Pentair ThermalFlo important safety instructions Dealer for advice. Call the factory for advice

Page 34

26

Problem

PossibleCause

CorrectiveAction

 

 

 

Remote, Pool or Spa light ON.

Low or restricted water flow through heater. Dirty

Clean entire filtering system and or replace filter

Water Pressure light ON.

or worn filters or clogged lint traps. Clogged

element. Inspect & clean pump impeller. Adjust all

Thermostat light OFF.

filter pump impeller. Improper plumbing valve

plumbing valves. Repair suction air leaks, grease

EO1 Error

settings. Suction leak allowing air into the water

pump lid o-ring. Replace filter. Wrong filter pump pipe

Unit will not run.

flow. Low water flow when switched to spa mode.

size. Automatic pool vacuum causing restriction.

 

Unit is plumbed backwards. Heat exchanger

Recharge refrigerant if required.

 

clogged with debris. Internal bypass valve

Call your dealer for advise. Call the factory for advise.

 

damaged or clogged with debris. Refrigerant

 

 

system malfunction.

 

 

 

 

Remote, Pool or Spa light ON.

Low or restricted water flow through heater. Dirty

Clean entire filtering system and or replace filter

Water Pressure light ON.

or worn filters or clogged lint traps. Clogged

element. Inspect & clean pump impeller. Adjust all

Thermostat light ON.

filter pump impeller. Improper plumbing valve

plumbing valves. Repair suction air leaks, grease

Unit is cycling on & off.

settings. Suction leak allowing air into the water

pump lid o-ring. Replace filter. Wrong filter pump pipe

 

flow. Low water flow when switched to spa mode.

size. Automatic pool vacuum causing restriction.

 

Unit is plumbed backwards. Heat exchanger

Call your dealer for advise. Call the factory for advise.

 

clogged with debris. Internal bypass valve

 

 

damaged or clogged with debris. Fan cycling.

 

 

 

 

Remote, Pool or Spa light ON.

Low water flow through heater. Dirty or worn

Clean entire filtering system and or replace filter

Water Pressure light ON.

filters or clogged lint traps. Clogged filter pump

element. Inspect & clean pump impeller. Adjust

Thermostat light ON.

impeller. Improper plumbing valve settings.

plumbing valves. Adjust water pressure switch.

Fan is not turning.

 

Call the factory for advice.

Unit will not start.

 

 

 

 

 

All control lights ON.

Compressor has not started yet. Low water flow

Wait for the 5 minute compressor time delay. Clean

Fan is turning, no cool air

through heater. Dirty or worn filters or clogged

entire filtering system and or replace filter element.

discharging out the top of heater.

lint traps. Clogged filter pump impeller. Improper

Inspect & clean pump impeller. Adjust plumbing valves.

Unit is not heating.

plumbing valve settings.

Call factory or dealer.

 

 

 

Spa will not heat to maximum

Low or restricted water flow through heater.

Clean entire filtering system and or replace filter

temperature of 104° F.

Dirty or worn filters or clogged lint traps. Clogged

element. Inspect & clean pump impeller. Adjust all

Thermostat is turned all the way up.

filter pump impeller. Improper plumbing valve

plumbing valves. Repair suction air leaks, grease

 

settings. Suction leak allowing air into the water

pump lid o-ring. Shut off air blower and or Venturi

OR

flow. Low water flow when switched to spa mode

inlets that allow air turbulence in the spa. Use a cover

 

or the control is not in spa mode. Unit is plumbed

while heating the spa. Outside air temp. too cold. Set

Spa is heating very slowly.

backwards. Heat exchanger clogged with debris.

spa pump timer for longer time. Call your dealer for

 

Internal bypass valve damaged or clogged with

advice. Call the factory for advice.

 

debris. Your spa thermometer is not reading the

 

 

correct temperature. Air blower is running.

 

 

Venturi air inlets are open. It is very cold outside.

 

 

Spa pump is not running.

 

 

 

 

Pool is heating very slowly.

Low or restricted water flow through heater.

Clean entire filtering system and or replace filter

Pool is not getting up to temperature.

