INSTALLER’S INSTALLATION INSTRUCTIONS

-Warnings-

This manual must be followed exactly.

1)Read the safety issues completely before installing the Continuum 2424WC.

2)This water heater is suitable for water (potable) heating or space heating.

-The piping connected to the Continuum 2424WC must be approved for use in potable water systems.

-Toxic chemicals such as those used for boiler water treatment are NOT to be introduced to the Continuum 2424WC.

-The Continuum 2424WC, if it will be used as a potable water source, it must not be connected to a system that was previously used with a nonpotable water heating appliance.

3)The Continuum 2424WC is not suitable for use as a pool or spa heater.

4)The dip switches on the computer board have been preset at the factory and should not be readjusted without the express knowledge and involvement of Rinnai.

5)Install the Continuum 2424WC outdoors only.

6)Maintain proper space around the unit for proper servicing and operation. Minimum clearances from combustible materials are listed below.

Top of Heater

12

inches

Back of Heater

0

inch

Front of Heater

24

inches

Sides of Heater

6

inches

Ground

12

inches

DO NOT install the Continuum 2424WC under an overhang less than 3 feet from the top of the unit. The area under any overhang greater than 3 feet must be open on three sides.

7)Installer must install a Pressure relief valve. Pipe pressure relief discharge to a drain or outside environment (see page 29).

www.rinnaiamerica.com

2 0

Model 2424WC

Image 20
Contents Outdoor unit Specification S REU-2424WC-USLPG Condition and Exceptions R R a N T YWarranty Care & Lime Condition WarningFor the Rinnai Certified Installer nearest you call N E R ’ S I N S TA L L AT I O N I N F O R M AT I O NA T U R E S O F Y O U R N E W C O N T I N U U M F E T YI S S U E S Filter Adjusting Temperature S I C O P E R a T I O NO U T H O T W a T E R A l d s R s tM O T E C O N T R O L O P E R a T I O N Digital MonitorError M E S S a G E S Code Fault Remedy DisplayedI N T E N a N C E & S E R V I C E I N F O R M AT I O N Maintenance Suggestions Must be checked annually for blockage or deteriorationTrouble Shooting and Common Questions Dont have any hot water when I open the tapFor Your Safety Read Before Operating E R a T I N G I N S T R U C T I O N STo Turn Off Gas To Appliance Installer’s Instructions INSTALLER’S Installation Instructions This manual must be followed exactlyN T I N U U M O U T L E T F L O W D a T a Dimensions Locating the unit Eve, porche, or overhangVent termination clearances Minimum Height 23 3 WidthRecommended Piping for Installation OPTIONALPower Failure Freeze Protection Model 2424WC Model 2424WC Model 2424WC Minimum 7 WC Propane Gas Minimum 10WCModel 2424WC INSTALLER’S Installation Instructions Wiring Diagram Model 2424WC If the Continuum 2424WCfails to light Model 2424WC Trol terminals on the right hand side bottom Thread the cable through the access hole atBase of the unit and connect the wires to the con Hi. fire 59 Lo. fire Diagnostic Points Schematic Diagram Exploded View Cabinet Exploded View Internals Model 2424WC Exploded View Electrical Quantity Parts List Number DescriptionPart Number Parts List Number DescriptionParts List Number Description Part Number Quantity PCBParts List ZAG0514UKModel 2424WC Energy Savers Vent free radiant heaters 99.9% efficient Heat like the sun