Lennox International Inc WING manual Setting UP, Maximum Dimensions, Kcf-K Kcb-S, AIR Optional

Page 22

DIMENSIONS OF OUTDOOR UNIT WITH CENTRIFUGAL FAN (mm.)

 

MODELS

MAXIMUM DIMENSIONS

KCF-K / KCB-S 2,8-3

 

A

A

B C B

MODELS

KCF-K / KCB-S- 4-5

A

BC

C

KCF-K

2,8-3

4

5

KCB-S

 

 

 

 

 

 

 

A

490

525

575

 

 

 

 

B

1050

1300

1300

 

 

 

 

C

750

830

830

 

 

 

 

A

505

525

575

 

 

 

 

B

1100

1300

1300

 

 

 

 

C

841

890

890

 

 

 

 

SETTING UP

TEMPLATE (mm) UNITS 2-2,5-2,8-3

AIR OUT

AIR IN

STANDARD

STANDARD

 

A

AIR OUT

OPTIONAL

B

B

Use 4 rod of a diameter of 10mm if the unit is fixed in the roof , or screw M.10 if the unit is fixed on the ground.

AIR IN

OPTIONAL

 

 

 

 

 

Dimensions recommended on

 

 

 

 

 

point A and B are refered to the

 

A

 

B

 

hole of support of the unit.

 

 

 

 

 

 

 

 

 

 

 

 

 

KCF / KCB-S- 2,8 - 3

1064

 

660

 

 

 

 

 

 

 

 

A

B

 

20

Image 22
Contents Application Page Contents Páge Product Range Cooling only R-407CLTX Indoor Unit in COMBINATION, with Axial FAN Outdoor Unit Heat Pump R-22C Product Range Heat PumpOn OFF System Configuration Indoor UnitSwitch Model Cooling only OFF Heat PumpOutdoor Unit General Description Indoor Unit LTXOutdoor Unit KJF/KJB Outdoor Unit Type KJF/KJBOutdoor Unit Specifications Cooling onlyModel Indoor UnitWeight Outdoor Unit with Centrifugal FANSpecifications Heat Pump 3CB 4CB 5CB Sound Level SET with Axial FAN Outdoor UnitSound Level SET with Centrifugal FAN Outdoor UnitElectric Wiring Diagram Number of Wires X SectionElectrical Connections and System Configuration LTX Outdoor Unit Cooling onlyHeat Pump LTXAIR Flow Outdoor Unit MOTOR-FAN CharacteristicsKCF 3K / KCB 3S KCF 4K / KCB 4S KCF 5K / KCB 5SStandard Operating Limits Cooling only UnitsOperating Limits Heat Pump Units Indoor Outdoor UnitYES Distances Between Units Outdoor U Indoor U Indoor Unit ModelOutdoor Units Tipo KCF-K/ KCB Outdoor Units Type KJF-K/ KJBModel ExampleKCF-K KCB-S Setting UPMaximum Dimensions AIR OUT Standard OptionalDescription Outdoor Unit KCF-K / KCB 2,8-3 Access to Electrical BOXAIR Standard 810 Description Outdoor Unit KCF / KCB-S 4Entrance STANDARD/ Optional Outdoor Unit KCF-K / KCB KJF-K Dimensions and Setting Templates of Indoor Unit LTXKJF-K KJB LTXAIR-SWEEP Installation Indoor UnitInstallation Unit Opening in Flase CeilingIndoor Unit Optionals Electrical Heater Outdoor Unit Optionals Main Switch Winter ControlMaintenance of the Unit Possible Problems Solution Standard Guidelines to Lennox Refac equipment Page Page W. L e n n oxe u ro p e . c o m