Page 15

Adjusting Vertical Phase

You may need two people when synchronizing the cameras: one at the camera, the other at the monitor to observe the vertical roll and the effect of any camera adjustments.

To synchronize the cameras:

1.Choose a reference camera to which all other cameras will be phased.

2.Select the camera to synchronize. Use buttons SW1 and SW2 to synchronize the camera to the reference camera (refer to Figure 10 on page 13). SW1 increases vertical phase; SW2 decreases vertical phase.

3.Each time an adjustment is made, switch back and forth between the camera you are adjusting and the reference camera. Repeat this process as many times as necessary until the roll between the cameras is no longer noticeable.

4.Adjust the phase of all other cameras by repeating steps 2 and 3. Always adjust to the reference camera selected in step 1.

NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope to align the vertical sync pulses of the reference camera to the selected camera(s).

BLEMISH DETECTION

If small white or colored spots appear in the video image, one or more pixels on the camera imager may be defective. (This condition is common for both CCD and CMOS imagers.)

DN and CH Series cameras with auto iris lenses automatically detect and correct defective pixels during startup. Video turns on, then off, and then on again. If white or colored spots still appear, you can correct the defective pixels manually.

CH Series cameras with fixed iris lenses do not automatically detect and correct defective pixels. You can correct the defective pixels manually.

To manually correct defective pixels (refer to Figure 10 on page 13):

1.Cover the lens completely. Make sure no light can enter the lens.

NOTE: The mechanical iris lens aperture does not completely block the light.

2.Press and hold button SW3 for one second. The camera will find and correct defective pixels. NOTE: Any defective pixels that cannot be completely corrected may still appear.

3.Release button SW3.

4.Uncover the lens for normal camera operation.

C3428M-A (1/08)

15

Image 15
Contents IS210 Series Camclosure Page Contents Important Safety Instructions Radio and Television Interference Regulatory NoticesDescription Parts ListPrepare Mounting Surface InstallationFixed Mounting Pattern Install Base Without ConduitWith Conduit Removing the Wiring Plug Removing the Conduit Cover Reinstall Camera Module Adjust PositionReplace Cover SW4-2 Backlight Compensation DN/CH Series AdjustmentsSwitch Settings SW4-1 Automatic Gain ControlSW4-5 Auto White Balance/Manual White Balance Auto Iris Level AdjustmentVertical Phase Adjustment SW4-4 FlickerlessBlemish Detection Adjusting Vertical PhaseDAY/NIGHT Operation SW1-3 Interlaced Scanning/Progressive Scanning DW/CW Series Wide Dynamic Range AdjustmentsSW1-1 Video Format SW1-2 Line SyncSW1-7 Digital Slow Shutter SW1-4 Auto White Balance/Manual White BalanceSW1-5 Fluorescent/General SW1-6 General WDR/Maximum WDRSW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Attaching the 2.5 mm Monaural Headphone Plug Service ConnectorGeneral SpecificationsProduct Warranty and Return Information ISO9001