Heath Zenith UT-9260-WH Finish Mounting, Specifications, CAUTION: To Avoid Fire Or Burn Hazards

Page 8
Finish Mounting

Finish Mounting

Align the cover plate, gasket, and the mounting bracket hole. Secure with M5 x 0.8 x 40 mm mounting screw supplied.

Push the rubber plug firmly into place.

If not installed on a weatherproof box, caulk between the cover plate and mounting sur- face with silicone weather sealant.

To obtain maximum lamp life, keep the tubular lamps horizontal.

Rubber Plug

Specifications

Range

70 feet (21.0 m); 100 feet

 

(30.5 m) with Range Boost.

 

Varies with surrounding

 

temperature.

Sensing Angle

Up to 270° (Adjustable)

Fixture Load

Up to 500 Watts Maximum

 

Tungsten Incandescent [Up

 

to 250 Watts Maximum each

 

lamp holder.]

Sensor Load Capacity

Up to 1000 Watts (8.3 amps)

 

Maximum Tungsten Incan-

 

descent

Power Requirements

120 VAC, 60 Hz

Operating Modes

TEST,AUTO and MANUAL

 

MODE

Time Delay

1, 5, 20 minutes

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

CAUTION: To Avoid Fire Or Burn Hazards:

Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.

Keep fixture at least 3" (76 mm) from combustible materials. Do not aim at objects closer than 3' (1 m).

Use only type T 250W (max.) tungsten halogen 120 VAC lamps.

- -

598-1291-02

Image 8
Contents Motion Sensing Halogen Security Light 182148UT-9260-BZ 182149Contents Introduction Enhanced Performance FeaturesPackage Contents Fits All Junction Box ConfigurationsInstallation Wall MountEave Mount circuit breakerStandard Wiring Mount Fixture with Crossbar Mounting BracketCircular or Octagonal Junction Box - Use Watertight Junction Box - Use two #10-24Wiring to a Motion Light & Standard Fixture Controlling Non-MotionSensing FixturesCAUTION: To Avoid Fire Or Burn Hazards SpecificationsFinish Mounting Sensor Bottom Do not aim the sensor at Test and AdjustmentTurn on the circuit breaker and light switch Most Sensitive Adjustments ContinuedExpected Coverage If the wide angle 270 coverage is too wide for Without Lens ShieldOperation TestManual TESTTroubleshooting Guide Technical ServiceSYMPTOM SYMPTOMLifetime Warranty 182148 UT-9260-BZ182149 UT-9260-WHIndice Introducción Características Mejoradas de RendimientoQueda bien con todas las configuraciones de cajas de empalmesContenidos del Paquete Instalación Montaje en paredMontaje en alero cortacircuitosInstale el aparato con el soporte de montaje de la barra de cruceCableado Estándar Caja de Empalme Circular o RectangularNEGRO del interruptor al NEGRO de la lámparade seguridad al NEGRO del artefacto de luzFin del Montaje EspecificacionesPrueba y Ajuste Prenda el cortacircuitos y el interruptor de luzFondo del Detector Evite apuntar el detector haciaLo menos sensible Continuación de ajustesCobertura Esperada Angulo de Cobertura Máxima Sin protector de placa translúcidaFuncionamiento PRUEBAAUTOM MODOGuia de Investigacion de Averias Servicio TécnicoGarantía ilimitada Luminaire De Sécurité À Halogène Avec Détecteur De Mouvement182148 UT-9260-BZ 182149 UT-9260-WH Articles ModèlesTable des matières Caractéristiques de performance améliorées IntroductionContenu de l’emballage Convient à tous les types de boîte de jonctionInstallation Montage muralMontage sous avant-toit au disjoncteurCâblage standard au fusible ou au disjoncteurFil NOIR de l’interrupteur avec le fil NOIR du luminaire de sécuritéStandard BLANC de la ligne à BLANC du luminaireFinir le montage SpécificationsNe pointez pas le détecteur en direction Test et réglageDessous du détecteur MouvementMouvement Détecteur Moins sensiblePortée maximale Détecteur presque parallèle au solAngle de couverture maximum Sans volet Volet complètement sorti270 3535 Volet complètement rentréFonctionnement TESTAUTO PRIORITÉ MANUELLEService Technique Guide de dépannageGarantie à vie