Pentair Section Operating ThermalFlo, Initial Start-up Precautions

Page 23

15

Section 3

Operating ThermalFlo

This section describes how to operate the ThermalFlo heat pump.

Initial Start-up Precautions

CAUTION — Do not use this heat pump if any part has been under water. Immediately call a qualified service technician to inspect the heater and replace any part of the control system which has been under water.

CAUTION — Keep all objects off the top of the heat pump. Blocking air flow could damage the unit and may void the warranty.

ATTENTION

After starting the ThermalFlo heat pump, please note that there is a 5 minute delay before the compressor begins operation. The heat pump display will show the remaining delay time in minutes and hundredths of a minute.

Be sure that there is water in the pool and that the surface level is above the skimmer or other inlets of the pool’s filter system.

The pool pump must be on and water flowing through the heat pump for it to operate.

With any new pool or spa installation, operate the filter pump with the heat pump off long enough to completely clean the water. This will remove any installation residue from the water. Clean the filter at the end of this operation before starting the heat pump. When raising the temperature of a cold pool, program the time clock to run the pump continuously. This lets the filter system and heat pump operate continuously until the water reaches the temperature setting on the temperature control. When that happens, the heat pump will automatically shut off, but the filter pump will keep running.

Figure 14.

ThermalFlo Installation and User’s Guide

Image 23
Contents ThermalFlo Web site Customer ServiceContents Illustrated Parts Replacement Parts List Codes and Standards Important NoticeConsumer Information and Safety Important Safety PrecautionsSwimming Pool Energy Saving Tips Warranty Information General Installation InformationGeneral Specifications ThermalFlo Overview Section IntroductionGeneral Features Materials needed for Installation Section InstallationInstalling the ThermalFlo Location ThermalFlo Heat Pump DimensionsEquipment Pad ClearancesRoof Run-off Lawn Sprinklers Anchor Clamps InstallationDrainage and Condensation Plumbing layout Water ConnectionsAutomatic Flow Control Valve Check Valve InstallationWater Connections at the Heat Pump Heat Pump, Heater and/or Solar Combination Multiple Unit InstallationTo Pool Multiple Heat Pump ConnectionsBonding Main PowerElectrical Connections General Information460812, 460813, 460814, 460815, 460822 Wiring DiagramHeat Pump Control Board Relay Remote ControlsBLK GRN YEL RED Section Operating ThermalFlo Initial Start-up PrecautionsWater Pressure Thermostat Heating Cooling Operating the ControllerMode Indicator LEDs Indicator Lights / LEDsSystem Indicator LEDs Keypad Lockout Temperature SettingMode Selection Buttons OperationCode Name Cause TroubleshootingWater Pressure Switch Adjustment Winterizing Section General MaintenanceWater Chemistry Owner Inspection Inspection and ServiceSpring Start-Up AIR Professional Maintenance and ServiceThermalFlo Installation and User’s Guide Remote, Pool or Spa light on Section TroubleshootingDealer for advice. Call the factory for advice Pressure Illustrated Parts Section Replacement Parts25 473026 Compressor Isolation KIT, Grommet & Spacer 1 SET Replacement Parts ListThermalFlo Installation and User’s Guide Page 473426 Rev. C 10/19/06

ThermalFlo specifications

Pentair ThermalFlo is a leading-edge solution designed to address the evolving demands of thermal management in various industrial applications. As organizations prioritize energy efficiency and temperature regulation, ThermalFlo emerges as a robust offering from Pentair, a global leader in water and fluid management.

One of the standout features of Pentair ThermalFlo is its innovative heat tracing technology. This system employs electrical heat tracing cables that are strategically engineered to maintain desired temperatures in pipes, valves, and other critical components. The design minimizes the risks of freezing, ensuring that fluids can flow seamlessly, even in harsh environments. Moreover, it enhances safety by reducing the likelihood of pipe bursts due to thermal stress.

ThermalFlo also incorporates advanced insulation technologies that complement its heat tracing capabilities. The combination of these two approaches ensures optimal energy efficiency, reducing heat loss and lowering operational costs. When used in conjunction with smart monitoring systems, organizations can achieve real-time temperature control, allowing for proactive adjustments that enhance system efficiency.

Another significant characteristic of Pentair ThermalFlo is its versatility. This solution can be customized to suit various applications, from oil and gas industries to food processing and pharmaceuticals. The adaptability of ThermalFlo makes it an ideal choice for facilities looking to improve their thermal strategies without compromising on performance.

In addition to its technical features, Pentair ThermalFlo emphasizes sustainability. By promoting energy efficiency and reducing heat loss, the system contributes to lower carbon footprints for its users. This aligns with the growing trend of adopting environmentally responsible practices within industry, showcasing Pentair’s commitment to innovative solutions that meet modern challenges.

Furthermore, the installation and maintenance of ThermalFlo systems are streamlined, with user-friendly features that simplify the process for engineers and technicians. Its robust design ensures long-lasting performance, reducing downtime and maintenance costs over time.

In conclusion, Pentair ThermalFlo stands out in the marketplace through its blend of innovative technologies, energy efficiency, and adaptability across different industries. As businesses increasingly seek effective thermal management solutions, ThermalFlo represents an investment in reliability, safety, and sustainability.