Fast EtherHub 3500 System User’s Guide

After power on, the hub automatically performs a diagnostic test. The diagnostic tests display results for the repeater board via the Partition/Disable LEDs on the front panel. Test results for the agent board can only be seen via a console connection to the serial port. The following table shows how test results for the repeater board are indicated by the Partition/Disable LEDs.

Partition/Disabled

LED Indicator

1

2

3

4

5

7

8

9

10

11

12

Test Function/Component

of Repeater Board

Boot ROM

Hub Configuration EEPROM

RAM for Repeater Board CPU

Repeater Information Base SRAM

Repeater Interface Controller

Routing Table for Internal SEM Port

Input Queue for Internal SEM Port

Output Queue for Internal SEM Port

Routing Table for External SEM Port

Input Queue for External SEM Port

Output Queue for External SEM Port

Table 5.16 Diagnostic Results for Repeater Board

The system tests each component one at a time. The corresponding indicator will display a blinking light (ON) after test completion to show which component failed the test. The unit will complete the test cycle even if a problem is detected on any component. If all Partition/Disable LEDs are off, then all the tested components have successfully passed diagnostics. You must have a console connected to serial port to view the results of diagnostic testing for the agent board.

5-12

Hardware Reference

Page 113
Image 113
Accton Technology 12i, 12mi SNMP manual Diagnostic Results for Repeater Board