INSTALLER’S INSTALLATION INSTRUCTIONS

Testing

1)Turn on the gas and water.

2)Check for water and gas leaks. Use soapy water to test for gas leaks.

3)Remove pressure test point screw, attach pressure gauge to test point.

4)Turn Power on.

5)Open any hot water tap fully.

6)Check test point or supply pressure in water columns per inch.

Manifold Pressure:

 

Supply pressure:

Natural Gas

5.3" Hi. fire

0.43" Lo. fire

Natural Gas

Min. 7" Max. 10.5"

LPG

8.7" Hi. fire

0.59" Lo. fire

LPG

Min. 10" Max. 14"

NOTE: The pressure may be low due to too little flow, too high an incoming tempera- ture, and/or undersized gas piping. Examine these areas before determining that the pressure needs to be adjusted. Contact Rinnai before adjusting manifold pressures at 1-800-621-9419. Failure to contact Rinnai, could void unit’s warranty.

7)If it is determined that the gas pressure needs adjusting, first check the in coming pressure at the test point on the gas inlet. If it is correct follow the adjusting procedure contained in the pouch of the unit EXACTLY. If in doubt call Rinnai 1-800-621-9419.

The regulator is pre-set at the factory, it should not need resetting.

8)Turn the hot water off. Turn the power off. Remove the pressure guage and replace the test point screw. Check for a gas leak around the test point screw.

9)Replace the front cover.

10)Turn the power back on.

11)Check the operation of the unit. Check the operation of each of the remote controls. Check the operation of the Power failure protection system.

12)Explain the proper operation of the Continuum 2424WC to the customer.

www.rinnaiamerica.com

3 6

Model 2424WC

Image 36
Contents Outdoor unit Specification S REU-2424WC-USLPG Condition and Exceptions R R a N T YWarranty Care & Lime Condition WarningFor the Rinnai Certified Installer nearest you call N E R ’ S I N S TA L L AT I O N I N F O R M AT I O NA T U R E S O F Y O U R N E W C O N T I N U U M F E T YI S S U E S Filter Adjusting Temperature S I C O P E R a T I O NO U T H O T W a T E R A l d s R s tM O T E C O N T R O L O P E R a T I O N Digital MonitorError M E S S a G E S Code Fault Remedy DisplayedI N T E N a N C E & S E R V I C E I N F O R M AT I O N Maintenance Suggestions Must be checked annually for blockage or deteriorationTrouble Shooting and Common Questions Dont have any hot water when I open the tapFor Your Safety Read Before Operating E R a T I N G I N S T R U C T I O N STo Turn Off Gas To Appliance Installer’s Instructions INSTALLER’S Installation Instructions This manual must be followed exactlyN T I N U U M O U T L E T F L O W D a T a Dimensions Locating the unit Eve, porche, or overhangVent termination clearances Minimum Height 23 3 WidthRecommended Piping for Installation OPTIONALPower Failure Freeze Protection Model 2424WC Model 2424WC Model 2424WC Minimum 7 WC Propane Gas Minimum 10WCModel 2424WC INSTALLER’S Installation Instructions Wiring Diagram Model 2424WC If the Continuum 2424WCfails to light Model 2424WC Thread the cable through the access hole at Base of the unit and connect the wires to the conTrol terminals on the right hand side bottom Hi. fire 59 Lo. fire Diagnostic Points Schematic Diagram Exploded View Cabinet Exploded View Internals Model 2424WC Exploded View Electrical Parts List Number Description Part NumberQuantity Parts List Number DescriptionParts List Number Description Part Number Quantity PCBParts List ZAG0514UKModel 2424WC Energy Savers Vent free radiant heaters 99.9% efficient Heat like the sun