DN/CH/C SERIES ADJUSTMENTS

Refer to Figure 12 to adjust the IS90-DN, IS90-CH, or IS90-C model.

Figure 12. Adjusting the IS90-DN/CH/C Series Camclosure

SWITCH SETTINGS

Locate the DIP switch. Then set the switches for your installation.

SW4-1: AGC (Auto Gain Control)

The AGC (automatic gain control) adjusts the image automatically to compensate for changes in light levels.

Set to ON to enable AGC. Set to OFF to disable AGC. The default is ON.

SW4-2: BLC (Backlight Compensation)

The BLC (backlight compensation) feature compensates for backlit scenes by enhancing objects in the center of the scene.

Set to ON to enable BLC. Use this setting if a bright backlight is present and the subject in the center of the picture appears dark or as a silhouette.

Set to OFF to disable backlight compensation. This is the default.

SW4-3: Line Sync

When multiple cameras are connected to the same switching device, vertical roll may occur on the monitor. AC line lock eliminates vertical roll by locking the frame rate to the power supply frequency. Each camera output is synchronized to the power supply frequency. (Refer to Vertical Phase Adjustment on page 20 for more information.)

Internal line sync disables line lock and synchronizes cameras internally.

Set to OFF to use AC line lock. Set to ON to use internal line sync. The default is OFF.

18

C3425M-D (8/08)

Image 18
Contents IS90 Series Camclosure Contents List of Illustrations Regulatory Notices Radio and Television InterferenceDescription ModelsParts List IS90B-DNV9 IS90B-DNV9XShown Actual Size Remove the Bubble Removing the BubbleInstallation Surface Installation CEILING/WALLUnshielded Twisted Pair UTP Video Ceiling/Wall Installation IN-CEILING Installation Suspended Ceiling Removing the Surface Mount Ring from the Back BoxCeiling Tile Installation with Surface Mount Ring IN-CEILING Installation Fixed CEILING/WALL Pinch the sidesSurface Installation 4S Standard Electrical BOX In-Ceiling Installation to a Fixed Ceiling/WallIN-CEILING Installation 4S Deep Electrical BOX Standard Electrical Box InstallationDeep Electrical Box Installation Camera Adjustments Varifocal Lens Zoom and Focus AdjustmentsDN/CH/C Series Adjustments Switch SettingsAuto Iris Level Adjustment Vertical Phase Adjustment DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-2 Line SyncSW1-4 AWB Auto White Balance/MWB Manual White Balance SW1-8 Day/Night Operation DW models only Auto Iris Level Adjustment Camera Positioning Positioning the CameraInstall Liner and Bubble Installing the BubbleService Connector Attaching the 2.5 mm Monaural Headphone Plug Specifications GeneralProduct Warranty and Return Information ISO9001