Heatiator ECO-ADV-WS22 Listing and Code Approvals, A. Appliance Certification, Model, Laboratory

Page 6
1 Listing and Code Approvals

1 Listing and Code Approvals

A. Appliance Certification

Model:

ECO-ADV-WS22 Wood Stove

Laboratory:

Intertek

Report Number:

3198460

Type:

Listed Room Heater, Solid Fuel Type

Standard:

UL1482 and ULC S627-00 and

 

(UM) 84-HUD, Mobile Home

 

Approved.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the UL1482, (UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-00 and CAN/CSA-B365 Installation Codes in Canada.

D. BTU & Efficiency Specifications

EPA Certified:

2.7 grams per hour

Efficiency:

82.3%

BTU Output:

11,700 to 27,000 per hour

Heating Capacity:

1,580 to 2,780 sq. feet

 

depending on climate zone

Vent Size:

6 inches

Firebox Size:

2.75 cubic feet

Max Wood Length:

22 inches

Fuel:

Cord Wood

Shipping Weight:

410 lbs

WARNING! Risk of Fire! Hearth & Home Technologies dis- claims any responsibility for, and the warranty and agency listing will be voided by the below actions.

The ECO-CHOICE by Heatilator wood stove meets the U.S. Environmental Protection Agency’s 1990 particulate emis- sion standards.

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an out- side combustion air inlet is provided.

The structural integrity of the mobile home floor, ceiling, and walls must be maintained.

The appliance must be properly grounded to the frame of the mobile home with #8 copper ground wire, and use only listed double-wall connector pipe.

Outside Air Kit, part OAK-ACC must be installed in a mo- bile home installation.

C. Glass Specifications

This stove is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

DO NOT:

Install or operate damaged appliance

Modify appliance

Install other than as instructed by Hearth & Home Technologies

Operate the appliance without fully assembling all components

Overfire

Install any component not approved by Hearth & Home Technologies

Install parts or components not Listed or approved

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

For assistance or additional information, consult a qualified installer, service agency or your dealer.

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.

Heatilator is a registered trademark of Hearth & Home Technologies.

6

Heatilator • ECO-ADV-WS227057-128C • August 13, 2010

Image 6
Contents DO DIS NOT C AR D WS22Model ECO-ADV-WS22 Wood Burning Stove LOCATION Back of Appliance SAMPLE OF SERIAL NUMBER / SAFETY LABELCongratulations Test Lab andSafety Alert Key TABLE OF CONTENTSInstaller’s Guide User’s GuideWARRANTY COVERAGE Warranty PolicyHEATILATOR ECO-CHOICEWARRANTY WARRANTY PERIODWARRANTY COVERAGE WARRANTY EXCLUSIONSThis warranty is void if WARRANTY EXCLUSIONS1 Listing and Code Approvals D. BTU & Efficiency SpecificationsC. Glass Specifications A. Appliance CertificationA. Your Wood Appliance - General Operating Parts User Guide2 Operating Instructions Hot glass will cause burnsC. Overfiring B. Fire SafetyD. Combustible/Non-combustibleMaterials E. Seasoned Wood2. Second Stage G. Burning Process1. Kindling or First Stage 3. Final StageFigure 10.1 - Burn Rate Air Control H.Burn Rate Air ControlI. Burn Rates and Operating Efficiency For maximum operating efficiencyBack of Firebox J. Correct Baffle & Blanket PlacementCeramic Blanket Baffle BoardK. Building A Fire Do NOTSoft woods L.Wood FuelWARNING! Risk of Fire Hard woodsFigure 14.2 - Snap Disc Location M. Blower Operating InstructionsN. Clear Space 7.Snap Disc LocationSOLUTIONS P. Frequently Asked QuestionsISSUES O. Opacity SmokeLOAD WOOD The stove is ready for normal operationQ. Quick Start Guide ADD NEWSPAPERC. Appliance Inspection - Routine 3 Maintenance and ServiceA. Disposal of Ashes WARNING! Risk of FireD. Glass Cleaning E. Firebrick InspectionFrequency As desired F. Quick Reference Maintenance Guide Solution 4 Troubleshooting GuideStart Fire Problems Possible CauseB. Snap Disc Replacement 5 Service Parts ReplacementA. Glass Replacement WARNING! Risk of Fire or InjuryC.Baffle Removal Figure Figure 22.1 - BaffleD. Door Handle Assembly Replacing Tube Channel Assembly E. Tube Channel Assembly ReplacementRemoving Tube Channel Assembly NOTE Service Space6 Getting Started Installer’s GuideA. Design and Installation Considerations B. DraftD. Locating Your Stove & Chimney E. Chimney Termination RequirementsF. 2-10-3Rule Flat RoofI.Inspect Appliance and Components H. Fire SafetyG. Tools And Supplies Needed WARNING! Risk of FireFigure 29.1 - Front View 7 Dimensions and ClearancesA. Appliance Dimensions Figure 29.2 -TopViewB. Clearances to Combustibles UL and ULC SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTEDFLOOR PROTECTION C. Hearth Protection RequirementsCANADA See FigureConverting k to R Thermal Conductivity k valueThermal Resistance R value Converting R to kB. Inspections 8 Venting and Chimney SystemsA. Venting Systems C. Larger ChimneysS629M, STANDARD FOR 650oC FACTORY-BUILTCHIMNEYS E. Chimney Height / Rise and RunF.Factory-BuiltChimney WARNING! Risk of FireG. Masonry Chimney H. Masonry Chimney Liner Solid Pack Chimney with Metal Supports I.Air ClearancesJ. Thimble as a ThimbleWARNING! Risk of Fire as a Thimble Cont’dSolid Pack Chimney with Metal Supports Heatilator ECO-ADV-WS22 7057-128C AugustItems Needed for Installation not supplied A. Outside Air Kit Installation9 Appliance Set-up Figure 39.2 - Alternate Floor InstallationB. Mobile Home Installation WARNING! Risk of AsphyxiationC. Blower Installation Optional D. Adjusting the Blower Speed ControlCAUTION! Risk of Shock Reference Materials 13 Inlet Assembly14 Door Assembly A. Exploded ViewHOW TO ORDER Brick AssemblyB. Service Parts & Accessories DESCRIPTIONAccessories B. Service Parts & Accessories Cont’dHOW TO ORDER DESCRIPTIONDescription of Service C. Service And Maintenance LogDate of Service Performed ByDescription of Service C. Service And Maintenance Log Cont’dDate of Service Performed ByD.Homeowner’s Notes Heatilator ECO-ADV-WS22 7057-128C AugustColville, WA Division of HNI INDUSTRIES E. Contact InformationHearth & Home Technologies 1445 North Highway DO DIS NOT C AR D