Leica ASP300 instruction manual Switching the instrument on, Setting up the instrument

Page 24
4.6 Switching the instrument on

4.Setting up the instrument

4.6 Switching the instrument on

Once the instrument has been switched on, the mains switch (ON/OFF) (5) should always re- main in position ON.

• After switching it on the instrument will take a few minutes to initialize (see opposite - Fig. 7).

• After initialization, the FAVORITES screen will be displayed (Fig. 8).

Screen saver

Fig. 7

• A screen saver will operate turning the

 

 

screen off when no key has been pressed

 

for a (user-) programmable time.

 

Press any part of the touchscreen to restore

 

the screen.

 

After having been restored, the screen will

 

be inoperational for a few seconds to avoid

 

accidental activation of any key symbols.

 

.

Fig. 8

24

Instruction Manual V 1.3 – 12/2003

Image 24
Contents Automated vacuum tissue processor Leica ASP300Advanced Smart Processor Page Published by Table of contents Table of contents Trouble shootingCleaning and maintenance 7.3.1 Daily cleaning and maintenance1.1Symbols used in this manual and their meaning 1.Important notes1.2 Designated use Chapter 3.5 - “Compatible reagents“2. Safety 2.1 Safety instructions2.Safety 2.2 Warnings2. Safety Warnings - cleaning and maintenanceWarnings - working with the instrument 2.3 Integrated safety devices Overpressure protectionProtection against excessive vacuum Overcurrent protection3.Instrument components and specifications 3.1Specific instrument options3.2 Overview - instrument components 3.Instrument components and specificationsInstrument components and accessories Overview - Instrument components3.Instrument components and specifications 3.3 Standard delivery - packing list 3.Instrument components and specificationsInstrument components and specifications 3.4 Technical data3.Instrument components and specifications Retort3.4 Technical Data continued 3.Instrument components and specifications3.5 Compatible reagents 3.Instrument components and specifications4. Setting up the instrument 4.2Electrical connection4.1 Site requirements Moving the instrumentConnecting the instrument to mains 4. Setting up the instrument4.Setting up the instrument 4.3 Installing the accessories4.4 Setting up the data connections 4.Setting up the instrumentPrinter optional Lift off the instrument console flap4.5 Alarm functions 4. Setting up the instrument4.6 Switching the instrument on 4.Setting up the instrument4.Setting up the instrument 2 - Access INSTALLATION menu4.Setting up the instrument Button symbols4.7.2. Access control 4.Setting up the instrument→→ →→ →→ →→ → → → → →→→ →→4.Setting up the instrument 5. Operation 5.1 Reagent handling5.1.1Fill/drain reagents other than wax 5.Operation Fill / drain reagents →5.1.2 Changing the wax → + →5.Operation Filling with wax pellets → → 5.OperationAdding molten paraffin 5. Operation5.2 Setting up the instrument parameters → 5.2.1 System setup5.Operation 5. Operation Program Options5.Operation Security5.2.2 Editing the reagent list 5. Operation5. Operation Entering / modifying reagent thresholds↓ ↓ ↓ 5.Operation5.2.3Viewing the program list 5.Operation5.2.4 Adding and/or modifying programs 5. Operation5.Operation 5. Operation Editing program steps continued5.2.5Favorites maximum of 5 programs 5.Operation5.Operation 5.2.6 Editing the stations 5.Operation5. Operation 5.3 Programs 5.Operation5.3.1 Editing a selected program EDIT to access the Edit Program screenEnter the day when you want the program finished 5. OperationLEVEL CHECK enabled 5.Operation5.3.2 Starting a program 5. Operation5.4Reagent status → 5.Operation5.5 System Monitor → → 5. Operation5.6 On-linehelp 5.Operation5.7Configuring a printer optional →→ 5.Operation6.Trouble shooting → 6.2 Power failure6.1 General 6.Trouble shooting 6.3Trouble shooting →6.4 Typical fill or drain problems 6.Trouble shooting7.Cleaning and maintenance 7.1Clean programs →→ 7.1.1 Retort clean programsEditing steps 7.Cleaning and maintenance7. Cleaning and maintenance 7.1.2 Wax clean programs7.1.3Smart clean → 7.Cleaning and maintenance7.2 General cleaning steps 7. Cleaning and maintenance7.Cleaning and maintenance Draining the condensate bottleExchanging the activated carbon filter Exchange the filter as shown in Fig7.3.1Daily cleaning and maintenance 7. Cleaning and maintenance7.3.2Periodic cleaning and maintenance 7.Cleaning and maintenance7.4 Preventative maintenance schedule 7. Cleaning and maintenance7. Cleaning and maintenance Maintenance activity8. Warranty and service WarrantyTechnical service information Decommissioning and disposal