DN/CH/C SERIES ADJUSTMENTS
Refer to Figure 12 to adjust the
Figure 12. Adjusting the IS90-DN/CH/C Series Camclosure
SWITCH SETTINGS
Locate the DIP switch. Then set the switches for your installation.
SW4-1: AGC (Auto Gain Control)
The AGC (automatic gain control) adjusts the image automatically to compensate for changes in light levels.
Set to ON to enable AGC. Set to OFF to disable AGC. The default is ON.
SW4-2: BLC (Backlight Compensation)
The BLC (backlight compensation) feature compensates for backlit scenes by enhancing objects in the center of the scene.
Set to ON to enable BLC. Use this setting if a bright backlight is present and the subject in the center of the picture appears dark or as a silhouette.
Set to OFF to disable backlight compensation. This is the default.
SW4-3: Line Sync
When multiple cameras are connected to the same switching device, vertical roll may occur on the monitor. AC line lock eliminates vertical roll by locking the frame rate to the power supply frequency. Each camera output is synchronized to the power supply frequency. (Refer to Vertical Phase Adjustment on page 20 for more information.)
Internal line sync disables line lock and synchronizes cameras internally.
Set to OFF to use AC line lock. Set to ON to use internal line sync. The default is OFF.
18 |