Lennox International Inc WING manual Specifications Heat Pump

Page 10

SPECIFICATIONS HEAT PUMP

OUTDOOR UNIT WITH AXIAL FAN

R-22

MODEL

 

 

 

WING

WING

WING

WING

 

 

 

2,8TB

3TB

4TB

5TB

Cooling capacity

(*)

 

W

7.350

9.250

11.600

13.700

Heating capacity

(**)

 

W

7.800

9.000

12.100

14.600

OUTDOOR UNIT

 

 

KJB 2,8

KJB 3

KJB 4

KJB 5

COMPRESSOR

Nª / Type

 

 

1 / ALT.

1 / ALT.

1 / ALT.

1 / ALT.

FAN

 

 

 

 

 

 

 

Air flow outdoor unit

m3/h.

 

3.100

3.100

5.400

5.600

 

 

 

REFRIGERANT

Type / R-22

gr.

 

1775

2500

2800

3500

EXPANSIÓN

 

 

 

Capillary

Capillary

Capillary

Restrictor

WEIGHT

 

Kg

 

81

83

99

129

DIMENSIONS

 

mm.

 

781

781

1035

1330

Height

 

 

 

 

 

 

 

 

1005

Width

 

mm.

 

973

973

973

 

 

 

 

 

 

 

Depth

 

mm.

 

333

333

333

386

PACKING DIMENSIONS

mm.

 

845 x 1060 x 385

1085 x 1275

1495 x 1057

 

x 385

 

 

 

 

 

 

x 430

REFRIGERANT COUPLING

 

 

3/8"

3/8"

3/8"

1/2"

Líquid pipe

 

 

 

Gas pipe

 

 

 

5/8"

3/4"

3/4"

3/4"

INDOOR UNIT

 

LTX 3

LTX 3

LTX 5

LTX 5

FAN

Max.

1.300

1.300

2.100

2.100

Air flow indoor unit

m3/h.

 

 

 

 

 

Min.

1.100

1.100

1.800

1.800

WEIGHT

Kg

40

40

57

57

DIMENSIONS

mm.

 

 

 

 

Height

267

267

312

312

Width

mm.

1.409

1.409

1.719

1.719

 

 

Depth

mm.

656

656

756

756

PACKING DIMENSIONS

mm.

310 x 1430 x 680

352 x 1749 x 776

REFRIGERANT COUPLING

 

 

 

 

Líquid pipe

 

3/8"

3/8"

1/2" (2)

1/2"

Gas pipe

 

3/4" (2)

3/4"

3/4"

3/4"

 

 

DB.- Dry Bulb

(*) Air entry temperature into the indoor unit 27°C DB/19 °C WBWB.- Wet Bulb

(*) Air entry temperature into the outdoor unit 35ºC DB

(**)Air entry temperature into the indoor unit 20°C DB/12 °C WB

(**)Air entry temperature into the outdoor unit 7ºC DB/6ºCWB

(1)Charge of refrigerant, factory charged on outdoor unit. See page 22, to calculate model refrigerant charge

(2)Use the coupling fittings included in indoor unit for refrigerant connection with outdoor unit..

8

Image 10
Contents Application Page Contents Páge Product Range Cooling only R-407CLTX Indoor Unit in COMBINATION, with Axial FAN Outdoor Unit Heat Pump R-22C Product Range Heat PumpOn OFF System Configuration Indoor UnitSwitch Model Cooling only OFF Heat PumpOutdoor Unit General Description Indoor Unit LTXOutdoor Unit KJF/KJB Outdoor Unit Type KJF/KJBOutdoor Unit Specifications Cooling onlyModel Indoor UnitWeight Outdoor Unit with Centrifugal FANSpecifications Heat Pump 3CB 4CB 5CB Sound Level SET with Axial FAN Outdoor UnitSound Level SET with Centrifugal FAN Outdoor UnitElectric Wiring Diagram Number of Wires X SectionElectrical Connections and System Configuration LTX Outdoor Unit Cooling onlyHeat Pump LTXAIR Flow Outdoor Unit MOTOR-FAN CharacteristicsKCF 3K / KCB 3S KCF 4K / KCB 4S KCF 5K / KCB 5SStandard Operating Limits Cooling only UnitsOperating Limits Heat Pump Units Indoor Outdoor UnitYES Distances Between Units Outdoor U Indoor U Indoor Unit ModelOutdoor Units Tipo KCF-K/ KCB Outdoor Units Type KJF-K/ KJBModel ExampleKCF-K KCB-S Setting UPMaximum Dimensions AIR OUT Standard OptionalDescription Outdoor Unit KCF-K / KCB 2,8-3 Access to Electrical BOXAIR Standard 810 Description Outdoor Unit KCF / KCB-S 4Entrance STANDARD/ Optional Outdoor Unit KCF-K / KCB KJF-K Dimensions and Setting Templates of Indoor Unit LTXKJF-K KJB LTXAIR-SWEEP Installation Indoor UnitInstallation Unit Opening in Flase CeilingIndoor Unit Optionals Electrical Heater Outdoor Unit Optionals Main Switch Winter ControlMaintenance of the Unit Possible Problems Solution Standard Guidelines to Lennox Refac equipment Page Page W. L e n n oxe u ro p e . c o m