PREPARE MOUNTING SURFACE

1.Remove the cover of the IS210. Use the screwdriver bit (supplied) to loosen the three tamperproof screws, and then lift the cover from the base.

2.Remove the camera assembly from the base by removing the Phillips screws on each side of the camera assembly (refer to Figure 2).

CAMERA ASSEMBLY

PHILLIPS

SCREW

Figure 2. Removing Camera Module

3.Remove the base from the mounting plate by removing the three 8-32 x 0.375-inch screws and washers. Lift the base from the mounting plate and set aside the base, screws, and washers.

4.Select a fixed or adjustable mounting pattern (refer to Figure 3 and Figure 4 on page 8). Using the mounting plate as a template, mark the wire feedthrough and fastener hole positions on the mounting surface. Prepare the holes for the installation.

C3428M-A (1/08)

7

Image 7
Contents IS210 Series Camclosure Page Contents Important Safety Instructions Radio and Television Interference Regulatory NoticesDescription Parts ListPrepare Mounting Surface InstallationFixed Mounting Pattern Without Conduit Install BaseWith Conduit Removing the Wiring Plug Removing the Conduit Cover Adjust Position Reinstall Camera ModuleReplace Cover SW4-2 Backlight Compensation DN/CH Series AdjustmentsSwitch Settings SW4-1 Automatic Gain ControlSW4-5 Auto White Balance/Manual White Balance Auto Iris Level AdjustmentVertical Phase Adjustment SW4-4 FlickerlessBlemish Detection Adjusting Vertical PhaseDAY/NIGHT Operation SW1-3 Interlaced Scanning/Progressive Scanning DW/CW Series Wide Dynamic Range AdjustmentsSW1-1 Video Format SW1-2 Line SyncSW1-7 Digital Slow Shutter SW1-4 Auto White Balance/Manual White BalanceSW1-5 Fluorescent/General SW1-6 General WDR/Maximum WDRSW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Attaching the 2.5 mm Monaural Headphone Plug Service ConnectorGeneral SpecificationsProduct Warranty and Return Information ISO9001