Lennox International Inc WING manual 3CB 4CB 5CB

Page 11

SPECIFICATIONS HEAT PUMP

R-22

OUTDOOR UNIT WITH CENTRIFUGAL FAN

 

 

 

 

MODEL

 

 

 

 

 

 

 

WING

WING

WING

WING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2,8CB

3CB

4CB

5CB

 

 

 

 

Cooling capacity

 

(*)

 

 

 

W

7.180

9.100

 

12.100

14.000

 

 

 

 

 

 

 

Heating capacity

 

(**)

 

 

 

W

8.150

10.220

 

13.500

17.400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR UNIT

 

 

 

 

 

 

KCB 2,8S

KCB 3S

KCB 4S

KCB 5S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPRESSOR

Nª / Type

 

 

 

1 / ALT.

1 / ALT.

1 / ALT.

1 / ALT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Air flow outdoor unit

 

 

 

m3/h.

 

2.500

2.500

 

3.400

5.000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Available pressure

 

 

 

Pa

 

40

40

 

50

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT

Type / R-22

gr.

(1)

2425

2525

 

3400

5300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXPANSIÓN

 

 

 

 

 

 

 

Capillary

Capillary

Capillary

Capillary

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WEIGHT

 

 

 

 

Kg

 

92

94

 

135

150

 

 

 

 

 

 

 

DIMENSIONS

 

 

 

 

mm.

 

505

505

 

525

575

 

 

 

 

 

 

 

 

 

 

 

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Width

 

 

 

 

mm.

 

1050

1050

 

1300

1300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Depth

 

 

 

 

mm.

 

750

750

 

855

855

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

mm.

 

 

 

 

 

 

 

 

 

 

 

 

 

PACKING DIMENSIONS

 

 

 

 

 

630 x 1140 x 850

 

775 x 1330 x 865

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT COUPLING

Líquid pipe

 

3/8"

3/8"

3/8"

1/2"

Gas pipe

 

5/8"

3/4"

3/4"

3/4"

INDOOR UNIT

 

LTX 3

LTX 3

LTX 5

LTX 5

FAN

Max.

1.300

1.300

2.100

2.100

Air flow indoor unit

m3/h.

 

 

 

 

 

Min.

1.100

1.100

1.800

1.800

WEIGHT

Kg

40

40

57

57

DIMENSIONS

 

 

 

 

 

Height

mm.

267

267

312

312

Width

mm.

1.409

1.409

1.719

1.719

 

 

Depth

mm.

656

656

756

756

PACKING DIMENSIONS

mm.

310 x 1430 x 680

352 x 1749 x 776

REFRIGERANT COUPLING

 

 

 

 

Líquid pipe

 

3/8"

3/8"

1/2" (2)

1/2"

Gas pipe

 

3/4" (2)

3/4"

3/4"

3/4"

DB.- Dry Bulb

(*) Air entry temperature into the indoor unit 27°C DB/19 °C WBWB.- Wet Bulb

(*) Air entry temperature into the outdoor unit 35ºC DB

(**)Air entry temperature into the indoor unit 20°C DB/12 °C WB

(**)Air entry temperature into the outdoor unit 7ºC DB/6ºCWB

(1)Charge of refrigerant, factory charged on outdoor unit. See page 22, to calculate model refrigerant charge

(2)Use the coupling fittings included in indoor unit for refrigerant connection with outdoor unit..

9

Image 11
Contents Application Page Contents Páge LTX Indoor Unit in COMBINATION, with Axial FAN Outdoor Unit Cooling only R-407CProduct Range Product Range Heat Pump Heat Pump R-22CModel Cooling only OFF Heat Pump System Configuration Indoor UnitSwitch On OFFOutdoor Unit Type KJF/KJB General Description Indoor Unit LTXOutdoor Unit KJF/KJB Outdoor UnitIndoor Unit Specifications Cooling onlyModel Outdoor UnitOutdoor Unit with Centrifugal FAN WeightSpecifications Heat Pump 3CB 4CB 5CB SET with Axial FAN Outdoor Unit Sound LevelSET with Centrifugal FAN Outdoor Unit Sound LevelNumber of Wires X Section Electric Wiring DiagramElectrical Connections and System Configuration LTX Cooling onlyHeat Pump LTX Outdoor UnitKCF 4K / KCB 4S KCF 5K / KCB 5S Outdoor Unit MOTOR-FAN CharacteristicsKCF 3K / KCB 3S AIR FlowOperating Limits Heat Pump Units Operating Limits Cooling only UnitsStandard YES Outdoor UnitIndoor Outdoor U Indoor U Indoor Unit Model Distances Between UnitsExample Outdoor Units Type KJF-K/ KJBModel Outdoor Units Tipo KCF-K/ KCBAIR OUT Standard Optional Setting UPMaximum Dimensions KCF-K KCB-SAIR Standard Access to Electrical BOXDescription Outdoor Unit KCF-K / KCB 2,8-3 Description Outdoor Unit KCF / KCB-S 4 810Entrance STANDARD/ Optional Outdoor Unit KCF-K / KCB LTX Dimensions and Setting Templates of Indoor Unit LTXKJF-K KJB KJF-KOpening in Flase Ceiling Installation Indoor UnitInstallation Unit AIR-SWEEPIndoor Unit Optionals Electrical Heater Winter Control Outdoor Unit Optionals Main SwitchMaintenance of the Unit Possible Problems Solution Standard Guidelines to Lennox Refac equipment Page Page W. L e n n oxe u ro p e . c o m