Black & Decker MUZ-FD09NA- U1 Trouble Criterion of Main Parts MUZ-FD09NAMUZ-FD12NA, Wht Red

Page 22

10-4. TROUBLE CRITERION OF MAIN PARTS MUZ-FD09NAMUZ-FD12NA

Part name

 

Check method and criterion

 

 

 

 

 

 

 

Figure

Defrost thermistor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(RT61)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature

Measure the resistance with a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor (RT65)

Refer to 10-6. “Test point diagram and voltage”,1. “Inverter P.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor heat ex-

board”, the chart of thermistor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

changer temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor (RT68)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge tem-

Measure the resistance with a tester. Before measurement, hold the

 

 

 

 

 

 

 

 

 

 

 

 

 

perature thermistor

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor with your hands to warm it up.

 

 

 

 

 

 

 

 

 

 

 

 

 

(RT62)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fin temperature

Refer to 10-6. “Test point diagram and voltage”,1. “Inverter P.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

board”, the chart of thermistor.

 

 

 

 

 

 

 

 

 

 

 

 

 

thermistor (RT64)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance between terminals using a tester.

WHT

RED BLK

 

(Winding temperature : -4 ~ 104 °F (-20 ~ 40 °C))

 

 

 

 

 

 

 

2

 

 

 

3

 

 

1

Compressor

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U-V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U-W

 

1.52 ~ 2.17 Ω

 

 

V

 

 

 

 

U

 

 

 

 

 

V-W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance between lead wires using a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Part temperature : 14 ~ 104 °F (-10 ~ 40 °C))

WHT

RED BLK

 

 

 

 

 

 

 

2

 

 

3

 

 

 

 

1

 

Outdoor fan motor

 

Color of lead wire

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED – BLK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK – WHT

 

11 ~ 16 Ω

 

 

V

 

 

 

U

 

 

 

 

 

WHT – RED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance using a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Part temperature : 14 ~ 104 °F (-10 ~ 40 °C))

 

 

 

 

 

 

 

 

 

 

 

 

 

R. V. coil (21S4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

970 ~ 1380 Ω

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measure the resistance using a tester.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Part temperature : 14 ~ 104 °F (-10 ~ 40 °C))

WHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

LEV

Expansion valve coil

 

Color of lead wire

 

Normal

 

ORN

 

 

 

 

 

 

 

 

 

 

WHT – RED

 

 

 

 

 

 

 

 

 

 

 

 

(LEV)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RED – ORN

 

37 ~ 54 Ω

 

 

 

 

 

 

YLW

 

 

 

BRN

 

 

BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YLW – BRN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRN – BLU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Image 22
Contents MUZ-FD09NA MUZ-FD09NA- U1 MUZ-FD12NA MUZ-FD12NA- U1 Page Technical Changes Part Names and FunctionsSpecification MUZ-FD09NA MUZ-FD12NATest condition Operating RangeOutlines and Dimensions Required SpaceWiring Diagram Refrigerant System Diagram MAX. Refrigerant Piping Length and MAX. Height DifferenceData Heating Performance Curve CoolingMUZ-FD09NA MUZ-FD12NA MUZ-FD09NACondensing Pressure Cooling Condensing pressure65 70F Standard Operation Data MSZ-FD09NA MSZ-FD12NATest RUN Operation How to operate fixed-frequency operation Correction of Heating capacityR.V. Coil Control Actuator ControlOutdoor FAN Motor Control Relation Between Main Sensor and ActuatorChange in Defrost Setting Service FunctionsTroubleshooting PRE-HEAT Control SettingFailure Mode Recall Function OFFOperational procedure Outdoor unit failure mode table Troubleshooting Check Table Page Trouble Criterion of Main Parts MUZ-FD09NAMUZ-FD12NA WHT REDTroubleshooting Flow How to check inverter/ compressorCheck of open phase Check of compressorCheck of compressor operation time Check of compressor windingCheck of compressor start failure Check of outdoor thermistors Unit operates Cool mode even if it is set to Heat modeUnit operates Heat mode even if it is set to Cool mode Check of R.V. coilCheck of power supply Check of outdoor fan motorCheck of LEV Expansion valve Check of inverter P.C. board Emergency OperationPage Electromagnetic noise enters into TV sets or radios Outdoor unitTest Point Diagram and Voltage Inverter P.C. boardDisassembly Instructions Removing the cabinet PhotoPhoto Removing the discharge temperature thermistor Removing the inverter assembly, inverter P.C. board PhotoPhoto 4 inverter assembly Removing R.V. coilRemoving outdoor fan motor Photo Removing the compressor and 4-way valvePage New publication, effective Jan