Dirty or worn filters or clogged lint traps. Clogged

element. Inspect & clean pump impeller. Adjust all

 

filter pump impeller. Improper plumbing valve

plumbing valves. Repair suction air leaks, grease

 

settings. Suction leak allowing air into the water

pump lid o-ring. Use a pool cover. Place a wind break

 

flow. It is cold outside. Pool pump timer is not set

around pool. Set pool pump timer longer. Call your

 

for a long enough running period. Pool is not

dealer for advice. Call the factory for advice.

 

covered. High wind speed over pool. Shaded

 

 

pool area.

 

 

 

 

ThermalFlo Installation and User’s Guide

Image 34
Contents ThermalFlo Customer Service Web siteContents Illustrated Parts Replacement Parts List Important Notice Codes and StandardsImportant Safety Precautions Consumer Information and SafetySwimming Pool Energy Saving Tips General Specifications General Installation InformationWarranty Information Section Introduction ThermalFlo OverviewGeneral Features Installing the ThermalFlo Section InstallationMaterials needed for Installation ThermalFlo Heat Pump Dimensions LocationRoof Run-off ClearancesEquipment Pad Drainage and Condensation Anchor Clamps InstallationLawn Sprinklers Water Connections Plumbing layoutWater Connections at the Heat Pump Check Valve InstallationAutomatic Flow Control Valve Multiple Unit Installation Heat Pump, Heater and/or Solar CombinationMultiple Heat Pump Connections To PoolGeneral Information Main PowerElectrical Connections BondingWiring Diagram 460812, 460813, 460814, 460815, 460822Relay Remote Controls Heat Pump Control BoardBLK GRN YEL RED Initial Start-up Precautions Section Operating ThermalFloOperating the Controller Water Pressure Thermostat Heating CoolingSystem Indicator LEDs Indicator Lights / LEDsMode Indicator LEDs Operation Temperature SettingMode Selection Buttons Keypad LockoutTroubleshooting Code Name CauseWater Pressure Switch Adjustment Water Chemistry Section General MaintenanceWinterizing Spring Start-Up Inspection and ServiceOwner Inspection Professional Maintenance and Service AIRThermalFlo Installation and User’s Guide Section Troubleshooting Remote, Pool or Spa light onDealer for advice. Call the factory for advice Pressure Section Replacement Parts Illustrated PartsReplacement Parts List 25 473026 Compressor Isolation KIT, Grommet & Spacer 1 SETThermalFlo Installation and User’s Guide Page 473426 Rev. C 10/19/06

ThermalFlo specifications

Pentair ThermalFlo is a leading-edge solution designed to address the evolving demands of thermal management in various industrial applications. As organizations prioritize energy efficiency and temperature regulation, ThermalFlo emerges as a robust offering from Pentair, a global leader in water and fluid management.

One of the standout features of Pentair ThermalFlo is its innovative heat tracing technology. This system employs electrical heat tracing cables that are strategically engineered to maintain desired temperatures in pipes, valves, and other critical components. The design minimizes the risks of freezing, ensuring that fluids can flow seamlessly, even in harsh environments. Moreover, it enhances safety by reducing the likelihood of pipe bursts due to thermal stress.

ThermalFlo also incorporates advanced insulation technologies that complement its heat tracing capabilities. The combination of these two approaches ensures optimal energy efficiency, reducing heat loss and lowering operational costs. When used in conjunction with smart monitoring systems, organizations can achieve real-time temperature control, allowing for proactive adjustments that enhance system efficiency.

Another significant characteristic of Pentair ThermalFlo is its versatility. This solution can be customized to suit various applications, from oil and gas industries to food processing and pharmaceuticals. The adaptability of ThermalFlo makes it an ideal choice for facilities looking to improve their thermal strategies without compromising on performance.

In addition to its technical features, Pentair ThermalFlo emphasizes sustainability. By promoting energy efficiency and reducing heat loss, the system contributes to lower carbon footprints for its users. This aligns with the growing trend of adopting environmentally responsible practices within industry, showcasing Pentair’s commitment to innovative solutions that meet modern challenges.

Furthermore, the installation and maintenance of ThermalFlo systems are streamlined, with user-friendly features that simplify the process for engineers and technicians. Its robust design ensures long-lasting performance, reducing downtime and maintenance costs over time.

In conclusion, Pentair ThermalFlo stands out in the marketplace through its blend of innovative technologies, energy efficiency, and adaptability across different industries. As businesses increasingly seek effective thermal management solutions, ThermalFlo represents an investment in reliability, safety, and sustainability.