Rinnai 2424WC manual S I C O P E R a T I O N, Adjusting Temperature

Page 10

B A S I C O P E R A T I O N

1 Adjusting Temperature

The setpoint temperature of the Con- tinuum 2424WC can only be adjusted by the user using the Remote Control. To adjust the setpoint temperature of the Continuum 2424WC, all hot water taps must be closed, and all circulating pumps turned off.

TEMPERATURE CANNOT BE

ADJUSTED WHEN ANY HOT

WATER TAP IS OPEN, OR

WATER IS FLOWING THROUGH

THE WATER HEATER.

Simply press the or button until the required temperature is dis- played on the Digital Monitor.

2

To operate the Continuum 2424WC simply turn any hot water tap on, or initiate water flow through the unit with a circulating pump. This will automatically light the burner providing hot water at the preset temperature. If the optional remote control has been installed, the green IN USE indicator will glow on the remote control.

140°F

The Remote Control will display the water heaters current setpoint temperature.

CHECK LOCAL CODES FOR THE MAXIMUM WATER TEMPERATURE SETTING ALLOWED WHEN USED IN NURSING HOMES, SCHOOLS, DAY CARE CENTERS, AND ALL OTHER PUBLIC USE APPLICATIONS.

Rinnai recommends fixing the water heater setpoint temperature at 108°F for ALL public use applications.

www.rinnaiamerica.com

1 0

Model 2424WC

Image 10
Contents Outdoor unit Specification S REU-2424WC-USLPG Condition and Exceptions R R a N T YWarranty Care & Lime Condition WarningFor the Rinnai Certified Installer nearest you call N E R ’ S I N S TA L L AT I O N I N F O R M AT I O NA T U R E S O F Y O U R N E W C O N T I N U U M F E T YI S S U E S Filter Adjusting Temperature S I C O P E R a T I O NO U T H O T W a T E R A l d s R s tM O T E C O N T R O L O P E R a T I O N Digital MonitorError M E S S a G E S Code Fault Remedy DisplayedI N T E N a N C E & S E R V I C E I N F O R M AT I O N Maintenance Suggestions Must be checked annually for blockage or deteriorationTrouble Shooting and Common Questions Dont have any hot water when I open the tapFor Your Safety Read Before Operating E R a T I N G I N S T R U C T I O N STo Turn Off Gas To Appliance Installer’s Instructions INSTALLER’S Installation Instructions This manual must be followed exactlyN T I N U U M O U T L E T F L O W D a T a Vent termination clearances Minimum DimensionsLocating the unit Eve, porche, or overhang Height 23 3 WidthRecommended Piping for Installation OPTIONALPower Failure Freeze Protection Model 2424WC Model 2424WC Model 2424WC Minimum 7 WC Propane Gas Minimum 10WCModel 2424WC INSTALLER’S Installation Instructions Wiring Diagram Model 2424WC If the Continuum 2424WCfails to light Model 2424WC Base of the unit and connect the wires to the con Thread the cable through the access hole atTrol terminals on the right hand side bottom Hi. fire 59 Lo. fire Diagnostic Points Schematic Diagram Exploded View Cabinet Exploded View Internals Model 2424WC Exploded View Electrical Part Number Parts List Number DescriptionQuantity Parts List Number DescriptionParts List Number Description Part Number Quantity PCBParts List ZAG0514UKModel 2424WC Energy Savers Vent free radiant heaters 99.9% efficient Heat like the sun