INSTALLER’S INSTALLATION INSTRUCTIONS
This manual must be followed exactly.
1)Read the safety issues completely before installing the Continuum 2424WC.
2)This water heater is suitable for water (potable) heating or space heating.
-The piping connected to the Continuum 2424WC must be approved for use in potable water systems.
-Toxic chemicals such as those used for boiler water treatment are NOT to be introduced to the Continuum 2424WC.
-The Continuum 2424WC, if it will be used as a potable water source, it must not be connected to a system that was previously used with a nonpotable water heating appliance.
3)The Continuum 2424WC is not suitable for use as a pool or spa heater.
4)The dip switches on the computer board have been preset at the factory and should not be readjusted without the express knowledge and involvement of Rinnai.
5)Install the Continuum 2424WC outdoors only.
6)Maintain proper space around the unit for proper servicing and operation. Minimum clearances from combustible materials are listed below.
Top of Heater | 12 | inches |
Back of Heater | 0 | inch |
Front of Heater | 24 | inches |
Sides of Heater | 6 | inches |
Ground | 12 | inches |
DO NOT install the Continuum 2424WC under an overhang less than 3 feet from the top of the unit. The area under any overhang greater than 3 feet must be open on three sides.
7)Installer must install a Pressure relief valve. Pipe pressure relief discharge to a drain or outside environment (see page 29).