Pelco IS210 manual Auto Iris Level Adjustment

Page 20

AUTO IRIS LEVEL ADJUSTMENT

The electronics of the IS210-DW and IS210-CW Series Camclosures automatically adjust the camera to the auto iris. Auto iris level adjustments are not necessary.

VERTICAL PHASE ADJUSTMENT

NOTE: Use this procedure for 24 VAC operation only.

When using more than one camera power supply, a brief vertical roll may occur on the monitor when switching from one camera to another.

To eliminate vertical roll, reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem. If the problem continues, adjust the phase control by synchronizing, or line locking, the cameras to one another.

NOTE: When adjusting vertical phase, line sync (SW1-2) must be set to ON for AC line lock.

Adjusting Vertical Phase

You may need two people when synchronizing the cameras: one at the camera, the other at the monitor to observe the vertical roll and the effect of any camera adjustments.

To synchronize the cameras:

1.Choose a reference camera to which all other cameras will be phased.

2.Select the camera to synchronize. Use the phase adjustment control (R7) to synchronize the camera to the reference camera (refer to Figure 12 on page 17). Turn R7 clockwise to increase vertical phase; turn R7 counterclockwise to decrease vertical phase.

3.Each time an adjustment is made, switch back and forth between the camera you are adjusting and the reference camera. Repeat this process as many times as necessary until the roll between the cameras is no longer noticeable.

4.Adjust the phase of all other cameras by repeating steps 2 and 3. Always adjust to the reference camera selected in step 1.

NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope to align the vertical sync pulses of the reference camera to the selected camera(s).

BLEMISH DETECTION

If small white or colored spots appear in the video image, one or more pixels on the camera imager may be defective. (This condition is common for both CCD and CMOS imagers.)

DW and CW Series cameras have auto iris lenses and automatically detect and correct defective pixels during startup. Manual pixel correction is not available.

20

C3428M-A (1/08)

Image 20
Contents IS210 Series Camclosure Page Contents Important Safety Instructions Regulatory Notices Radio and Television InterferenceParts List DescriptionInstallation Prepare Mounting SurfaceFixed Mounting Pattern With Conduit Install BaseWithout Conduit Removing the Wiring Plug Removing the Conduit Cover Replace Cover Reinstall Camera ModuleAdjust Position DN/CH Series Adjustments Switch SettingsSW4-1 Automatic Gain Control SW4-2 Backlight CompensationAuto Iris Level Adjustment Vertical Phase AdjustmentSW4-4 Flickerless SW4-5 Auto White Balance/Manual White BalanceAdjusting Vertical Phase Blemish DetectionDAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-1 Video FormatSW1-2 Line Sync SW1-3 Interlaced Scanning/Progressive ScanningSW1-4 Auto White Balance/Manual White Balance SW1-5 Fluorescent/GeneralSW1-6 General WDR/Maximum WDR SW1-7 Digital Slow ShutterSW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Service Connector Attaching the 2.5 mm Monaural Headphone PlugSpecifications GeneralProduct Warranty and Return Information ISO9001