B. Clearances to Combustibles (UL and ULC)
NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction
BACKWALL / SIDEWALL
A | B |
| C |
| D |
CORNER INSTALLATION
E | F |
| |
| E |
| F |
90° OFF TOP
UP & OUT CEILING CLEARANCE
STOVE TO CEILING CLEARANCE
H
G
ALCOVE SIDE VIEW
G |
A |
B |
ALCOVE TOP VIEW
C
D
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: Inches & (Millimeters)
NOTE: All “A”, “C” and “F” dimensions are to inside diameter of flue collar.
| A | B |
| C | D | E |
| F | G | H |
INSTALLATION: Full Vertical OR Horizontal with 2 foot (609mm) minimum vertical Off Stove Top | ||||||||||
SINGLE WALL PIPE | 10 (254) 8.25 (210) 21 | (533) | 11 (279) 3.5 (89)12.5 | (318) | 49 (1245) | * | ||||
DOUBLE WALL PIPE | 9 (229) 7 (178) | 19.5 (495) | 9 (229) | 3 (76) | 12 (305) | 49 (1245) | 10 (254) | |||
INSTALLATION: 90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL |
|
|
| |||||||
SINGLE WALL PIPE | 9.25 (235) 7.5 | (191) | 18 | (457) | 8 (203) | 3.5 (89)12.5 | (318) | 49 (1245) | * | |
DOUBLE WALL PIPE | 9.25 (235) 7.5 | (191) | 18 | (457) | 8 (203) | 3 (76) | 12 (305) | 49 (1245) | 10 (254) |
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Single Wall or Double Wall air insulated connector pipe with UL103 HT** Listed
**In Canada must comply with Standard
* SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
WARNING! Risk of Fire!
•Comply with all minimum clearanes to combustibles as specified.
•Failure to comply may cause house fire.
NOTE: Service Space
In order to replace the tube channel assembly a clearance of 19 inches (483mm) is required on the right side of stove in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon- nected from the chimney to proceed with the tube replace- ment.