Pentair ThermalFlo important safety instructions Relay Remote Controls, Heat Pump Control Board

Page 21

13

Relay Remote Controls

Electrical wiring must be in accordance with the latest edition of the NEC (NFPA 70) in the United States and CEC (CSA 22.1) in Canada, unless local code requirements indicate otherwise. To connect remote control equipment to the heat pump, perform the following steps:

1.Turn off the power to both the remote pool/spa control system and the heat pump.

2.Remove the front left panel of the heat pump cabinet, (you do not need to remove the torque head screw at the top left corner).

3.Removetheelectricalservicepaneltotheheatpump.Removethe4bezelretainingscrewsfromabovethe electricalcompartmentandrotatethebezeldownward.ThiswillallowyoutoaccesstheRemoteterminals on the back of the ThermalFlo HP control board for the remote control installation.

4.Run the wires from the pool/spa remote control system into the upper electrical compartment.

5.Connectthewiringfromthepool/sparemotecontrolsystemtotheheatpumpremotecontrolterminalsusing ¼ in. “Fast On” connectors as shown in the figure below.

6.Rotate the bezel back upwards into position and reinstall the 4 retaining screws.

7.Replacetheelectricalservicepanel.

8.Replacethefrontleftpanel.

9.Restore power to the heat pump and the pool/spa remote control system.

REMOTE

SPA POOL

Heat Pump Control Board

TEMPERATURE THERMISTER

WATER

FLOW

PRES

HI

LOWPRES

H C AU

24 VAC

SPA

COM POOL

FA

N

COMPRESSORSOLENOID

 

 

(3)Fast-On Connectors

Figure 12.

ThermalFlo Installation and User’s Guide

Image 21
Contents ThermalFlo Web site Customer ServiceContents Illustrated Parts Replacement Parts List Codes and Standards Important NoticeConsumer Information and Safety Important Safety PrecautionsSwimming Pool Energy Saving Tips General Installation Information General SpecificationsWarranty Information ThermalFlo Overview Section IntroductionGeneral Features Section Installation Installing the ThermalFloMaterials needed for Installation Location ThermalFlo Heat Pump DimensionsClearances Roof Run-offEquipment Pad Anchor Clamps Installation Drainage and CondensationLawn Sprinklers Plumbing layout Water ConnectionsCheck Valve Installation Water Connections at the Heat PumpAutomatic Flow Control Valve Heat Pump, Heater and/or Solar Combination Multiple Unit InstallationTo Pool Multiple Heat Pump ConnectionsElectrical Connections Main PowerGeneral Information Bonding460812, 460813, 460814, 460815, 460822 Wiring DiagramHeat Pump Control Board Relay Remote ControlsBLK GRN YEL RED Section Operating ThermalFlo Initial Start-up PrecautionsWater Pressure Thermostat Heating Cooling Operating the ControllerIndicator Lights / LEDs System Indicator LEDsMode Indicator LEDs Mode Selection Buttons Temperature SettingOperation Keypad LockoutCode Name Cause TroubleshootingWater Pressure Switch Adjustment Section General Maintenance Water ChemistryWinterizing Inspection and Service Spring Start-UpOwner Inspection AIR Professional Maintenance and ServiceThermalFlo Installation and User’s Guide Remote, Pool or Spa light on Section TroubleshootingDealer for advice. Call the factory for advice Pressure Illustrated Parts Section Replacement Parts25 473026 Compressor Isolation KIT, Grommet & Spacer 1 SET Replacement Parts ListThermalFlo Installation and User’s Guide Page 473426 Rev. C 10/19/06

ThermalFlo specifications

Pentair ThermalFlo is a leading-edge solution designed to address the evolving demands of thermal management in various industrial applications. As organizations prioritize energy efficiency and temperature regulation, ThermalFlo emerges as a robust offering from Pentair, a global leader in water and fluid management.

One of the standout features of Pentair ThermalFlo is its innovative heat tracing technology. This system employs electrical heat tracing cables that are strategically engineered to maintain desired temperatures in pipes, valves, and other critical components. The design minimizes the risks of freezing, ensuring that fluids can flow seamlessly, even in harsh environments. Moreover, it enhances safety by reducing the likelihood of pipe bursts due to thermal stress.

ThermalFlo also incorporates advanced insulation technologies that complement its heat tracing capabilities. The combination of these two approaches ensures optimal energy efficiency, reducing heat loss and lowering operational costs. When used in conjunction with smart monitoring systems, organizations can achieve real-time temperature control, allowing for proactive adjustments that enhance system efficiency.

Another significant characteristic of Pentair ThermalFlo is its versatility. This solution can be customized to suit various applications, from oil and gas industries to food processing and pharmaceuticals. The adaptability of ThermalFlo makes it an ideal choice for facilities looking to improve their thermal strategies without compromising on performance.

In addition to its technical features, Pentair ThermalFlo emphasizes sustainability. By promoting energy efficiency and reducing heat loss, the system contributes to lower carbon footprints for its users. This aligns with the growing trend of adopting environmentally responsible practices within industry, showcasing Pentair’s commitment to innovative solutions that meet modern challenges.

Furthermore, the installation and maintenance of ThermalFlo systems are streamlined, with user-friendly features that simplify the process for engineers and technicians. Its robust design ensures long-lasting performance, reducing downtime and maintenance costs over time.

In conclusion, Pentair ThermalFlo stands out in the marketplace through its blend of innovative technologies, energy efficiency, and adaptability across different industries. As businesses increasingly seek effective thermal management solutions, ThermalFlo represents an investment in reliability, safety, and sustainability.