Lennox International Inc 4HP18LT manual System Diagnostic Module, LED Description

Page 20

System Diagnostic Module

4HP18LT units contain a diagnostic module for troubleshouting heat pump system failures. By monitoring and analyzing data from the compressor and thermostat demand, the module can accurately detect the cause of electrical and system related failure without any sensors. If a system problem occurs, a flashing LED indicator communicates the failure code.

LED Description

POWER LED (Green) indicates voltage is present at the power connection of the module.

ALERT LED (Yellow) communicates an abnormal system condition through a unique flash code. The ALERT LED will flash a number of times consecutively, pause, and then repeat the process. The number of consecutive flashes correlates to a paticular abnormal condition.

TRIP LED (Red) indicates there is a demand signal from the thermostat but no current to the compressor is detected by the module. The TRIP LED typically indicates the compressor protector is open or may indicate missing supply power to the compressor.

Interpreting the Diagnostic LEDs

When an abnormal system condition occurs, the diagnostic nodule displays the appropriate ALERT and/or TRIP LED. The yellow ALERT LED will flash a number of times consecutively, pause, and then repeat the process. To identify a slash code number, count the number of consecutive flashes. Refer to Table 10 below and Table 11 on page 20 for information on the flash codes.

Flash Codes

Table 10

506470-01

Issue 1007

Page 20

Image 20
Contents Save these instructions for future reference Lennox International Inc. CompanyInstallation Installation ClearancesGeneral Torque TableElectrical Wiring Slab MountingSlab Mounting Roof MountingInstalling Refrigerant Line Refrigerant PipingPlacement Outside Unit Placement & InstallationLine Set Isolation Refrigerant Line Set DiametersRefrigerant Line Sets Installing Horizontal Runs Refrigerant Line Sets Transition from Vertical to Horizontal Flushing Procedure Required EuipmentRefrigerant Metering Device Expansion Valve SystemsTo Access the Schrader Port To Close Liquid or Suction Line Service ValveUsing an Electronic Leak Detector EvacuationIssue Refrigerant Charging Refrigerant Charge AdjustmentSTART-UP Issue R410A Temperature/Pressure Chart Approach Values for TXV Systems Issue Operation Defrost Control Timing Pins Compressor DelayTime Delay Pressure Switch CircuitLED Description System Diagnostic ModuleInterpreting the Diagnostic LEDs 24VAC Power Wiring Thermostat Demand Wiring Miswired Module CodesMaintenance Homeowner Information Inspect and clean outdoor coilTemperature Setting Levers Fan Switch System SwitchTemperature Indicator Indicating LightStart-Up and Performance Checklist Wire Diagram Issue