| SPECIFICATIONS COOLING ONLY |
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
| OUTDOOR UNIT WITH CENTRIFUGAL FAN |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| MODEL |
|
|
|
| WING | WING |
| WING | WING | ||||||||
|
|
|
|
| 2,8CFK | 3CFK |
| 4CFK | 5CFK |
| ||||||||
| Cooling capacity | (*) |
|
| W | 7.180 | 9.100 |
| 12.100 | 14.000 |
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| OUTDOOR UNIT |
|
|
| KCF 2,8K | KCF 3K |
| KCF 4K | KCF 5K | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| COMPRESSOR | Nª / Type |
|
| 1 / ALT. | 1 / ALT. |
| 1 / ALT. | 1 / ALT. | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| FAN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Air flow outdoor unit | m3/h. | 2.500 | 2.500 |
| 3.400 | 5.000 |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
| Available pressure | Pa | 40 | 40 |
| 50 | 50 |
|
|
|
| |||||
| REFRIGERANT | Type / | gr. (1) | 2255 | 2350 |
| 3070 | 4950 |
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| EXPANSIÓN |
|
|
|
| Capillary | Capillary |
| Capillary | Capillary | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| WEIGHT |
|
| Kg | 89 | 91 |
| 125 | 140 |
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| DIMENSIONS |
|
| mm. | 505 | 505 |
| 525 | 575 |
|
|
|
| |||||
|
|
| Height |
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Width |
|
| mm. | 1050 | 1050 |
| 1300 | 1300 |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| Depth |
|
| mm. | 750 | 750 |
| 855 | 855 |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| PACKING DIMENSIONS |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
| mm. |
| 630 x 1140 x 850 |
|
| 775 x 1330 x 865 |
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
REFRIGERANT COUPLING
Líquid pipe |
| 3/8" | 3/8" | 3/8" | 1/2" |
Gas pipe |
| 5/8" | 3/4" | 3/4" | 3/4" |
INDOOR UNIT |
| LTX 3 | LTX 3 | LTX 5 | LTX 5 |
FAN | Max. | 1.300 | 1.300 | 2.100 | 2.100 |
Air flow indoor unit | m3/h. | 1.100 |
|
|
|
| Min. | 1.100 | 1.800 | 1.800 | |
WEIGHT | Kg | 40 | 40 | 57 | 57 |
DIMENSIONS | mm. |
|
|
|
|
Height | 267 | 267 | 312 | 312 | |
Width | mm. | 1.409 | 1.409 | 1.719 | 1.719 |
Depth | mm. | 656 | 656 | 756 | 756 |
PACKING DIMENSIONS | mm. | 310 x 1430 x 680 | 352 x 1749 x 776 | ||
REFRIGERANT COUPLING |
|
|
|
| |
Líquid pipe |
| 3/8" | 3/8" | 1/2" (2) | 1/2" |
Gas pipe |
| 3/4" (2) | 3/4" | 3/4" | 3/4" |
|
|
(*)Air entry temperature into the indoor unit 27°C DB/19 °C WB
(*)Air entry temperature into the outdoor unit 35ºC DB
(1)Charge of refrigerant, factory charged on outdoor unit. See page 22, to calculate model refrigerant charge.
(2)Use the coupling fittings included in indoor unit for refrigerant connection with outdoor unit.
DB.- Dry Bulb
WB.- Wet Bulb
7