Pelco IS210 manual Removing the Conduit Cover

Page 11

CONDUIT COVER

HEX HEAD INSET

SCREW

1/16-INCH HEX HEAD WRENCH

Figure 7. Removing the Conduit Cover

6.Install a 0.75-inch (1.91 cm) conduit connector in the conduit opening. Line up the mounting holes in the base with the mounting holes of the mounting plate. Attach the base to the mounting plate with the three 8-32 x 0.375-inch screws and washers previously removed.

7.Attach the base to the conduit and then connect the power input wires to the power wires of the IS210 Camclosure. Refer to the following to connect the power wires:

Table B. Power Input

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

8.Connect the video cable/wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Connect the blue wire to Video +; connect the gray wire to Video -.

C3428M-A (1/08)

11

Image 11
Contents IS210 Series Camclosure Page Contents Important Safety Instructions Radio and Television Interference Regulatory NoticesDescription Parts ListPrepare Mounting Surface InstallationFixed Mounting Pattern With Conduit Install BaseWithout Conduit Removing the Wiring Plug Removing the Conduit Cover Replace Cover Reinstall Camera ModuleAdjust Position SW4-2 Backlight Compensation DN/CH Series AdjustmentsSwitch Settings SW4-1 Automatic Gain ControlSW4-5 Auto White Balance/Manual White Balance Auto Iris Level AdjustmentVertical Phase Adjustment SW4-4 FlickerlessBlemish Detection Adjusting Vertical PhaseDAY/NIGHT Operation SW1-3 Interlaced Scanning/Progressive Scanning DW/CW Series Wide Dynamic Range AdjustmentsSW1-1 Video Format SW1-2 Line SyncSW1-7 Digital Slow Shutter SW1-4 Auto White Balance/Manual White BalanceSW1-5 Fluorescent/General SW1-6 General WDR/Maximum WDRSW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Attaching the 2.5 mm Monaural Headphone Plug Service ConnectorGeneral SpecificationsProduct Warranty and Return Information ISO9001