Pelco C3425M-D manual IN-CEILING Installation Fixed CEILING/WALL, Pinch the sides

Page 13

4.Remove an adjacent ceiling tile to access the unit.

5.Connect the video cable/wires:

BNC: Connect the BNC connector from the unit to a mating BNC connector.

UTP: Blue wire = Video +

Gray wire = Video -

6. Connect the power wires.

Voltage

Red Wire

Black Wire

 

 

 

12 VDC

+

Ground

 

 

 

24 VAC

~

~

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

7. Reinstall the adjacent ceiling tile.

IN-CEILING INSTALLATION: FIXED CEILING/WALL

1.

Remove the surface mount ring from the back box (refer to Figure 5 on page 11):

 

 

a.

Place fingers on the circular marks located on the sides of the surface mount ring

.

 

b.

Pinch the sides.

 

 

 

 

c.

Lift and remove the surface mount ring from the back box. Do not discard the surface mount

 

 

ring; it is required to complete the installation.

 

2.

Cut a hole 4 inches (10 cm) in diameter in the ceiling/wall (refer to Figure 8 on page 14).

 

3.

Pull video and power wires through the opening.

 

4.

Connect the video cable/wires:

 

 

BNC: Connect the BNC connector from the unit to a mating BNC connector.

 

 

UTP: Blue wire = Video +

 

 

 

 

Gray wire = Video -

 

5.

Connect the power wires.

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

Red Wire

Black Wire

 

 

 

 

 

 

 

 

 

 

 

12 VDC

+

Ground

 

 

 

 

 

 

 

 

 

 

 

24 VAC

~

~

 

 

 

 

 

 

 

 

 

AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.

NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.

C3425M-D (8/08)

13

Image 13
Contents IS90 Series Camclosure Contents List of Illustrations Radio and Television Interference Regulatory NoticesModels DescriptionIS90B-DNV9 IS90B-DNV9X Parts ListShown Actual Size Removing the Bubble Remove the BubbleSurface Installation CEILING/WALL InstallationUnshielded Twisted Pair UTP Video Ceiling/Wall Installation Removing the Surface Mount Ring from the Back Box IN-CEILING Installation Suspended CeilingCeiling Tile Installation with Surface Mount Ring Pinch the sides IN-CEILING Installation Fixed CEILING/WALLIn-Ceiling Installation to a Fixed Ceiling/Wall Surface Installation 4S Standard Electrical BOXStandard Electrical Box Installation IN-CEILING Installation 4S Deep Electrical BOXDeep Electrical Box Installation Varifocal Lens Zoom and Focus Adjustments Camera AdjustmentsSwitch Settings DN/CH/C Series AdjustmentsAuto Iris Level Adjustment Vertical Phase Adjustment DAY/NIGHT Operation SW1-2 Line Sync DW/CW Series Wide Dynamic Range AdjustmentsSW1-4 AWB Auto White Balance/MWB Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Positioning the Camera Camera PositioningInstalling the Bubble Install Liner and BubbleService Connector Attaching the 2.5 mm Monaural Headphone Plug General SpecificationsProduct Warranty and Return Information ISO9001