5. Connect the power wires.
Voltage  | Red Wire  | Black Wire  | 
  | 
  | 
  | 
12 VDC  | +  | Ground  | 
  | 
  | 
  | 
24 VAC  | ~  | ~  | 
  | 
  | 
  | 
AC operation only: If you are wiring more than one Camclosure to the same transformer, connect one side of the transformer to the red wire on all units; connect the other side of the transformer to the black wire on all units.
NOTE: Failure to connect all AC powered units the same way will cause the cameras to be out of phase with each other and may produce a vertical roll when switching between cameras.
6. Attach the back box to the adapter plate with two supplied 
4S DEEP ELECTRICAL BOX
CEILING/  | 
WALL  | 
ADAPTER PLATE  | ||
(SUPPLIED)  | ||
PHILLIPS PAN  | ||
  | ||
HEAD SCREWS  | 
  | |
(SUPPLIED)  | 
  | |
BACK  | ||
PHILLIPS PAN  | ||
BOX  | ||
HEAD SCREWS  | ||
  | ||
(SUPPLIED)  | 
  | 
Figure 10. 4S Deep Electrical Box Installation
16  |