Rinnai 2424WC manual Thread the cable through the access hole at

Page 35

INSTALLER’S INSTALLATION INSTRUCTIONS

Remote Controls - Installation

1)Determine a suitable location for the control.

2)Make three holes on the wall as shown.

3)Run the cable between the control and the Continuum 2424WC or the control and the other control.

outline of remote

securing screw

wire hole

1 1/16”

3 1/4”

(21/32” dia.)

securing screw

Note: Remote Control Dimensions are:

4 3/4” H x 4 3/4 W” x 1” D

4)Remove the face plate from the remote control, using a screw driver.

5)Connect the cable to the remote control.

6)Mount the control to the wall using the holes drilled in step 2.

Note: If the cable cannot be run in the wall cavity, the plastic knockout should be re- moved from the top or bottom of the control to allow flush mounting with the wall

7)Disconnect the power from the Continuum 2424WC.

8)Remove the cover of the Continuum 2424WC.

9)Remove the plastic cover from the PCB and electrical connections.

DO NOT ATTEMPT TO CONNECT THE REMOTE CON-

 

TROLS WITH THE POWER ON, THERE'S 120 VOLT PO-

 

TENTIAL, NEXT TO THE REMOTE CONTROL CONNEC-

 

TIONS INSIDE THE UNIT. All service and wiring should be

 

performed by a certified installer.

TERMINAL

10) Thread the cable through the access hole at the

CLAMP

base of the unit and connect the wires to the con-

 

trol terminals on the right hand side bottom of the

 

PCB. Note: Connect remote control cable to

 

location labeled “TERMINAL” in the drawing at

 

right.

 

11)Secure the control cable using the clamp provided.

12)Replace plastic cover over PCB and then replace the cover of the Continuum 2424WC.

Model 2424WC

3 5

800-621-9419

Image 35
Contents Outdoor unit REU-2424WC-US Specification SLPG R R a N T Y Condition and ExceptionsCare & Lime Condition Warning WarrantyN E R ’ S I N S TA L L AT I O N I N F O R M AT I O N For the Rinnai Certified Installer nearest you callA T U R E S O F Y O U R N E W C O N T I N U U M F E T YI S S U E S Filter S I C O P E R a T I O N Adjusting TemperatureA l d s R s t O U T H O T W a T E RDigital Monitor M O T E C O N T R O L O P E R a T I O NCode Fault Remedy Displayed Error M E S S a G E SI N T E N a N C E & S E R V I C E I N F O R M AT I O N Must be checked annually for blockage or deterioration Maintenance SuggestionsDont have any hot water when I open the tap Trouble Shooting and Common QuestionsE R a T I N G I N S T R U C T I O N S For Your Safety Read Before OperatingTo Turn Off Gas To Appliance Installer’s Instructions This manual must be followed exactly INSTALLER’S Installation InstructionsN T I N U U M O U T L E T F L O W D a T a Height 23 3 Width DimensionsLocating the unit Eve, porche, or overhang Vent termination clearances MinimumRecommended Piping for Installation OPTIONALPower Failure Freeze Protection Model 2424WC Model 2424WC Model 2424WC Propane Gas Minimum 10WC Minimum 7 WCModel 2424WC INSTALLER’S Installation Instructions Wiring Diagram Model 2424WC If the Continuum 2424WCfails to light Model 2424WC Trol terminals on the right hand side bottom Thread the cable through the access hole atBase of the unit and connect the wires to the con Hi. fire 59 Lo. fire Diagnostic Points Schematic Diagram Exploded View Cabinet Exploded View Internals Model 2424WC Exploded View Electrical Quantity Parts List Number DescriptionPart Number Description Parts List NumberPCB Parts List Number Description Part Number QuantityZAG0514UK Parts ListModel 2424WC Vent free radiant heaters 99.9% efficient Heat like the sun Energy Savers