16

Operating the Controller

An advanced microprocessor based controller that provides a sophisticated yet simple interface to operate your heat pump for maximum efficiency and enjoyment of your pool, controls the ThermalFlo HP heat pump. It will control incoming water temperature between a minimum of 60º and a maximum of 104º F. The controller also serves as system status indicator, using LED lights and error codes, see Figure 15.

During normal operation, the controller displays the temperature of the water returning to the heat pump. Changing the desired pool or spa temperature is easily done by simply pressing the appropriate “Up” or “Down” arrow until the display reads the desired temperature. The display returns to current water temperature when setpoint adjustment is complete.

Todisplaythecurrentsetpoint,simplytouchtheappropriate“Up”or“Down”arrow. Thedisplaywillmomentarily display the current setpoint. Note that the POOL LED must be on to display or adjust the pool setpoint and the SPA LED must be on to display or adjust the spa setpoint.

WATER PRESSURE

THERMOSTAT

HEATING

COOLING

ERROR CODES:

E01

- Low Refrigerant Pressure

E02

- High Refrigerant Pressure

E03

- Remote Error

E04

- Switch Fault

Err

- Thermistor Error

LO

- Water Temperature Low

HI

- Water Temperature High

TEMPERATURE SETTING

AUTO- HEAT/COOL

POOL

SPA

PRESS ANY ARROW ONCE TO

CHECK SET TEMPERATURE

Figure 15. Main Control Panel

ThermalFlo Installation and User’s Guide

Image 24
Contents ThermalFlo Customer Service Web siteContents Illustrated Parts Replacement Parts List Important Notice Codes and StandardsImportant Safety Precautions Consumer Information and SafetySwimming Pool Energy Saving Tips General Installation Information General SpecificationsWarranty Information Section Introduction ThermalFlo OverviewGeneral Features Section Installation Installing the ThermalFloMaterials needed for Installation ThermalFlo Heat Pump Dimensions LocationClearances Roof Run-offEquipment Pad Anchor Clamps Installation Drainage and CondensationLawn Sprinklers Water Connections Plumbing layoutCheck Valve Installation Water Connections at the Heat PumpAutomatic Flow Control Valve Multiple Unit Installation Heat Pump, Heater and/or Solar CombinationMultiple Heat Pump Connections To PoolMain Power Electrical ConnectionsGeneral Information BondingWiring Diagram 460812, 460813, 460814, 460815, 460822Relay Remote Controls Heat Pump Control BoardBLK GRN YEL RED Initial Start-up Precautions Section Operating ThermalFloOperating the Controller Water Pressure Thermostat Heating CoolingIndicator Lights / LEDs System Indicator LEDsMode Indicator LEDs Temperature Setting Mode Selection ButtonsOperation Keypad LockoutTroubleshooting Code Name CauseWater Pressure Switch Adjustment Section General Maintenance Water ChemistryWinterizing Inspection and Service Spring Start-UpOwner Inspection Professional Maintenance and Service AIRThermalFlo Installation and User’s Guide Section Troubleshooting Remote, Pool or Spa light onDealer for advice. Call the factory for advice Pressure Section Replacement Parts Illustrated PartsReplacement Parts List 25 473026 Compressor Isolation KIT, Grommet & Spacer 1 SETThermalFlo Installation and User’s Guide Page 473426 Rev. C 10/19/06

ThermalFlo specifications

Pentair ThermalFlo is a leading-edge solution designed to address the evolving demands of thermal management in various industrial applications. As organizations prioritize energy efficiency and temperature regulation, ThermalFlo emerges as a robust offering from Pentair, a global leader in water and fluid management.

One of the standout features of Pentair ThermalFlo is its innovative heat tracing technology. This system employs electrical heat tracing cables that are strategically engineered to maintain desired temperatures in pipes, valves, and other critical components. The design minimizes the risks of freezing, ensuring that fluids can flow seamlessly, even in harsh environments. Moreover, it enhances safety by reducing the likelihood of pipe bursts due to thermal stress.

ThermalFlo also incorporates advanced insulation technologies that complement its heat tracing capabilities. The combination of these two approaches ensures optimal energy efficiency, reducing heat loss and lowering operational costs. When used in conjunction with smart monitoring systems, organizations can achieve real-time temperature control, allowing for proactive adjustments that enhance system efficiency.

Another significant characteristic of Pentair ThermalFlo is its versatility. This solution can be customized to suit various applications, from oil and gas industries to food processing and pharmaceuticals. The adaptability of ThermalFlo makes it an ideal choice for facilities looking to improve their thermal strategies without compromising on performance.

In addition to its technical features, Pentair ThermalFlo emphasizes sustainability. By promoting energy efficiency and reducing heat loss, the system contributes to lower carbon footprints for its users. This aligns with the growing trend of adopting environmentally responsible practices within industry, showcasing Pentair’s commitment to innovative solutions that meet modern challenges.

Furthermore, the installation and maintenance of ThermalFlo systems are streamlined, with user-friendly features that simplify the process for engineers and technicians. Its robust design ensures long-lasting performance, reducing downtime and maintenance costs over time.

In conclusion, Pentair ThermalFlo stands out in the marketplace through its blend of innovative technologies, energy efficiency, and adaptability across different industries. As businesses increasingly seek effective thermal management solutions, ThermalFlo represents an investment in reliability, safety, and sustainability.