Finish Mounting
❒Align the cover plate, gasket, and the mounting bracket hole. Secure with M5 x 0.8 x 40 mm mounting screw supplied.
❒Push the rubber plug firmly into place.
❒If not installed on a weatherproof box, caulk between the cover plate and mounting sur- face with silicone weather sealant.
To obtain maximum lamp life, keep the tubular lamps horizontal.
Rubber Plug
Specifications | |
Range | 70 feet (21.0 m); 100 feet |
| (30.5 m) with Range Boost. |
| Varies with surrounding |
| temperature. |
Sensing Angle | Up to 270° (Adjustable) |
Fixture Load | Up to 500 Watts Maximum |
| Tungsten Incandescent [Up |
| to 250 Watts Maximum each |
| lamp holder.] |
Sensor Load Capacity | Up to 1000 Watts (8.3 amps) |
| Maximum Tungsten Incan- |
| descent |
Power Requirements | 120 VAC, 60 Hz |
Operating Modes | TEST,AUTO and MANUAL |
| MODE |
Time Delay | 1, 5, 20 minutes |
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
CAUTION: To Avoid Fire Or Burn Hazards:
•Allow fixture to cool before touching. The bulb and the fixture operate at high temperatures.
•Keep fixture at least 3" (76 mm) from combustible materials. Do not aim at objects closer than 3' (1 m).
•Use only type T 250W (max.) tungsten halogen 120 VAC lamps.
- - |