INSTALLER’S INSTALLATION INSTRUCTIONS
Electrical Connection Notes
WARNING: The Continuum 2424WC must be electrically grounded in accor- dance with local codes or in the absence of local codes with the most re- cent edition of the National Electrical Code, ANSI/NFPA 70. In Canada, all electrical wiring to the Continuum 2424WC should be in accordance with local codes and the Canadian Electrical Code, CSA C22.1 Part1. Do not rely on the gas or water piping to ground the metal parts of the water heater.
CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify correct operation after servicing.
1The Continuum 2424WC requires 120VAC/60 HZ. Power from a properly grounded circuit, GFI.
2An on/off switch must be provided and installed for the incoming 120VAC power.
3Wire the Continuum 2424WC exactly as shown in the wiring diagram on the next page and on the inside of the cover panel. The blue wire is the hot leg wire; the brown wire is the neutral wire.
4A green screw is provided in the junction box for the grounding connection.
Ground
ON/OFF
Your disconnect switch should be a type that is suitable for outdoor use. Check National Electrical Codes for proper type switch to use in your area.