducing energy costs. This combination of technology and design makes it an essential component for any large-scale facility focused on performance and sustainability.