DW/CW SERIES (WIDE DYNAMIC RANGE) ADJUSTMENTS

Refer to Figure 14 to adjust the IS90-DW or IS90-CW model.

SW1

R7

DEFAULT SWITCH POSITION

Figure 14. Adjusting the IS90-DW/CW Series Camclosure

SWITCH SETTINGS

Locate the DIP switch. Then set the switches for your installation.

SW1-1: Video Format

Set to ON for NTSC. Set to OFF for PAL. The default is ON.

SW1-2: Line Sync

When multiple cameras are connected to the same switching device, vertical roll may occur on the monitor. AC line lock eliminates vertical roll by locking the frame rate to the power supply frequency. Each camera output is synchronized to the power supply frequency. (Refer to Vertical Phase Adjustment on page 25 for more information.)

Internal line sync disables line lock and synchronizes cameras internally.

Set to ON to use AC line lock. Set to OFF to use internal line sync. The default is ON.

SW1-3: Interlaced Scanning/Progressive Scanning

Interlaced scanning is the standard for analog recording installations. Each frame contains one odd and one even field, each processed separately.

Progressive scanning is better for digital recording installations. Each frame is processed as a whole, which results in less blurring and cleaner digital conversion. It also saves storage space on digital video recorders.

Set to ON to select interlaced scanning. Set to OFF to select progressive scanning. The default is ON.

22

C3425M-D (8/08)

Image 22
Contents IS90 Series Camclosure Contents List of Illustrations Regulatory Notices Radio and Television InterferenceDescription ModelsParts List IS90B-DNV9 IS90B-DNV9XShown Actual Size Remove the Bubble Removing the BubbleSurface Installation CEILING/WALL InstallationUnshielded Twisted Pair UTP Video Ceiling/Wall Installation IN-CEILING Installation Suspended Ceiling Removing the Surface Mount Ring from the Back BoxCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL Pinch the sidesSurface Installation 4S Standard Electrical BOX In-Ceiling Installation to a Fixed Ceiling/WallIN-CEILING Installation 4S Deep Electrical BOX Standard Electrical Box InstallationDeep Electrical Box Installation Camera Adjustments Varifocal Lens Zoom and Focus AdjustmentsDN/CH/C Series Adjustments Switch SettingsAuto Iris Level Adjustment Vertical Phase Adjustment DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-2 Line SyncSW1-4 AWB Auto White Balance/MWB Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Camera Positioning Positioning the CameraInstall Liner and Bubble Installing the BubbleService Connector Attaching the 2.5 mm Monaural Headphone Plug Specifications GeneralProduct Warranty and Return Information ISO9001