Fast EtherHub 3500 System User’s Guide
Configuring the System 4-7
2. The login procedure for the Fast EtherHub-12i configuration
program requires a password only. Access priviledges are
Read/Write, and the default password is “admin.”
When logging into the Fast EtherHub-12mi configuration
program, you must provide both a user name and password.
The default user names are “admin” and “guest.��� The
Administrator account has read/write access, and the Guest
has read-only access. For initial configurations, the
password is blank. Just press the <Enter> key.
Administrator is the h ighest privilege level in t h e Fast
EtherHub-12mi configuration program. The admini s tr at o r
should define a password, record it and put it in a safe place.
If you have not already done so, select the User Passwords
field under the Configuration Panel and enter a password.
The configuration parameters you can access after logging
into the system are described in the following section.
Using the Fast EtherHub 3500 System Configuration Program
Accton provides a proprietary, user-friendly, menu driven on-
board configuration program (i.e., the Fast EtherHub 3500
System Configuration Program). The configuration program
differs for the Fast EtherHub-12i and the Fast EtherHub-12mi.
The connection types allowed and options provided by this
configuration program are summarized below:
The Fast EtherHub-12i is designed as a manageable hub,
without an on-board SNMP agent. Therefore, when an
SNMP agent (i.e., the Fast EtherHub-12mi) is connected to
this hub via the backplane bus, its management port will be
disabled, and configuration must be carried out using the
agent. However, if this hub is not connected to an agent, you
can configure it by making a direct connection to the
management port.