Rinnai 2424WC manual Lpg

Page 3

S P E C I F I C A T I O N S

 

Appliance - AC 120 Volts - 60Hz.

 

 

 

Remote control DC 12 Volts (Digital)

 

 

 

 

 

 

 

Flame failure - Flame rod

 

 

 

 

 

 

 

Boiling protection - 203°F

 

 

 

 

 

 

 

Remaining flame (OHS) 194°F bi-metal switch

 

 

 

 

 

Safety devices

Thermal fuse 279°F

 

 

 

 

 

 

Automatic frost protection - Bi metal sensor & anti-frost heaters

 

 

 

 

 

Combustion fan rpm check - Integrated circuit

 

 

 

 

 

 

Over current - Glass fuse (3 amp)

 

 

 

 

 

 

If remote fails or becomes disconnected unit defaults to 100°F with water

 

flowing, this is an anti-scald feature.

 

 

 

 

 

 

 

Remote control

MCC-45-3 US

Main control

 

 

 

 

 

 

Remote control cable

Non-polarized two core cable

 

 

 

 

 

 

 

 

Top of heater

12"

 

 

 

 

 

 

 

 

Front of heater

24"

 

 

 

 

 

 

 

Clearances from combustibles

Sides of heater

6"

 

 

 

 

 

 

 

Back of heater

0"

 

 

 

 

 

 

 

 

 

 

 

 

Ground

 

12"

 

 

 

 

 

 

 

Below eaves, porches, overhangs = 36"

 

 

 

 

Minimum and Maximum gas supply pressure

Natural Gas : *Minimum 6" W. C.

Propane Gas: *Minimum 10" W. C.

(NAT.)

**Maximum 10.5" W. C.

(LPG)

**Maximum 14" W. C.

 

 

 

 

 

Manifold Gas Pressure

Natural Gas

5.3" W. C. high fire

 

0.43" W. C. low fire

LPG:

 

8.7" W. C. high fire

 

0.59" W. C. low fire

 

 

 

 

 

 

Warranty

Five years heat exchanger / five years parts (see unit's warranty for details)

 

 

 

 

 

 

*Minimum input pressure is for the purpose of input adjustments. **Do not exceed maximum pressure.

Model 2424WC

3

800-621-9419

Image 3
Contents Outdoor unit REU-2424WC-US Specification SLPG R R a N T Y Condition and ExceptionsCare & Lime Condition Warning WarrantyN E R ’ S I N S TA L L AT I O N I N F O R M AT I O N For the Rinnai Certified Installer nearest you callA T U R E S O F Y O U R N E W C O N T I N U U M F E T YI S S U E S Filter S I C O P E R a T I O N Adjusting TemperatureA l d s R s t O U T H O T W a T E RDigital Monitor M O T E C O N T R O L O P E R a T I O NCode Fault Remedy Displayed Error M E S S a G E SI N T E N a N C E & S E R V I C E I N F O R M AT I O N Must be checked annually for blockage or deterioration Maintenance SuggestionsDont have any hot water when I open the tap Trouble Shooting and Common QuestionsE R a T I N G I N S T R U C T I O N S For Your Safety Read Before OperatingTo Turn Off Gas To Appliance Installer’s Instructions This manual must be followed exactly INSTALLER’S Installation InstructionsN T I N U U M O U T L E T F L O W D a T a Height 23 3 Width DimensionsLocating the unit Eve, porche, or overhang Vent termination clearances MinimumRecommended Piping for Installation OPTIONALPower Failure Freeze Protection Model 2424WC Model 2424WC Model 2424WC Propane Gas Minimum 10WC Minimum 7 WCModel 2424WC INSTALLER’S Installation Instructions Wiring Diagram Model 2424WC If the Continuum 2424WCfails to light Model 2424WC Thread the cable through the access hole at Base of the unit and connect the wires to the conTrol terminals on the right hand side bottom Hi. fire 59 Lo. fire Diagnostic Points Schematic Diagram Exploded View Cabinet Exploded View Internals Model 2424WC Exploded View Electrical Parts List Number Description Part NumberQuantity Description Parts List NumberPCB Parts List Number Description Part Number QuantityZAG0514UK Parts ListModel 2424WC Vent free radiant heaters 99.9% efficient Heat like the sun Energy Savers