Black & Decker MUZ-FD12NA- U1, MUZ-FD09NA- U1 service manual Test condition, Operating Range

Page 5

Test condition

3,

4

 

 

 

 

 

 

ARI

Mode

Test

 

Indoor air condition

Outdoor air condition

 

Dry bulb (°F)

Wet bulb (°F)

Dry bulb (°F)

Wet bulb (°F)

 

 

 

 

 

 

 

 

 

"A" Cooling Steady State

 

80

67

95

(75)

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

"B-2" Cooling Steady State

 

80

67

82

(65)

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

SEER

"B-1" Cooling Steady State

 

80

67

82

(65)

 

(Cooling)

at minimum compressor Speed

 

 

 

 

 

 

 

 

 

Low ambient Cooling Steady State

 

80

67

67

(53.5)

 

 

at minimum compressor Speed

 

 

 

 

 

 

 

 

 

 

Intermediate Cooling Steady State

 

80

67

87

(69)

 

 

at Intermediate compressor Speed

5

 

 

 

 

 

 

 

 

Standard Rating-Heating

 

70

60

47

43

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

Low temperature Heating

 

70

60

17

15

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

Max temperature Heating

 

70

60

62

56.5

 

HSPF

at minimum compressor Speed

 

 

 

 

 

 

 

 

(Heating)

High temperature Heating

 

70

60

47

43

 

 

at minimum compressor Speed

 

 

 

 

 

 

 

 

 

 

Frost Accumulation

 

70

60

35

33

 

 

at rated compressor Speed

 

 

 

 

 

 

 

 

 

 

Frost Accumulation

 

70

60

35

33

 

 

at Intermediate compressor Speed

5

 

 

 

 

 

 

5 : At Intermediate compressor Speed

=("Cooling rated compressor speed" - "minimum compressor speed") / 3 + "minimum compressor speed".

OPERATING RANGE

(1) POWER SUPPLY

 

Rated voltage

 

Guaranteed Voltage

 

 

 

 

 

 

 

 

208/230 V

Min.187 V 208 V 230 V Max.253 V

Outdoor unit

1 phase

 

 

 

 

 

 

 

 

 

 

 

60 Hz

 

 

 

 

 

 

 

 

 

 

 

 

(2) OPERATION

Mode

Condition

 

 

Intake air temperature (°F)

 

 

lndoor

 

 

Outdoor

 

 

DB

 

WB

DB

 

WB

 

Standard temperature

80

 

67

95

 

Cooling

Maximum temperature

90

 

73

115

 

Minimum temperature

67

 

57

14

 

 

 

 

 

Maximum humidity

78

%

 

 

Heating

Standard temperature

70

 

60

47

 

43

Maximum temperature

80

 

67

75

 

65

 

Minimum temperature

70

 

60

14

 

13

5

Image 5
Contents MUZ-FD09NA MUZ-FD09NA- U1 MUZ-FD12NA MUZ-FD12NA- U1 Page Part Names and Functions Technical ChangesMUZ-FD09NA MUZ-FD12NA SpecificationOperating Range Test conditionRequired Space Outlines and DimensionsWiring Diagram MAX. Refrigerant Piping Length and MAX. Height Difference Refrigerant System DiagramData MUZ-FD09NA MUZ-FD12NA Performance Curve CoolingHeating MUZ-FD09NACondensing pressure Condensing Pressure Cooling65 70F MSZ-FD09NA MSZ-FD12NA Standard Operation DataCorrection of Heating capacity Test RUN Operation How to operate fixed-frequency operationOutdoor FAN Motor Control Actuator ControlR.V. Coil Control Relation Between Main Sensor and ActuatorTroubleshooting Service FunctionsChange in Defrost Setting PRE-HEAT Control SettingOFF Failure Mode Recall FunctionOperational procedure Outdoor unit failure mode table Troubleshooting Check Table Page WHT RED Trouble Criterion of Main Parts MUZ-FD09NAMUZ-FD12NACheck of open phase How to check inverter/ compressorTroubleshooting Flow Check of compressorCheck of compressor start failure Check of compressor windingCheck of compressor operation time Unit operates Heat mode even if it is set to Cool mode Unit operates Cool mode even if it is set to Heat modeCheck of outdoor thermistors Check of R.V. coilCheck of outdoor fan motor Check of power supplyCheck of LEV Expansion valve Emergency Operation Check of inverter P.C. boardPage Outdoor unit Electromagnetic noise enters into TV sets or radiosInverter P.C. board Test Point Diagram and VoltageRemoving the cabinet Photo Disassembly InstructionsPhoto 4 inverter assembly Removing the inverter assembly, inverter P.C. board PhotoPhoto Removing the discharge temperature thermistor Removing R.V. coilRemoving the compressor and 4-way valve Removing outdoor fan motor PhotoPage New publication, effective Jan